PREFACE Canon Dial 35 is a product of Canon's proud quality control system, Asa’ result of wide market research, traditionally high technical skills and rigid inspection before delivery, Canon's Dial 35 is enjoying full confidence of its buyers as a high quality easy to handle completely automatic dime-size (18 x 24mm} camera. Because of the above-mentioned manufacturing stern, Dial 35 is almost breakdown-prof.
Section CONTENTS HOW TO USE THIS SERVICE MANUAL GENERAL Section REPAIR MANUAL Table of Contents Exploded View and Parts List index of Parts Numbers Section REPAIR GUIDE Table of Contents Disassembling Methods Adjusting Methods Trouble, Cause and Remedy Inspection Standards Section SERVICE TOOLS LIST Section Section PRICE LIST OF CANON SPARE PARTS SERVICE MANUAL REPORT
HOW TO USE THIS SERVICE MANUAL Canon Service Manual consists of the following six sections: General, Repair Manual, Repair Guide, Service Tools List, Price List of Spare Parts and Service Manual Reports, which will be issued if the outward appearance, function or design of the product is changed. These six sections are divided by index heels for easy identification, GENERAL The General section consists of information useful to the repairman.
11. The part number of the part which can be supplied as a separate service part though it is one of the components of a bonding part, such as the Window or the Light Shield, is shown in the round brackets. The bonding part in this case includes those parts above said when ordered ss the form of the bonding part, 12. When you want to identity a part from its pair number, see the Index of Parts Numbers at the end of the repair manual REPAIR GUIDE 1.
1 REF, NO. 145401 EXPLODED VIEW of CANON DIAL 35 3-r38m a 97-8298 13-7213 | 13-arr oly 1 of Lie eet & xi-170228, ot Misty +4 Sit) 13-7220 Tt List) 13-7222 I wt Last 19-3678 def Lisa 13-val mr 13-1219 taf Link) “13-7239 “ nf 5, Kinswoman ®. Xi 4-i70227. 13-7376 ier insist 13-7242 << > 7210 é 13-721 or XI O-AQIST, X40-170257 3-7207 SCALE 1-1.5 CANON CAMERA CO. INC.
REF. NO. 145401 PARTS LIST COVER SHUTTER RING 13-7210 Leather 13-7267 Shutter Ring 13-7211 Leather 13.7241 Multiple Lens 13-7212 Leather 13-7242 Aperture Disk 13.7213 Leather 13.7243 Click Dowel 13.7328 Shutter Bunion Guard XI-170287 Setscrew 13.7329 Counter Window 18-0144 Fr amt & Back Cover (Unit) MANUAL KNOB Parts which is mentioned by italic in the illustrate. 19-9508 Manual Knob (B. PF.) son, for example, 19-8431 (cf. List)etc. is included X10-140157 Setscrew in the Cover Unit 18-0144.
REF. NO. 14540] VIEWFINDER ¥00.0449 10-0084 10-0085 10-0086 10-0087 10-0088 10-0089 13.7208 13.7338 19-9492 17-7022 X14-200458 13.7375 13-7380 13-7384 13-7397 97.5056 97-8067 X11-200301 X14-200408 X96-141049 Viewfinder (Unit) Lens Half Mirror Lens Lens Mirror Mask Eyepiece Frame Finder Cover Finder Base Plate Spring Screw Light Shield Light Shield Battery Cover Collar Coil Spring Battery Plate Screw Screw Screw EXPOSURE METER 18-0121 X11.
REF. NO. 1. 45401 TAKING LENS 13-7231 Focusing Aver 13.7246 Key 18-0119 Helicon (Unit) 18-0152 Taking Lens (Unit) 97-4054 Screw X10-140158 Setscrew BASE PLATE 13.7308 Counter Stopper 19-9513 Base Plate (8.7) 19-9514 Stop Lever (B.P) 97-4059 Screw 97-6128 Spring X11-140187 Screw X11-170158 Screw X14-200457 Screw X32-501523 Washer X32.501812 Washer xN ¥86-172113 Screw GOVERNOR 13-7400 Step Collar 13-7301 Collar 13-7309 Rewind Lever. 13.7393 Stopper 13-3604 Governor {BLP} 19.9515 Governor Base (B.
