HD-TVI / Network tester User’s Manual (AIVO-35T)
Thank you for purchasing AIVO-35T All-in-one tester. Please read the manual thoroughly before use AIVO-35T All-in-one tester for the first time. Please read the「Safety Information」section in the manual carefully. Please keep the manual in safe place for the future reference. Keep the S/N label for the future RMA purpose. Product without S/N label will be charged for RNA repair service. If there is any question or problem using AIVO-35T All-in-one tester, please contact AIVO technical support.
Content 1. Safety information ----------------------------------------------------------------------------------------------------- 1 2. IP Camera Tester Introduction --------------------------------------------------------------------------------------- 2 2.1 General --------------------------------------------------------------------------------------------------------- 2 2.2 Features -------------------------------------------------------------------------------------------------------- 3 2.
3.3.16 Calculator ---------------------------------------------------------------------------------------- 62 3.3.17 Browser ------------------------------------------------------------------------------------------ 62 3.3.18 IP camera viewer ------------------------------------------------------------------------------- 63 3.3.19 DC12V power output -------------------------------------------------------------------------- 65 3.3.
1 Safety information The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc. ◆ To prevent the functional decline or failure, the product should not be sprinkled or damped. ◆ The exposed part of the tester should not be touched by the dust and liquid.
◆ Never connect the meter with any voltage source while the function switch is in the current, resistance, capacitance, diode, continuity, otherwise it will damage the meter. ◆ Never perform capacitance measurements unless the capacitor to be measured has been discharged fully. ◆ Never measure any of resistance, capacitance, diode or continuity measurements on live circuits. Visual laser sources When you turn on visual laser sources, please don’t stare at it, or will damage to eyes.
2.2 Features 3.5inch 480×320 touch screen, easy to operate. ONVIF IP camera video testing. Compatible with H.264/MPEG4/MJPEG IP cameras, such as Dahua, HIKVISION, and ACTI. Customized service is available. Built in Wi-Fi: receives video from wireless cameras or ONVIF cameras connected to the network.
Optional ) Enhanced Color bar generator: PAL/NTSC multi-system color bar video generator (Eight-system switchable, transmit/receive eight-system colorful images). Cable tracer by sending an audio signal, enables the blue cable tracer to find the connected cable from a bundle of cables.
2.3 Function 2.3.1 Touch screen and OSD menu The IP camera tester combines touch screen control and physical buttons. This combination makes the tester very user friendly. The test meter allows you to move the function icons from the tester’s main menu to the APPS tool folder or move them back to customize the main menu 2.3.2 WiFi With built in WiFi, you can view the video from a wireless camera (ONVIF or customized camera) or connect to a Wireless network. 2.3.
2.3.6 TVI camera test TVI camera tester support 720p 25,30,50,60fps/1080p 25,30fps, when TVI signal input,HD TVI camera image display, zoom,view photos,video record and playback,Coaxial PTZ control and call up the camera OSD menu. 2.3.7 AHD camera test(* Optional ) AHD camera tester, support 720p 25,30fps/ 1080p 25,30fps, when AHD signal input, AHD camera image display, zoom ,view photos ,video record and playback ,Coaxial PTZ control and call camera OSD menu. 2.3.
can get fall below the threshold for the video display to show a color image. For NTSC format, the Chroma standard level is 40 IRE For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will get washed out. If the Chroma level is too high, there will be spots on the image. If the coaxial cable is too long, it will reduce the chroma level 2.3.10 PTZ controller Display the input video images.
2.3.15 PTZ data analysis Search the Control protocol code from Multifunction keyboard or DVR by RS485 interface, test the PTZ control command data whether received anomaly and RS485 data transmission. Screen displays 16 hexadecimal codes such as PELCO-P:A0 00(Add) xx xxxxxx AF xx PELCO-D:FF 01(Add)xx xxxxxxxx 2.3.16 Digital Image zoom on the monitor Set image zoom up to 4X to get a closer look at all the image detail. Supports analog and many IP cameras 2.3.
IP network cameras. 2.3.24 Network bandwidth testing The network bandwidth test needs two IP testers to test bandwidth: one as a transmitter, the other as a receiver. 2.3.25 IP address scan The IP address scan can quickly search for connected IP cameras or another network device IP address. 2.3.26 PING Test PING is the most conventional network debugging tool; it is used for testing if the connected IP camera or other network equipment is working normally and the IP address is correct 2.3.
