WIRING TO HOST CONTROLLER:
MOUNTING:
Zodiac mounts on a single-gang electrical box.
1.
Remove screw from bottom of unit.
2.
Remove back mounting plate by pulling gently from inside the cable feed-through hole.
3.
Insert the Wiegand cable from the wall through the hole in the back plate, then mount the back plate to the electrical
box with the supplied screws.
4.
Remove the plug-in connector from the unit and connect Wiegand cable as per wiring instructions on Page 1. Plug the
connector back into the unit.
Important: Confirm wiring as 12VDC applied to incorrect pin can damage the unit.
5.
Attach the main unit to the back plate by tilting the bottom of the unit toward you, then sliding the top of the unit over
the back plate.
6.
Secure the main unit to the back plate with the screw removed in step 1.
LED and BEEPER CONTROL:
The LED line is used to control the LED on the right side of the unit. This LED is normally RED and will turn GREEN when
the line is pulled LOW.
The BEEPER line is used to activate the unit’s internal beeper. The beeper will sound if the line is pulled LOW.
INSTALLATION INSTRUCTIONS:
MODEL CA-ZODRCS ZODIAC FINGERPRINT ACCESS READER