4 REF. NO. 1 45401 EXPLODED VIEW of CANON DIAL 35 w X32-40HTR \ in 7200 f/x 203208, po PR S0RU3, 97-7033 19-9500 & ER 13-729) LY X BE-S0B2, av 3-731 13+ Xian, 3T 2 a 13-7377 xazs08es XO, 8 97-5062 2 a7.009a 97-5083 . 3250624, 2 Awesome, 7 97-5051 4® ~ 13-7369 7-005 13-7358 “9 X32-40HQ1 19-3497 19-9506 i ” 13-7203 13-7209 . 11200407 £3 @ X-40187 . Fl
REF. NO, 1. 45401 SHUTTER BASE 13.7311 13-7373 13-3497 19-9500 Xi-170228 X11-200407 X14-200357 X32-501821 SHUTTER 13-7209 13.7245 13-7292 13.7293 13.7365 97-5050 97.5054 87.7029 X11-140187 X11-170188 X71-1131 SPROCKET 13.7290 13.7261 13.7354 15-9498 19-9499 §7.7033 X32.401172 X32.502113 X91.
5 REF. NO. 1. 45401 EXPLODED VIEW of CANON DIAL 35 § 97-4085 #70089 w@ X32-502131 @ 97-4058 19-9494 Sd X10-170207 97-0089 97-0087 = & e-s058 | @ x32-502031 97-4085 {2.2 AR-onss ! ! Frozen 8 | CED 97-0088 ~ ; © X32-502181 x32-509213 X32-502131 13-7368 13-7270 13-7266 » 8 13-7267 [ mousse i. T @ 13-7386 + %32-502i1 13-7201 > XUE-08037S i 3 x-7002 7 wo 12-7278 & cir-0m T @ x98-030068 & Xp 38-7279 3 © cir-ore SCALE 1-1.5 CANON CAMERA CO. INC.
REF. NC. | 45401 BODY CASE 13-7201 13-7268 13-7346 (phase 2-505212. PARTS LIST Body Worm Gear Bearing Light Shield Washer xN TAKE-UP SPOOL 13-7356 13.7368 19-9436 87-1073 X32.502111 REWIND GEAR 13.7278 19-9507 97-1075 X71-7002 X98.030068 X98-080375 IDLE GEAR 97-0088 97-0088 47-4085 97-4056 X32-502131 DRIVE SHAFT 13.7266 13.7287 13.7270 13.7275 19-9494 97-0087 97-1074 97-5048 97.
PART NO. Y00-0449 10-0084 10-0085 10-0086 10-0087 10-0088 10-0088 10-0080 10-0091 13.4162 13-7201 18-7207 13-7208 13-7209 13-7210 13-7211 13-7212 13-7213 13-7219 13.7220 13-7221 13-7222 13.7224 13-7225 13.7227 13-7228 13-7231 13.7239 13-7241 18-7242 13.7243 13.7248 13-7246 13.7259 13-7265 13-7266 13.7267 13-7270 13-7275 13.7279 13.7290 13-7291 13-7292 13-7293 13-7300 13-7301 PAGE 2 mR RON RN WoW EE BR UCD GRR BRS ee (Dm INDEX OF PART NUMBER PART NO, PAGE PART NO.
CANON REPAIR MANUAL SHUTTER for CANON DIALS (REFERENCE NO. 1.
EXPLODED VIEW REF. NO. 1-48401 of CANON DIALS g Yin-0057 ¥I3-0020 off ¥13-0022_ pe” LAE, 13-005 Yin-0044 & Y13-0064 to/ Y13-0011 Y13-0056 2 ® 13-0021 “ae 13-0016 13-0053 113-0018 ! i-00ss a | | ™ ~ | 13-0023 NE 3000 g Y13-0015 13-0063 Yin-0062 NO SCALE CANON CAMERA CO, INC.