2.3.31 Optical Power Meter(* Optional ) The IP camera tester adopts the most advanced handheld instrument specific integrated chip , achieve ultra-low power operation, with the 3.5 TFT-LCD High-definition screen display ,five wavelength calibration points 1625nm,1550nm ,1490nm , 1310nm , 1300nm , 850nm.Linear or nonlinear optical power display, it can measure the optical power value, and also be used for Relative measurement of optical fiber link loss.
2.4 Packing list 1). Tester 2). Adaptor DC12V 1A 3). Network cable tester 4). Polymer lithium ion battery (3.7V DC 3000mAh ) 5). BNC cable 6). RS485 cable 7). SC,ST connector(Only for optical power meter) 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models) 9). Camera powering cable 10). Audio cable 11). TDR alligator clamp (only for TDR models) 12). Safety cord 13). Tool bag 14).
2.
1 Press more than 2 seconds, turn on or off the device ,short press to turn on or off the menu display 2 Set key 3 Menu key 4 Near focus: Focus the image nearby 5 Far focus: Focus the image faraway 6 TELE: zoom in the image 7 WIDE: zoom out the image 8 Open/set ,Confirm the setting of parameters, open or enlarge the aperture 9 Return/Close : Return or cancel while setting parameters of the menu, close or decrease the aperture 10 11 Upward, set function or add parameter.
22 The RS485 data transmission indicator: it lights red while the data is being transmitted 23 The charge indicator: it lights red while the battery is being charged.
24 Video signal input(BNC interface) 25 Video signal output(BNC interface)/cable tracer interface ( Optional) 26 TDR cable test interface / TVI input (BNC interface) 27 DC12V1A power output , for provisional DC power supply 28 Not support RS232 communication 29 LED flashlight (lamp) 30 RS485 Interface: RS485communication for the PTZ 31 LAN test interface 32 PSE power sourcing equipment.
34 Reset key 35 UTP cable port: UTP cable tester port/ Cable tracer port 36 DC12V1.5A charging interface 37 Micro SD card removable (comes with 4GB, supports up to 32GB) 3. Operation 3.1 Installing the Battery The tester has built-in lithium ion polymer rechargeable battery. The battery cable inside battery cabin should be disconnected for safety during transportation! Usually it doesn’t need to disconnect the cable at the normal use Pressing the key continuously can power on or off the tester.
otherwise damage the tester. Warnings: Not allow insert multi-meter pen in the current terminal to measure voltage 3.2 Instrument connection 3.2.1 IP camera connection Power an IP camera with an independent power supply, then connect the IP camera to the IP tester's LAN port, if the link indicator of the tester's LAN port is green and the data indicator flickers, it means the IP camera and the IP tester are communicating.
3.2.2 Analog camera connection (1) The camera or dome video output is connected to CCTV IP Tester VIDEO IN,the image display on the tester . (2) IP Tester “VIDEO OUT” interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor (3) Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface (Note positive and negative connection of the cable) 3.2.
(1) Connect the SDI camera's video output to the IP tester’s “SDI IN” interface, the image will display on the tester. The tester only come with SDI input interface. There is no SDI output interface. (2) Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface (Note positive and negative connection of the cable). 3.
Select Icons to enter, if quit, Please click Click SD card, install or remove SD card Press function Icons seconds, tip: whether move this icon to APPS file, if some function not be often 20
used, can move these function icons to APPS.
3.3.
“Record” , “Playback” , “PTZ” , “Set” , Click to quit, or press back to menu. Click the screen twice quickly, can be full zoom in on the touch screen. 3.3.1.1 PTZ controller parameter setting Select and click icon “PTZ” ,to enter PTZ setting: A. Protocol Use the up and down arrow keys to move the yellow cursor to the “protocol ”, set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco-D,Samsung,Yaan,LiLin,CSR600,Panasonic,Sony-EVI etc. B.
F. Tilt speed: Set the tilt speed of PTZ camera (0~63) G. Set preset position (Set PS) Click and select “Set PS”, set and save preset position number (1~128), H. Call the preset position (Go ps) Click and select “Set PS”, set and save preset position number (1~128), click “sure” to save, Call some special preset number, can call the dome camera menu Check and set the protocols, address, interface and baud, all must be consistent with the dome camera, dome camera, then the IPC tester can test .
3.3.1.2 Video and storage setting Click icon "set" ,to enter and set analog video image brightness , contrast, color saturation, as well as the file storage way after snapshot and recording, support auto-storage and manual storage. When select manual storage, user can name and store the files. 3.3.1.3 4 x zoom image display and Video out When image input, press to enter “zoom” ,press it again to quit.
