6.4.2 IoT - TX Policy
Selects the transmission power. The R1000-RF uses multi-carrier transmission mode, which enables higher capacity with
minimal interference and adheres to the regulations.
The UL power level must be set to balance enough base stations receiving the repeated messages without reaching too
many.
UL Tx-power [dBm]: Power per transmitted UL frame. Actual power will be calculated based on multi-carrier scenario.
DL Tx-power [dBm]: DL frame transmitted power. The DL TX power is recommended to be set to 27dBm for the DL
link budget to match the UL sensitivity.
Limit UL Max Frames In Block: Allows to limit the maximum UL frames per transmission to a value less or equal to the
Max UL Frames In Block). For example, the user can change this value from 12 to 1. In this case if 12 UL frames are
received simultaneously, they will be transmitted 1 frame at a time.
Max UL Frames In Block: The maximum number of UL frames, calculated according to the UL Tx-power (information
only).