REF. NO.
REF. NO. 1-45401 4 EXPLODED VIEW of CANON DIALS Yin-0071 goon AF © Y13-0073 OO © © Coy NO SCALE CANON CAMERA CO. INC.
TABLE OF CONTENTS Disassembling Method Front & Back Cover Finder & Meter Base Plate .. Shutter Base Shutter ,..
FRONT & BACK COVER DISASSEMBLING (1) Shutter Ring (13-7207) Te x 3 {X10-170257) Multiple Lens (13-7241) Aperture Disk (13-7242) Click Disk {13-7243) Shutter Button Guard | (13.7323) => Light Shield (13-7376) @ . Screw x 2 (X14-170184) Manual Knob (19-9508) or Screw x 3 @ (X10-140157) Focusing Knob (13-7239) ORDER REMARKS 1. Removal of shutter Pull out screw ring X16~1706257 pull out shutter ring Multiple lens 13-7207 13.
FRONT & BACK COVER DISASSEMBLING (2} Screw x 2 @ (X93-200080) < Butt F fc Ben | R Button 8 (13-7224) ¢ red Coil Spring (97-5280) CIT Fig. 1 Fig. 2 ORDER 4. Removal of Remove 2 screws R button X93-200080 Remove button frame 13.7225 Screw x 2 {X10-200304} Remove spring Remove R button 97-5280 13-7224 5, Removal of grip Remove 2 screws X10-200304 Remove winding grip 18-0120 nm 2) (3) Winding Grip (18-0120) REMARKS Screws are of double sets. Grip is removed by turning to the left.
FRONT & BACK COVER DISASSEMBLING {3) Screw x 3 (X14-200253) Screw x 2 (X11-200208) Light Shield & : (13-7358) © a Fig. 2 SS Fig. 1 7] Fig. 3 ORDER REMARKS 6. Peeling off Peel off the leather {large, large leather leather medium, small) from the sides of 13-7211 the body case. Medium leather 13-7210 Small leather 13.7212 7. Removal of case Remove 3 screws (Refer to Figs. 2 and 3} 14.
5. Screw x 2 =F (X96 172076) Fc earwax om (13-7313) Manual Boss Q Fd ED Washer Fig. 1 Removal of manual boss Removal of clamp plate Removal of the screws Removal of Cd§ Removal of finder Ol FINDER & METER DISASSEMBLING @ Screw (X11-200301) é Screw _ (X14-200408) Screw . (X11-200127) Fig. 3 Fig. 2 ORDER NOTES Turn the manual shaft inside the Be careful of the click manual boss (13-7227) and remove spring and ball inside the the manual boss. boss can be removed without The manual manual shaft.
1. 2. Screw BASE PLATE DISASSEMBLING Screw x2 {X14-200608) {X14-200457) ORDER NOTES Removal of screw Pull out the 3 screws When removing the 2 X14-200608 x 2 screws {X14-200608 x 2) X14-200457 be careful not to drop the collar, Removal of base Remove in the direction of the Also be careful of the plate art Ow. meter needle.
SHUTTER BASE DISASSEMBLING Screw x 2 {X14~200357) EE Cam Screw x 2 — {X11-200407) Coil Spring / ~— Zone Focus Index (97-5054) | « (13-9493) Ny Shutter = Light Shield 2 vid (13-7378) = 5 Light Shield 7 butter Base (13-7378) ji Light Shield (13-7388) ORDER NOTES 1. Removal of zone Screw Zone focus index Be careful not to bend the focus index. 97-4057 19-9493 removed index. {Refer to Fig. 2) 2.
SHUTTER DISASSEMBLING EE Gam (13-7209) Washer Dust Cover (13-7293) Shutter (X71-1131) Coil Spring or (97-5050) ee » Hook Screw x 4 (12-7311) X11-1 | { 702283 Release Ring ¥ {13-7212) Fig. 1 Release Ring Fig. 2 ORDER NOTES 1.