For analog video input, as the resolution is 720*480, it is normal that the zoom in image is not clear. But for network digital video input, as it supports resolution up to 1280*960, the zoom in image is still very clear. This is very helpful for IP camera installation. 3.3.1.4 Snapshot Click the icon "Snapshot ", when the video in, to take a picture and save the current video frame in the SD card as JPEG file.
3.3.1.6 Photo Click the icon "photo" to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return.
Click to close and return to PTZ controller. 3.3.1.7 Record playback Click the "Playback" icon to view your recorded videos. Tap on the video file image you want to watch.
Video files also can play in the main menu “Video Player". 3.3.1.8 Video level meter(* Optional) Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC level and COLOR BURST Chroma level. When an analog signal is fed into the meter, the tester displays the measurements on the bottom left corner of the screen.
NTSC PAL Video signal level 140±15IRE Chroma level( COLOR BURST) 40±5IRE SYNC signal level 40±5IRE Video signal level 1000±200mV Chroma level( COLOR BURST) 300±35mV SYNC signal level 300±35mV Video signal PEAK to PEAK level: For NTSC format, the video signal level is 140±15IRE For PAL format, the video signal level is 1000±200mV If the level is too low, it will cause the image to lose quality and limit the distance it will travel over cable. If the level is too high, it will distort the image.
trigger the displays color producing circuit. Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image. For NTSC format, the Chroma standard level is 40 IRE For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter. If the Chroma level is too high, there will be distortions on the image.
to full display on the screen and output, click to return main menu. Application A. When maintaining the dome camera, the tester sends out the color bar by its BNC output to the monitor at the monitoring center. If the monitor receive the color bar, it means the video transmit channel works normally. Meanwhile on the basis of the received color bar, the monitoring center can judge if transmission has loss or interference. B.
Click icon to enter, the tester Auto-Scan different network segments ONVIF cameras, and list the camera name and address on the screen left. Some cameras not need user name and password to login, Please select “Non- verification” to login the camera. If you select ONVIF SD or HD mode, the meter automatically scans different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List.
pass word. Some network cameras, does not require a user name and password authentication, check "non-verification" and then login the camera. Click “device list” of the tester’s screen left, will shows the camera information and setting. Such as “Device information”, “Time setting”, “Maintenance” “Network setting”, “User management”, “Live video”, “Image setting” etc. Some functions must camera's setting open to operate. Live Video: Click "Live Video" to view the live video feed from the IP camera.
ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ rotation direction is displayed on top left corner of the image. Video Streaming: Click “Video Set” to enter, set the IP camera decoding resolution, click “OK “to save.
Image setting: Click "Imaging Set" to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. Profiles :Click"profiles", can view video streaming current configuration files, as well as switch between Major stream and minor stream .
Preview pictures:Quickly preview and zoom in or out pictures, automatically and manual refresh Network setting: Click “Network Set” to change the IP address settings. Note: Some cameras are not fully ONVIF compliant and cannot support changing their IP address, so there is no change after saving.
Zoom in image: press the key to enter the zoom mode. Press it again to exit zoom mode. When the image is enlarged tap left, right, up or down on the image to move the whole image on the screen When the image is enlarged, if not operate on touch screen, it can operate by the keyboard ,press the key to zoon in , press the key to zoom out ,press upward and downward key to move image .
camera’s video coverage and decide the IP camera’s install site. Image can only be enlarged on SD mode (The icon “ONVIF” is SD mode.) On the interface of “Live Video”, click “Video Menu”, appears toolbar: Snapshot, Record, Photo, Playback, PTZ, Set, etc.
Set: Click icon “Set”, Photo and record function can select, if Auto-name, Photos and recording files Auto-storage, if manual, user define files name. Playback: Click the "Playback" icon to view saved videos. Double click the video you want to play.
Video files can play in the Video player of the main menu 3.3.4 IP camera test Click icons to enter IP camera test The “IPC Test” app is used for IP cameras that are fully integrated by name with the IP tester . If the IP camera's video stream is MPEG4, use the IPC Test (SD) mode. If your IP camera's video stream is H.264, use IPC HD (High Definition) Display high-definition images, support snapshot, video record and playback.
IPC test interface Local IP:This is the tester's IP address. Click "Edit" to enter "IP setting" and change the tester 's IP address settings IP camera type :Click IP camera type, list Honeywell , Honeywell , Kodak,Tiandy, Aipu-waton,VVS, ACTi,WoshiDA IP camera etc.
