User's Manual

28
RC zone:
Selects the RC zone : RC1,RC2…RC7
The UL and DL center frequencies are specified after selecting the RC. The other characteristics per RC will be
implemented (e.g. 100Hz /600Hz baud etc.).
RF setting:
The NBX-R1000-RF includes two RF channels (A&B) with external antennas. Currently, the Internal Connectors are not
being used.
Each channel has an optional LNA which can be selected (this is for increased sensitivity).
LNA can be turned off if devices are in close proximity to the NBX, e.g. several meters distance from the repeater.
RX Filter:
There are embedded RF filters which can mitigate RF noise in adjacent frequencies (similar to the cavity filter
functionality). Normally those filters should be used. Only in an isolated/quite places those filters can be turned off (for
having an extra sensitivity).