SHUTTER ADJUSTMENT 1. Method of Refer to method of disassembling: Pages 4 ~ 11, disassembling Note 1 : Dismantle the EE cam, coil spring, ASA, click stop screw and re-use. 2, Inspection of 1, Move diaphragm lever and observe movement of separate parts diaphragm. 2. Inspect the shutter charge as well as the release and rotating condition of the shutter dial, 3. Method of 1. Installing the EE cam. assembling Shutter Diaphragm lever {D cme Position gauge Screw 1.
4. Methods of adjustment 1. = Adjust the charge lever, Adjust the overlap to more than 0.6mm in order to prevent the tip of the charge lever from becoming disconnected from the shutter charge lever during cocking. When making adjustment, bend the charge lever. Charge lever... Charge lever 2. Leeway of charge. There should be a charge leeway 0.6mm at the tip of the lever after the shutter has been charged. When there io Ben no leeway “> When there is a considerable leeway 3. Adjusting the timing. 3.
3.4 In this condition, the foot of the index lever should be within specifications as shown in the diagram below. In repairing, bend the foot after once removing the index lever. the plate thickness of lever from the rim of the notch.
METER ADJUSTMENT 1. Method of 1. See methods of disassembling: Pages 4 7. disassembling Note 1: When replacing the meter, always replace the meter, resistor and CdS as a single set, 2: In removing the meter, remove the screw and avoid touching the indicator of clamp needle. 2. Fitting the meter 1. Fitting. Z. Wiring and soldering. Resistor 3. Meter adjustment 1. Adjusting the manual diaphragm.
Meter needle 2: On this occasion, use the gauge to measure the diameter of the diaphragm. 3: fit is not within the limits, loosen the screw of the EE cam, and adjust by moving the EE cam and changing the diameter of the dial diaphragm. During this process, the needle remains clamped to the sixth groove. Note: Diametrical value of diaphragm 6.95 4.96 2.49 1.36 1.04 D 6,42 4.48 2.20 1.13 0.82 ne 5.89 4, 06 1.92 0.89 © 0.
7: 8: Release shutter. Measure the diameter of the lens aperture at FB. (Use limit gauge.) Next, use light intensity of 2880 cd/m?, with shutter at 1/250, On this occasion, check the F8 diameter of the diaphragm. If the measurement is outside the limit, make adjustments by putting a brush of India ink on the Cds or by wiping off the ink according to the condition.
BASE PLATE ADJUSTMENT 1. Methods of 1. See methods of disassembling: Pages 1 ~ 7. disassembling Z. Base plate unit 1. Installing the stop claw. Note 1: The up and down play at the tip of the claw of the stop claw should be under moving the stop claw, lightly move {before the spring is attached) the claw by its own weight only. 2. Screw fittings and spring attachments.
Note 1: Apply liquid molybdenum grease to the contact surface of the shutter release lever pin and release lever. 2: Put diamond on the screw of the base plate. 8. Check EE cam. The EE cam should move smoothly without touching the base plate. Note 1: The distance between the EE cam and the base plate should Adjusting the stop 1. Adjusting the position of the stop lever. lever 1,1 Rotate the sprocket, and adjust the position of the stop lever as shown in the diagram below during the shutter charge.
Installation and 1. Installation and inspection, inspection of 1.1 Place governor in governor drum, and by rotating governor it lightly with the fingertip check whether it rotates smoothly and without any catch. 1.2 Attach to governor base, release the stop lever and rotate the spool. Confirm the unobstructed move« men of the worm gear, helical gear and governor, Adjust rotating speed 1, Attach spring, inspect and adjust when fully charged.
1, Methods of disassembling 2. Methods of installing FILM COUNTER ADJUSTMENT See methods of disassembling: Pages Retainer Ee Counter dial Oneal Foot [= ae = ‘Base plate 1. Attach a spring to the foot of the film counter dial, and set after making one winding revolution to the left.
