User's Manual

To control the fan and lights from two
locations (a three-way circuit), use two
W-74 wall controls.
1. Remove the screws and switch plate from
the existing switch box and the screws
holding the switch in the switch box.
2. Pull the existing switch from the switch
box to expose the wire connections.
3. Determine which wire is connected to the
common terminal from the power source
(120V AC) of the three-way switch. (The
terminal will be marked on switch).
4. Remove the wire from the common
terminal of the three-way switch.
Connect this wire to the remaining
black/white striped wire on the W-74
control. Secure this splice with a wire
nut.
5. Remove the two remaining wires
from the three-way switch. Connect
the black wire of these wires to
a black wire on the W-74 control.
Secure the splice with a wire nut.
The remaining red wire is to be
connected to the other red wire on the
W-74. Secure the splice with a wire
nut.
6. Connect the green ground wire coming
from the back of the W-74 control to the ground wire in the switch box. Secure the
splice with a wire nut.
7. Check your work by using the wiring diagrams as shown in Figure #5 on this page.
8. Install the W-74 in the wall box with the two long screws provided.
9.Install the wall plate with the two short color-matched screws provided.
10.Installation of the second W-74 control is identical. Repeat steps 1 through 9.
W-74 WALL CONTROL
INSTALLATION
(For use on product with BOTH UP and DOWN LIGHTS ONLY)
Setting the Frequency
DIP SWITCHES
(FIGURE #2)
To use this switch with an existing W-74 wall switch,
you must rst set the jumpers on the new switch to
match that of the existing one.
1. Turn off power to the existing wall switch.
2. Using a screw driver, remove the (2) wall plate
screws, then remove the (2) switch mounting
screws.
3. Gently remove the existing wall switch from the
wall and locate the dip switches located on the
side of the switch.
4. Change the dip switches on the new wall switch
to match the exisiting. (FIGURE 2)
5. Reinstall the existing wall switch.
inStalling the Wall control
The wall control installs in the same manner as an ordinary light switch, using an existing
wall box and wiring. This controller is designed to signal the fan microcomputer as well
as perform normal switching operations. For this reason the following precautions must
be observed:
1. Use only the Casablanca W-74 wall control.
2. Do not use any additional control with your Direct-Touch™ fan (for example, dimmer,
or fan speed control).
3. Do not use more than one fan per wall control.
4. No other light xtures or electrical appliances may be connected on the circuit con-
trolled by the W-74 wall control.
SINGLE W-74 INSTALLATION
CAUTION!
Ensure power is turned OFF at the breaker or fuse panel before starting
installation.
If you have multiple Direct-Touch
fans,
refer to the section "Channel Changing".
1. Remove the screws and switch plate
from the existing switch box.
2. Remove the screws holding the switch
in the switch box.
3. Pull the existing switch from the switch
box to expose the wire connections.
4. Remove the two wires from the switch.
5. Connect the BLACK wire from the
POWER SOURCE that you just removed
from the switch to the BLACK/WHITE
STRIP wire on the W-74 wall control. Secure this connection with a wire nut.
6. Connect the second BLACK wire that
you just removed from the switch to
the second BLACK wire on the located
on the back of the W-74 wall control.
Secure this connection with a wire nut.
7. Connect the green ground wire coming
from the back of the W-74 control to the
ground wire in the switch box. Secure
the splice with a wire nut.
NOTE: The RED wire is not used in
this application. DO NOT remove the
crimped cap from the wire.
8. Check your work by using the wiring
diagrams as shown in Figure #3.
9. Install the W-74 in the wall box with the two long screws provided.
10. Install the wall plate with the two color-matched screws.
DUAL W-74 INSTALLATION
To control the fan and lights from two locations (a three-
way circuit), use two W-74 wall controls as shown in
the wiring diagram in Figure #5. Before installing
the two switches into the wall, place both switches
side by side, then locate the 4 dip switches on the
side of the two switches. Then make sure that the
dip switches are set to the same address on both
switches as shown in Figure #4. When setting these
dip switches you are setting the channel number
that is required to control both your fan and lights
from both sides of the room. If you are installing
other Direct-Touch™ fans within your home you
may need to reset the dip switches on these other
fans to a different channel before installing your
W-74 wall control into the wall. Please review the
section on channel changing on this instruction
sheet.
channel changing
Each fan must operate on it’s own frequency to prevent interference. Fan frequencies
are set by the dip switch settings on the W-74 wall control (other than to match an
existing W-74 controlling the same fan). To synchronize the fan to the new frequncy:
1. Turn the power OFF to the fan and W-74 you want to synchronize.
2. Turn the power back on to the fan and W-74 wall control.
3. Within 20 seconds of restoring power to the ceiling fan and the W-74 Wall Control
press and hold both the “1” and
1 2
0
4 3
reverse buttons. For 3 seconds, you will hear
one tone from the Piezo Buzzer indicating the command has been accepted. The
Fan and Lights will be off.
CAUTION!
Ensure power is turned OFF at the breaker or fuse panel before starting
installation.
W-74 Wall control HardWare
Wall Plate
Screws (2)
Switch
Mounting
Screws (2)
(4) Wire Cap
W-74
Wall Control
Cover Plate
WARNING!
To avoid possible electrical shock, make
certain that electricity is turned off at
the circuit breaker or fuse box before
attempting any installation or repair
procedure
CAUTION! NOT turning the power
OFF at the circuit breaker or fuse box
may cause damage to the electronics
within the wall control and or the PC
board on the fan.
W-74 Wall control PreParation
Circuit Breaker
(Trip breaker for the
circuit you will be
working on)
Fuse Box
(Remove fuse for the
circuit you will be
working on)
BLACK AND WHITE
STRIPED WIRE
2 BLACK
WIRES
RED WIRE
NOT USED
(FiGUre #3)
(FIGURE #4)
DIP SWITCHES
BLACK
BLACK
RED
GREEN
120V AC
BLACK
BLACK WITH
WHITE STRIPE
W-74
RED
RED
RED
BLACK WITH
WHITE STRIPE
GREEN
W-74
BLACK
BLACK
BLACK
BLACK
BLACK
NEUTRAL
WHITE
GREEN
(FIGURE #5)
W-74
Wall Control
BLACK AND WHITE
STRIPED WIRE
2 RED WIRES
2 BLACK
WIRES
(FIGURE #6)
W-74
Red
White
Blue
Black/White