DRYVIEW 6850 Laser Imager Safety Manual
150 Verona Street Rochester, New York 14608 © Carestream Health, Inc., 2010 CARESTREAM and DRYVIEW are trademarks of Carestream Health, Inc. Pub No. 2G8646 Rev.
Table of Contents Safety and Related Information Safety, Warnings, and Cautions .....................................................................................................1 Safety Labels .............................................................................................................................5 Safety and Health Compliance .....................................................................................................11 Safety.................................................
Safety and Related Information Safety, Warnings, and Cautions Please read and understand all instructions before using this product. RISK OF ELECTRIC SHOCK: This equipment is operated with hazardous voltage which can shock, burn, or cause death. • Remove wall plug before servicing equipment. Never pull on cord to remove from outlet. Grasp plug and pull to disconnect. Do not attempt to service or repair the laser imager yourself to avoid exposure to dangerous voltage, laser beam, or other danger.
Safety and Related Information DANGER: THIS EQUIPMENT IS NOT CONTAINED IN A SEALED CABINET. DO NOT USE THIS EQUIPMENT IN LOCATIONS WHERE IT CAN COME IN CONTACT WITH LIQUIDS, INCLUDING BODY FLUIDS. CAUTION: Do not use a cell phone within 2 meters of a laser imager. This proximity includes any imager behind a wall adjacent to your location. CAUTION: Do not use a microwave oven within 4 meters of a laser imager.
Safety and Related Information CAUTION: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Safety and Related Information unless their community offers a battery collection program. In other regions, contact local or regional solid waste authorities for proper disposal guidance. LASER WARNING: The equipment uses an invisible laser with a maximum power of 120 milliwatts. Laser radiation may be present when the machine operates without the rear cover installed. Covers with this label may only be removed by an Authorized Service Provider of Carestream Health, Inc. products.
Safety and Related Information Safety Labels Safety labels are attached to the laser imager in compliance with international standards. English Text on Labels Some names on the labels are shortened and left in English.
Safety and Related Information Symbol on label Definition Tension Drive Belt Lower Drive-Roller Belt Main Drive Belt Cooling Roller Drive Belt Processor Belt Path Short Drive Belt Cooling Section Drive Belt Long Drive Belt Drum Drive Belt 6 2G8646 2010-11-04
Safety and Related Information Labels - Locations and Details DryView Laser Imager DryView 6800 August 2007, 2007 08 100/120/200/220/240V 68000501 12/12/7/7/7A 7F2301 50/60Hz 6551576 311346 3JZT Carestream Health, Inc. Rochester, NY 14608 TM: DryView 7F3118.E This label shows the serial number and model number of the Imager along with other important data items. Laser Radiation Warning Labels 2010-11-04 1 Class 3B invisible laser radiation.
Safety and Related Information Laser Specifications Type Scanning (moving) laser beam emitting from a diode Wavelength 810 +/- 10 nanometers Maximum power 120 milliwatts Beam divergence from Laser Diode Minimum: 6.8 degrees, maximum: 32 degrees ! 8E4621.E 8E4621.E ! High Voltage Warning Label This warning label indicates that high voltage is present under panels or enclosures where labels are attached.
Safety and Related Information 1 3 4 2 5 Agency Statements 2010-11-04 1 Product Label. This label states that the imager is a Laser Imaging Printer. 2 Grounding Reliability. This label states that grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked "Hospital Only" or "Hospital Grade." 3 Agency Symbols and Class 1 Laser Safety. High voltage: Indicates that high voltage is present under panels where the label is attached.
Safety and Related Information 1 B 8F41 2 3 8F3563 .31 3 4 4 Hot Surface Labels 10 1 Drum end cap hot surface. This label indicates to use care near the processor drum end cap to avoid possible burns. 2 Drum hinge hot surface. This label indicates to use care near the processor drum hinge to avoid possible burns. 3 Drum hot surface. This label advises to use care near the processor drum to avoid possible burns. 4 Processor flatbed hot surface.
Safety and Related Information Safety and Health Compliance This equipment has been tested for and complies with the following Safety and Emissions Standards. Certificates of Compliance and Declarations of Conformity have been issued as shown below. Safety United States 21 CFR 900.12(e) Mammography Quality Standards Act; Quality Standards; Quality Assurance for Equipment. FDA 21CFR 807 Subpart E - Premarket Notification Procedures. 21 CFR 1040.
Safety and Related Information EMC United States FCC Rules and Regulations, Title 47, Part 15, Subpart B, Class A: Radio Frequency Devices: Unintentional Radiators. This equipment has been tested and been found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules. Those limits are designed to provide reasonable protection against harmful interference in a residential installation.
Safety and Related Information Europe and the Rest of World Guidance and Manufacturer’s Declaration for Electromagnetic Emissions The DRYVIEW 6850 Laser Imaging System is intended for use in the electromagnetic environment specified below. The customer or user of the 6850 Laser Imager should ensure that it is used in such an environment. Emissions Test Compliance Electromagnetic Environment - Guidance RF emissions: Group 1 The 6850 Laser Imager uses RF energy only for its internal function.
Safety and Related Information Guidance and Manufacturer’s Declaration for Electromagnetic Immunity The 6850 Laser Imager is intended for use in the electromagnetic environment specified below. The customer or user of the Laser Imager should ensure that it is used in such an environment.
Safety and Related Information Guidance and Manufacturer’s Declaration for Electromagnetic Immunity The 6850 Laser Imager is intended for use in the electromagnetic environment specified below. The customer or user of the 6850 Laser Imager should ensure that it is used in such an environment.
Safety and Related Information Guidance and Manufacturer’s Declaration for Electromagnetic Immunity Note 1 Field strengths from fixed transmitters, such as base station for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
Safety and Related Information EU Directives 93/42/EEC Title: Council Directive Concerning Medical Devices. 1999/5/CE Title: Council Directive Concerning Radio Equipment and Telecommunications Terminal Equipment. Recycling Label In the European Union, this symbol indicates that when the last user wishes to discard this product, it must be sent to appropriate facilities for recovery and recycling. Contact your local authorized representative for additional information.
Safety and Related Information Please Note The information contained herein is based on the experience and knowledge relating to the subject matter gained by Carestream Health, Inc. prior to publication. No patent license is granted by this information. Carestream Health, Inc. reserves the right to change this information without notice and makes no warranty, express or implied, with respect to this information. Carestream Health, Inc.
150 Verona Street Rochester, New York, 14608 © Carestream Health, Inc., 2010 CARESTREAM and DRYVIEW are trademarks of Carestream Health, Inc. Pub No. 2G8646 Rev.