TROUBLE, CAUSE & REMEDY WINDING 1. Two~frame advance 1. Incas speed of revolving governor is fast. Clean inner surface of the governor drum, observing change after applying a small quantity of lacuna oil on the governor axis. {When grip is fully charged the revolution is 3-5 seconds.) If the speed is still too fast, reduce the speed scraping arm of governor, as shown in the diagram. Scrape arm with razor 2. In case of imperfect movement of the stop lever.
2. Continuous advance i. 3. should be within the scope shown in the diagram below. Note 1: Check the reverse side and two places. Foot of index lever Ce The limit of leeway plate thickness of lever, It is common for two-frame advance to occur when timing is fast. As a method of later adjustment, adjust by bending the foot of the index lever as shown in the diagram below. Precision of the calculator clamp.
3. 4. Winder failing to function after shutter has been pressed When there is a large amount of empty advances 1. 1. 2; The spring should be properly installed. 3: If the spring is misshaped, make replacement, Inadequate amount of sprocket lobe. ATT 1mm The amount of sprocket lobe should be within 1.21.6 mim. The set position of the sprocket base plate should be set towards the direction of the sprockets protrusion. Note 1: Readjust timing of index lever. ‘When stop lever spring is too strong.
5. 3. Unusual sound during 1. the winding 2. 3. Although the grip 1. has been coiled, winding is not possible 2. When the friction gear axis is not working, when the axis shifting spring is weak, this phenomenon is the result. In repairing, remove axis once and strengthen the spring. Note 1: The friction of the revolution should be below 40g. (Measure with tension gauge {Cortex Co. 3 The friction gear is weak. Replace the friction spring. Governor and washer out of shape, Replace governor.
REWINDING 1. When rewinding the 1. grip is charged FILM COUNTER 1. Film counter failing 1. te advance. In case the cartridge is defective, The defect occurs when the process of extracting the film is unnecessarily heavy, caused by misshaped or worn put cartridge. Heavy spool friction.
disconnected. 2. Weak friction gear. Use » dummy case to advance the film. See that the film counter accurately indicates the number of films advanced, ~Replace spring 2. When the film counter 1. Inadequate movement of R lever. fails to return to S Open the back cover, and when the shutter is released, if the counter returns from 0 to S, the cause of the defect is the R lever. Raise by bending the R lever, 5 © position Foot of counter 3, Failing to return even 1. Clutch gear does not return.
1. 3, 4. When the 0 position of 1. the film counter does not fit SHUTTER 1. When shutter cannot be charged 2. Heavy shutter pressure Spring cuts into groove A and is unable to move If the return is faulty, although the film counter not in contact with any other part, the cause is the spring's adherence. Replace spring. Note i: Do not stretch spring and use. Defective position of counter stopper. Readjust counter stopper position with appropriate pulling tool.
3. Failure of shutter 1. te return 4. When shatter button 1. cannot be pressed on account of occasional catches. METER 1, Meter indicator hitch 1. Tension gauge { (Cortex Co.j Shutter Release lever Measure the tip of the release lever with the tension gauge (Cortex Co, }. The scale should be below 50g. Replace shutter if it is over 50g. Hitch in the movement of the EE cam. ni Manual boss pen EE cam Loosen the manual boss without the button being returned.
2. Faulty meter 1. movement 2. 3. 3. The manual indicator 1. fails to move 2. 4. Over or under. exposure The space {A and B) between the needle and the base plate window brim or clamp plate brim should be within 0. When it is outside the limit, it is apt to touch the brim. Adjust by bending the indicator. In case it is in contact with the frame glass. Meter needle T= Space about 0, 3+ 1. Omm n Adjust in the same way by bending the indicator. Note 1: For both 1 and 2, check the manually operated lens at 2.