If IP address setting has error or IP camera is not connected.. The tester prompts “Network Error” Click to quit from image display and return to IP camera test interface. Under the IPC Test , on the IP camera image display, there is “Video Menu” icon, click “Video Menu”, appears toolbar: Snapshot, Record, Photo, Playback, PTZ, Set, etc.
3.3.5 TVI camera test HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter When tester receives HD TVI camera image, it will display the image’s resolution on the top bar. Double-taps on the screen to make the image displayed full screen.
1.1 Click the icon “PTZ” on the right toolbar to do the corresponding setting. “Port”: select coaxial control Enter PTZ address to perform parameters setting Operation instructions please refer to “3.3.1 PTZ (1) PTZ control parameters setting” The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test .After setting the parameter, the tester can control the PTZ and lens.
To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ. PTZ control by press key button Press arrow keys to control the PTZ direction of rotation Press the key to switch on or turn off the aperture. Press the key , adjust the focus manually Press the key ,manually adjust the zoom 1.
Operation instructions ,please refer to “3.3.
(3)Snapshot, record, photo viewer and video playback, please refer to “3.3.1 Video monitor test” (4)Save setting Click icon “Set” on the right toolbar to enter storage setting. Support auto-storage and manual storage. When select manual storage, user can name and store the files.
3.3.6 IP address scan Connect the cable to the LAN port, click icon to enter, set initial IP and destination IP address,to the tester’s IP address network segment can be the same or different to the scanned network device’s network segment, then click the key “Start” to scan, quickly to search the IP address, also can input the IP address in the Port Number Scan to scan to port number ,check the tested device’s supporting port number and how many ports can support the device’s network communication.. 3.
Application: PING testing is the most conventional network debugging tools. It is used for testing if the connected IP camera or other network equipment’s Ethernet port is working normally and the IP address is correct. It’s normal that the first data packet will be lost when test start. 3.3.
Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV TESTERPRO and cable tester. And then the connection status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed. The number of the cable tester is 255 If need several different number other types cable testers, should pay the additional cost. 3.3.9 Port finder Connect a network cable to the meter’s “LAN” port; click the icon to open the Port Flashing app.
Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection. 3.3.10 Data monitor Please click icon to enter Click “Setting” to choose the baud rate of RS485; it must be the same as the DVR or the Control keyboard .
shown on the upper right, like Pelco D, if not, like P:--When the tester receives the code, Press the key to clear screen. Though the RS485 port, display the PTZ control code of the multifunctional keyboard or the DVR. Controller can check the status of the RS485 transmission through the code on the display. (The RS485 communication rate must be the same.) Application: Check the RS485 communication states of the video optical transmitter whether normal.
⑶OPERATING INSTRUCTION DC Voltage Measuring a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/Ω” jack. b .Select U, enter the DC voltage measurement. c. the tester default Auto range status ,by click “DC auto range” , press the key can select manual range and restore auto range . Manual range: 0.000V 6.600V range 00.00V 66.00V range 000.0V 660.0V range 000.0mV 660.0mV rang AC Voltage Measuring a.
range; c.Manual range: 0.000mA 6.6mA range 00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A range(use 10A socket) d. Select the range to enter current measurement Note: When only the figure “OL” is displayed, it indicates over range situation and the higher range has to be selected. When the value scale to be measured is unknown beforehand, set the range selector at the highest position.
select range ,Press “NEAR” to restore “Auto range” Manual range: (Connect the red lead to black leads, will display the measure range) 000.0Ω 660Ω range 0.000 KΩ 6.600KΩ range 00.00 KΩ 66.00KΩ range 000.0 KΩ 660.0KΩ range 0.000 MΩ 6.600MΩ range 00.00 MΩ 66.00MΩ rang Continuity Testing a. Connect the black test lead to the “COM” jack and the red test lead to the “V/ Ω” jack. b. to select , enter the continuity test, Connect test leads across two point of the circuit under testing. c.
Capacitance Measuring a. Connect the black test lead to the“ COM ” jack and the red test lead to the “V/Ω ” jack. b. Select “ ” to enter, enter the capacitance measurement. c. The tester default auto range status, and manual range by press upward and downward key, Auto rang by press the key “NEAR” Manual range:0.000nF 6.600nF range 00.00nF 66.00nF range 000.0nF 660.0nF range 0.000uF 6.600μF range 00.00uF 66.00μF range 000.0uF 660.0μF range 0.000mF 6.600mF range 00.
