USER’S MANUAL ATTACHMENT F
Road Weigher ----------------------------------------------- RW-2601PRF ----------------------------------------------- Owner's Manual Federal Commission Communications Requirements
Warning : Changes or modifications not expressly approved by the party responsible for compliance with the FCC’S rules could void the user's authority to operate the equipment. NOTE : This equipme nt has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
* * * 1. Preface 2. Features Contents * * * ••••••••••••• 1 ••••••••••• 2 3. Specifications •••••••••••• 6 ∅ Dimensions ∅ Specifications 4. Front Panel ••••• 5. Test Mode ••••••• 6. Calibration Mode Error 11 ••••••• 8. Weighing Mode 9. 8 ••••••••• 7. Set Mode Message and 7 13 ••• 16 Trouble ••• 18 1. Preface We greatly appreciate for your purchase of the CAS RW2601PRF .
These goods have hold excellent performance and splendid properties through strike tests as well as devoting ourselves under severe quality management. Before using RW-2601PRF, it is recommended to read this manual carefully and to apply the function application fully. Cautions ! Do not press the keys hardly, for the keys are in operation with soft touch. ! Keep away RW-2601PRF from the rain. ! Avoid sudden temperature change.
Specifications ITEM Description Operating Power Inner Battery Operation.(DC6V) Power AC 120V, 60 Hz (For Battery Charger) Source Display LCD 6 Digit (25 mm) Sub display Stable, Zero, Net Product Weight 9.2 kg Option Built -in Printer Frequency 903.000Mhz < 918.500Mhz Communication method FSK (Frequency Shift Keying fsk) Comm. speed 9600bps Comm. distance Max. 100M Display below zero “-” display Battery life time Approx. 20 hours Battery charging time Approx.
4. Front Panel (1) Display Lamp STABLE NET ZERO POWER CHARGE : Ωειγητ ισ σταβλε : ΟΝ (νετ ωειγητ), ΟΦΦ (γροσσ ωειγητ) ZERO TARE Static Motion kg lb SUM PRINT TRUCK No. ENTER : “0” κγ : Supply AC POWER SOURCE. : Green Lamp -> Charging is completed. Red Lamp -> It is charging. (2) Key Functions ϒ Numeric keys - TEST, CAL, SET Mode :Used to enter numerical data.
- Used as an ENTER key. (3) How to go to TEST mode ϒ Press the Truck no. key and ON/OFF key. (4) How to go to SET mode ϒ Press the ENTER key and ON/OFF. (5) How to go to CAL mode ϒ Turn on the power while pressing the ZERO key and then press the TARE key within 1 second. 5.TEST MODE (1) How to go to Test mode Press the Truck no. key and ON/OFF key. (2) Key Functions Numeric key : Used to enter numerical data. ENTER key : Used to go to next menu.
Key Test Key ENTER key : Next menu Other key : Perform test Display Descriptions tESt1 1 Press any code of displayed. key to test then the key is TTEESSTT Display Test Key ENTER key: Next menu Display tESt2 88888 Descriptions Test 2 automati ally is performed REF 1. You will go to TEST 3 automatically after completing TEST 2. TTEESSTT A/D Conversion Test (Load Cell Test) Key ENTER key: Next menu Display Descriptions tESt 3 Display 5500 ofcurrent shows digital value weight.
TEST OK
6. CALIBRATION MODE (1) How to go to Calibration Mode Turn on the power while pressing the ZERO key and then press the TARE key within 1 second. (2) Key Functions Numeric key : Used to enter numerical data. ENTER key : Used to go to next menu.
Set Up Maximum Capacity 1 < 99,999 kg Display RANGE ---> Key Numeric key : Increase or decrease the number CAL 1 100 10000 ENTER key : Save and Descriptions 100 kg 10000 kg REF 1. The maximum capacity means the maximum weight that scale can measure. CCAALL 22 Set Up Minimum Division RANGE ---> Key 0.0005 < 100 kg Display key : Input the next division. ( 0.001 < 50 ) ENTER key : Save and CAL 2 1 0.01 Descriptions 1 kg 0.01 kg REF 1. The minimum division means the value of one division. REF 2.
Zero Calibration Key Display ENTER key: Zero calibration and go to next menu. Descriptions CAL 4 Remove the weight from the and press the ENTER UnLoAd platter key -----Under zero calibration GOOD Zero calibration is completed. REF 1.If zero calibration is done without any error, GOOD message is displayed and you can go to CAL 5 automatically. REF 2.If you want to finish CAL mode, press the SET key calibration.
(3) Set Menu (F4 ~ F14) F04 F08 F12 F13 F14 : : : : : Digital filter Automatic Back-light RF channel The number of platform Option clock Designation of the velocity change on weight. Automatic Back-light 1 : Less 01 Manual Back-light Adjust the set Vibration ~ according ~ 1 Automatic Back-light 9 : Much to the condition.
How to set up date/time (Ex.
8. Weighing Mode (1) How to go to Weighing Mode Press the ON/OFF key. (2) Operations Key Usage Numeric Key: 1,2,3,4,5,6...0 key Used to select where to locate each alphabet or digit. ex) Press "3" key, the display shows t3. (It means that you can enter third character of truck number) ℵ∂ Key :The right arrow key is for when used from A to next alphabet, and the left arrow key is for in the reverse direction.
1) How to enter Truck No. You can enter up to 8 digit for truck number. If you want to enter AB123 for truck number, follow next steps. KEY Truck No. key ∂ key "2" key ∂ key ∂ key "3" key ″ key "4" key ″ key ″ key "5" key ″ key ″ key ″ key ENTER key LCD screen t1 t1 t2 t2 t2 t3 t3 t4 t4 t4 t5 t5 t5 t5 A A B 1 1 2 1 2 3 Explanation t1: first character First character is A t2: second character. Second character is B. t3: third character.
(1) Normal Mode RFErr ≤ Reason for error When RW-2601P can't communicate with RW-P in 5 seconds When RW-P has any problem. Treatment After check F12,F13, Turn off and then on. Err 06 ≤ Reason Error in printer connection Trouble shooting Check the printer connector If there is no problem with printer connector, call your CAS dealer. Err 08 ≤ Reason ZERO or TARE key does not work because weight is not stable. Trouble shooting When the weight is stable press the ZERO or TARE key.
Over ≤ Reason Weight is exceed maximum capacity of the scale. Trouble shooting Do not exceed the weight limit. If the load cell is damaged, the load cell should be replaced. (2) CAL MODE Err 21 ≤ Reason The resolution is set to be exceeded the limit 1/30,000. Trouble shooting Lower the resolution. The resolution = Maximum weight/one division Modify the maximum weight in CAL1 or modify the division in CAL2 so that the resolution should be below 1/30,000.