8 Monitor & Configuration– SNMP
Following are the SNMP settings and commands. The IP address and the general settings. Need to be known in order to
access the unit.
SWNMP discovery tool can be used. See section
8.1 SNMP General Configuration
Before starting to work with the unit via SNMP, it needs to be configured according to your NMS requirements.
Configuring the SNMP setting:
• Version – SNMP version: V1&V2 or V3
• Read Only Community – Read only community name
• Read/Write Community – Read/Write community name
• Trap version – versions - V1 or V2
• Trap Host 1 – IP of trap host 1
• Trap Community 1 – name of trap host 1 community
• Trap Host 2 – IP of trap host 2
• Trap Community 2 – name of trap host 2 community
8.2 SNMP Commands (MIB)
MIB files are delivered with the SW version. There are 3 NBX specific command files:
• CAPACICOM-COMMON.mib – basic capacicom product commands (e.g., Software upgrade)
• CAPACICOM-NBX.mib - specific NBX R1000-RF commands (e.g., IoT RF settings)
• CAPACICOM-ROOT.mib – link to the global mib tree
Detailed commands are described within the mib files.