INSPECTION STANDARDS External appearance Condition of assembly 2,1 Disparity at joint section of back cover and front plate Play of hinged section Shutter ring rotating torque Pull of rangefinder lever Pull of film sensitivity ring Pull of manual knob Finder section Visibility Visual field Parallax Image break Coincidence precision of zone focus index Spring motor 4.1 4.2 4.3 Generating torque Slip torque Number of winding up Winding up the film 5.
10. 5.2 Speed of wind-up 5.3 Spacing of film Shutter 6.1 Second timing 6.2 Barton stroke 6.3 Pushing pressure 6.4 Safety system 6.5 Position of shutter click Flash Socket Insulation resistance Contact efficiency wb wend WN ee 7.4 Circuit resistance 7.5 " Time lag Rewind 8.1 Pushing pressure of button Film counter dial 9.1 Automatic advance 2.2 Advance 9.3 Return 9.4 Coincidence precision of indicator and scale unloading Film loading; unloading; and advance 10.1 Loading and unloading 10.
11. Back cover 11.1 Opening and closing 11.2 Bite 11.3 Parallel degree of opening between back and front covers 12, Exposure setting device 12.1 Lens aperture value 13. Manual diaphragm 14. Photographic lens 14.1 Focus When the back cover is closed the stop claw should work, and it should not open when the knob for open ing and closing has not been operated. Under 0.5mm. Opening 0. 5mm, parallel degree under 0.2mm. B.S.
CONTENTS VIEWFINDER EXPOSURE METER TAKING LENS GOVERNOR .virevrranivunanrvenine ve FILM COUNTER Racketeering . SHUTTER . WINDING GEAR ..
REF, NO. 1-48421 PARTS LIST CASING & WINDING GRIP 13.7207 Shutter Ring 13-7211 Leather 13-7212 Leather 13-7224 Rewind Button 13-7225 Rewind Button Frame 13.
2 REF. NO. 1.45421 EXPLODED VIEW of CANON DIAL 35-2 13-7385, 3 er] Sn TEE KILO 4 (10-0090 {40-0091} X18-200257 x2 19-0327 SCALE 1-1.
REF. NO. 1.45421 CASING 10-0090 10-0091 13.7219 13.7220 13.7221 13.7222 13-7385 13-7386 13.7391 14-0802 14-0806 14-0807 14-0811 14-0813 14-0853 14-0863 19-0327 19-0330 X16-170228 X1B-170227 X18.
3 REF, NO. 1.45421 EXPLODED VIEW of CANON DIAL 35-2 10-0187 tJ . 57-7002 00 . x-5220ga], X61-60a8,, #16-200306 Xi-200207 — 18-0358 X24200358 X64-4902 7 ) HIB -200608 STL 19-0443 137397 14-0829 19-0842 << “. X32-50063) 97-4057 qr soi @ = 14-0821 X EA-I00T!_ pr raceway-0n 97-5085 SCALE 1-1.5 © CANON CAMERA CO.. INC.
REF. NO. 1-45421 PARTS LIST VIEWFINDER & EXPOSURE METER YO-1148 10-0084 10-0086 lo-0087 10-0088 10-0187 10-0203 13-7208 13.
4 REF. NO. 1-45421 EXPLODED VIEW of CANON DIAL 35-2 13 Aldan) 7388 [eee @57-40se XI 2-HOIE31 4 er 99H zit-r7oiss Kiowas 13-7318 : No ° 13-7393 # Q 0 97-6128 13-7319 . , “ig a-r00 ¥18-200408 oS 32-502! CE a < 13-7308 @ X32-501523 OQ © X11-140157 ™ 97-6296 16-200608 18-7300 ea. | 97-6614 Xi-200408 | 19-0332 & p Q) oes \ 18-9504 @ 19-9674 ) SCALE 1-1.
REF. NO. 1-45421 PARTS LIST TAKING LENS, GOVERNOR & FILM COUNTER 13.7231 Focusing Lever 13-7246 Key 13.7300 Collar x 3 13.7301 Collar 13-7308 Counter Stopper 13.7309 Rewind Lever 13.7318 Release Lever 13.7319 Push Rod 13-7378 light Shield 13-7387 Light Shield x 2 13.7388 Light Shield 13-7389 Light Shield 13.7393 Stopper 13-7396 Light Shield 13-7399 Light Shield 14-0823 Shutter Button 14.0825 .