Data hold Click “Hold data” to enter, the data be hold, the value is green. Press it again to quit. Relative value measurement Click “Relative “to enter ,the tester Auto-save the data, the displayed new measurement and relative value is red color.
when change the fuse, Please opens the battery cover to change. Note: 10A socket without fuse protection, if over the current range Wrong using the 10A socket to measure the voltage, will damage the meter. 3.3.12 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV. The IP Tester’s recorded files can play directly via the Media player.
3.3.13 Audio player Click the icon to enter , the audio player only supports MP3 format Audio files. 3.3.14 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon to enter While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off.
will stay on. Click the Time Setting button to set a timer that will shut off the lamp. 3.3.15 PoE/PSE Voltage test Click icon icon to enter the PoE voltage in line measurement app. Connect a network cable from a PoE switch to the IP tester’s PSE IN port. Connect an IP camera or other PoE using node to IP tester’s LAN port, the PoE voltage and the cable’s pin connection status show on the screen.
3.3.16 Calculator Click icon to enter 3.3.17 Browser Click icon to enter Type in the camera’s IP address and press “Go” to access the IP camera’s interface. NOTE: You will not be able to view live video in the web browser. For viewing video, use the IP tester live camera view apps.
The IP camera and IP tester must be on the same network segment for the browser to interface with the camera. If they are not in the same segment, click the button or press “RETRUN” to exit. Open the “Settings” app from the main menu to change the IP tester’s network settings to match those of the IP camera. 3.3.18 IP camera viewer In addition to the ONVIF app or the IPC Test app, you can use one of the mobile apps in the IPC Viewer folder to view IP camera video.
Click desktop icon several seconds, to uninstall this application Click icon “update “ in the IPC viewer interface, to update mobile apps 64
3.3.19 DC12Vpower output Click icon to enter DC 12V power output interface. To use the DC 12V power output function, click on the icon and change the switch “ON” or “OFF”. If to click without prior to change the switch “ON” to “OFF”, the 12VDC power output will till stay on, and the icon”12V ON” appear on the top bar. Change the switch “ON” to “OFF” to shut off the 12VDC power output.
1 .Don’t input any power into the “DC12/1A OUTPUT” port of the IP camera tester to avoid destroy. 2. Don’t output this DC12V/1A power to the DC12V/IN port of the IP camera tester to avoid destroy 3. The IPC tester power output is close to 1A, if the IP camera’s power is over 2V, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester. 4.
open the Network Tester app. Note: Network test results only used as a reference, For more accurate test , please use a professional Ethernet tester . When test , need a tester or a computer installed Network Test Software as the Server, the other tester sends packet test. The two testers must be in the same network segment. 1. Start the server: Click “Start Server” button to use the tester as a Server. It will display its IP address at the top of the screen.
2. Start send packet test::Using the other IP tester and type in the Server's IP address at the top right corner of the screen. This app is used to send packets for network speed testing. Click the “Start” button to send the packets and start testing. Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, with tester mutual –testing.
Tester as Client, tester’s IP address is:192.168.0.230. The Server and the Client are at the same network segment, but with different IP address. Input Server’s IP address 192.168.0.89 in the tester and click “Start” to test network bandwidth.
When tester as Server, shows results: DHCP server: Click on the DHCP icon to open the DHCP server app. Select the “Start” check box at the top and make any desired changes to the network settings. Click “Save” to start assigning dynamic IP addresses for IP cameras and other networked devices. Click the “Refresh” button to check your Client list. “Refresh” to check received IP address.
Notepad: Click on the Notepad icon to open the Notepad app. Click the “Save” key to save the contents pls click to view the notepad , all saving contents display. Click each record bar to show the details.
Link monitor : Click the icon to open the Link Monitor app. This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts. Click “Add” and enter the desired IP address. To test different network segments, click the “Settings” icon on the main menu and go to IP Settings and make the desired changes. Once the desired IP addresses are added to the Link Monitor list, click “Start”. If the IP address status shows a check mark the IP address is occupied.
Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera’s RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera’s user name. IPC Password: Enter the IP camera’s password. Once you have entered all the necessary information, select Enter at the bottom left to view the RTSP stream.
Note: in the event the ip tester does not auto detect the rtsp stream, refer to the specific camera manufacturer for the specific rtsp stream url. you may find this on line with a search of the camera model number and the word rtsp. Trace route: Trace route is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Please use professional Ethernet tester.