5 REF. NO. 1-45421 EXPLODED VIEW of CANON DIAL 35-2 X32-40031 X91-20% Goa § xor-203209,, 19-9500 | 97-7033 SER 13-7281 &z 16-0852 mem 8 L 13-7311 | 7-557 ee XI-70187 X32-501624 sf” ! ® 67-0084 — i 97-5053 To xazs0i624, 5 yd 97-501 5 o 13-7363 . / 97-00% Duos 7 SZ oan A GF ox-qong 19-0328 Co : X32-40101 15-8506 | 13-7336 . ad 13-7293 97-5316 i 14-0847 T [4 X32-50152 X-143002 ~ XI-70I88, , hd 13-7245 87-7023 SCALE t-1.
REF. NO. 1.48421 PARTS LIST FILM COUNTER & SHUTTER 13-7245 13.7291 13.7292 13-7293 13-7311 13-7336 13-7354 13.7369 13-7373 13-7398 14-0847 14-0852 14-0854 14-0861 19-0329 19-0336 19-9498 19-9499 19-9500 19-9506 97-0094 97-0096 97-5050 97-5051 97-5052 97-5053 97-5316 97-5571 97.
EXPLODED VIEW of CANON DIAL 35-2 & i 19-9494 Te XI0~7A307 97-0087 97-4056 47-0089 97-5048 1 32-5002 13-7270 dL { Fm, 13-7266 a = 13-7267 XB2-50M2NED Xt rel) 87-4058 G7~0089 ¥ 97-4055 * | | 97-0089 67-4055 97-0088 19-0333 X86-141039 9 HSS oy” Ps 13-7265 ao S & 13-7389 X34-1005415 hy XS-080375, 13-7345, 7 ES) 14-0815 > X98-040375, ! © zed-506211 4] 14-0816 i 57-1074 / SCALE 1-1.5 & X9+iT3108 @ CANON CAMERA OD REF. NO. 1.
REF, NO. 1-45421 PARTS LIST WINDING GEAR, TAKE-UP SPOOL & BODY CASE 13-7265 13.7266 13-7267 13.7270 13-7275 13-7346 13-7356 13-7368 13-7389 13-7400-03 14-0815 14-0816 19-0333 19-9494 19-9496 97-0087 97-0088 97-0089 97-1073 97-1074 97-4055 97-4056 97-5048 97-5049 97-8971 X10-170307 X32-502111 X32z-504121 X32-505211 X32-506211 X32-509213 X34 100541 X91 .
REF. NO. 1-45421 INDEX OF PRAST NUMBER PRAST NO. PAGE PRAST NO. PAGE PRAST NO. PAGE PRAST NO. PAGE Y00-1148 3 13-7369 5 18-0361 1 97.5316 5 13-7373 5 97-5571 5 10.
CONTENTS Disassembling Method Front & Back Cover Front Cover Shutter Base Plate and Exposure Meter Adjusting Method Shutter-1 Exposure Meter Base Plate Helicon .. Shutter-2 Trouble, Cause & Remedy Winding is disabled Lo... i i Cetacean Continuous film advance Continuous release Rewinding stops midway Grip is charged during rewinding Film counter does not feed or stops midway «.
1. 4. FRONT & BACK COVER DISASSEMBLING 13-7225 13-7223 re go X91-202454x2 X98-100395xN >) Work Removal of aperture disk Removal of focusing knob Removal of manual knob Removal of shutter button ring Removal of rewind button Removal of front & back cover unit Feo 18-0361 I .