Click “start” to trace the goal address 3.3.21 APPS Tools Click the icon to open the Tool Folder. You can move desktop icons into the Tools Folder by pressing on the icon for a few seconds until the screen below appears You can also move an icon back to the desktop by pressing on the icon for a few seconds until it asks you if you want to move the icon back to the Desktop.
3.3.22 System Set Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian or Polish, etc. Date/Time: Set the Date/time IP setting: Manually set the IP address, Subnet Mask, Default Gateway, DNS address or select “Dynamic allocation” to use DHCP. To test multiple network segments, click “Advanced” and then click “Add” to enter another IP address for the IP tester.
After setting an advanced IP address (refer to above photos), the tester can test two network segments (192.168.0.0) and (192.168.1.0). WLAN:Turn WiFi off or on by pressing the “Open the Wi-Fi” button. Once Wi-Fi is turned on, it will scan for wireless networks in your area. Select the desired wireless network SSID and enter your password to connect networks in your area. Brightness::Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level.
Start the FTP server and then input the tester’s FTP address in the PC’s address bar. (ftp: as:ftp://192.168.0.233:2121) This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader Version information: This displays the version information for each application. Screen rotation: Click on “Screen Rotation” to flip the IP tester’s display 180 degrees.
3.3.23 Update Click to enter If there are applications for updating, the applications will be displayed on the interface. Click the relevant applications to update to the latest version. 3.
Click the switch “OFF” to“ON” to turn on DC12V 1A power output function.. The smaller end of the supplied converter cable connects to the tester’s DC12V/1A OUTPUT and the other end connects to the camera’s power input. Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some camera installation sites, if there is no power outlet for the adapter to power the camera, the tester can offer temporary power for it.
4. Specifications 4.1 General Specifications Model IP Camera tester【*】models Optional Display 3.
playback 12V/1Apower Output DC12V/1A power for camera output 1 channel audio signal input, test whether sound normal, supports record Audio test and save audio Support RS485 control, Baud 600-115200bps, Compatible with more PTZ control than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc Video signal Output one channel PAL/NTSC color bar video signal for testing generator monitor or video cable.
TDR cable test Cable open circuit (breakpoint) and short circuit measurement(BNC cable, Coaxial cable, Cat5/6, telephone cable) * (Optional) POWER External power DC 5V(1.5A ) supply Battery Built-in 3.7V Lithium polymer battery ,.
6.600V 1mV 66.00V 10mV 660.0V 100mV AC voltage Range 660.0mV (Manual range) Accuracy ±(1.5%+6) 6.600V Resolution 0.1mV 1mV 66.00V ±(0.8%+6) 660.0V 10mV 100mV DC current Range Accuracy 6.600mA 66.00mA 1uA ±(0.5%+3) 660.0mA 10.00A Resolution 10uA 100uA ±(1%+5) 10mA AC current Range Accuracy 6.600mA 66.00mA 1uA ±(0.5%+3) 660.0mA 10.
Range Accuracy 660.0Ω Resolution 0.1Ω ±(0.8%+5) 6.600KΩ 1Ω 66.00KΩ 10Ω ±(0.8%+2) 660.0KΩ 100Ω 6.600MΩ 1KΩ 66MΩ 10KΩ ±(1.2%+5) Continuity Range 660.0Ω Resolution 0.1Ω Function The measurement value less 30Ω±3Ω,the tester will sound Diode Range Resolution Function Schottky diode:0.15~0.25V 2.0V 1mV rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Capacitance Range 6.600nF Accuracy ±(0.5%+20) 66.00nF 100pF ±(3.5%+8) 1nF 66.00μF 660.0μF 1pF 10pF 660.0nF 6.
6.600mF 1μF 66.00mF 10μF 4.3 Optical power meter specifications -70~+10dBm Measure Range(dBm) Wavelength(nm) 850nm,1300nm,1310nm,1490nm,1550nm,1625nm InGaAs Detector <±3%dB( -10dBm,22℃) <±5%dB(full range ,22℃) Uncertainly Linear:0.1% ; Nonlinear:0.01dBm Display Resolution Operating Temperature(℃) -10~+50 Storage Temperature (℃) -20~+70 FC/PC Connector type 4.
Connector FC/PC exchangeable Working Temperature -10℃~+50℃ Operating Temperature -20℃~+70℃ The data above is only for reference and any change of them will not be informed in advance. For more detailed technical inquiries, please feel free to call the Technical Department of our company.
BY 88