19-0327 i X19-200306 § Work Removal of name plate Removal of flash terminal Removal of front cover FRONT COVER DISASSEMBLING X18-2 2 00257. 7-897 Nee 19-9509 (13-7239) No > 13-7376) { 19-0335) 3 {X106-170256x3) | (14-0826) (13-7207) (14-0822) (19-9508) Remove aperture disk (19-0338), {focusing knob (13.7239), manual knob {19-9508} and shutter button ring (14-0822) as in the procedure for front & back cover disassembling. Remove name plate (97-8972) and two screws {X18-200257).
| X16-170258x4 Work Removal of lens unit Removal of shutter speed adjusting ring Removal of shutter base unit SHUTTER DISASSEMBLING Cds (13-7239) “ ( (X18-170227x2) (13-7376) (X10-170256x3) {13-7207} > X10-140158x2 Specifications Remove aperture disk (19-0335) and focusing knob {13-7239) as in the procedure for front & back cover disassembling. Loosen two screws (X10-140158) and remove the lens unit.
SHUTTER DISASSEMBLING Y13-0054x2 Y13-0072x4 cL Y13-0073 Shutter Base Unit Frame Work Specifications Removal of shutter Remove three screws {Y13-0002), and take off the shutter blades base unit from the frame. Then extract two shutter blades {Y13-0054). Removal of aperture Remove two screws (Y13-0071) and stationary bearing ring blades then extract four diaphragm blades (Y13-0072).
BASE PLATE AND EXPOSURE METER DISASSEMBLING YEW-1148 X16-200306 "o x16-200207 18-0358 . X71-5218x2 ¥ 13-7397 Base Plate Unit X71-5219 X18-200608 AN * 14-0821 wv AN X18-200408 13-7227 Work Specifications Removal of Remove manual boss (13-7227) and clamp (14-0821). viewfinder unit Take off screw (X71-5219) and spacer (13-7397) from the base plate side, and screw (X24-200358) and viewfinder eyepiece side screw (X16-200406) from the cassette chamber (main body) side. Then detach viewfinder unit (Y00-1148).
SHUTTER ADJUSTMENT 1 Work Inspection 1. 2. Mounting 1. 2, ER Specifications Check if the aperture smoothly works by operation of the aperture lever. Check if the shutter is charged and released smoothly, and if the shutter speed ring rotates smoothly. Fixing EE cam: EE Cam Washer Aperture Lever Set the EE cam on the aperture lever as illustrated above, and tighten it moderately with the screw. Screw n.
3.2 The release ring should be positioned with the hook lever being on the upper side, as illustrated below, Hook Lever Fig. 3 Release Ring 3.3 Attach the intermediate ring between the release ring and the shutter base, 4. Fixing shutter 4.1 Charge the shutter 4.2 The shutter should be positioned so that the shutter release lever is under the raised portion on the left side, facing the release ring, of the ring. Release Ring Shutter Release Lever Fig. 4 Tighten the screw. 4.
Adjustment 1. Adjustment of charge allowance CHECK: 1. Charge the shutter by rotating the sprocket, 2. Charge the shutter again and measure how much charge lever 1 moves, ~~ Charge Lever 1 Fig. § A: Position after £= Charge Allowance | charging £ — B: Start position A B Charge Lever 2 STANDARD: Charge lever 1 should move 0.4 ~ 0, fmm. ADJUSTMENT: Bend the charge lever bend with a pair of pliers. Plate Spring Charge Lever : Increase Decrease Fig. 6 2. Adjustment of plate spring position CHECK: 1.
ADJUSTMENT: Bend the plate spring. Leaf Spring Charge Lever Index Cam Overlap should be greater than d. Fig. 8 3. Adjustment of timing CHECK: I. Let charge lever 1 lightly touch charge lever 2. 2. Under the above condition, turn the sprocket reversely until the projection of the index cam touches the bend of the charge lever. Charge Lever 1 Index Lever Charge Lever 2 [Andes Gam Fig. 9 3.
Attachment STANDARD: Tolerance is hall of the claw's thickness io the both sides from the full line positions illustrated right above in Fig. 10. ADJUSTMENT: Detach the index lever from the shutter base, and bend the claw of the lever with a pair of pliers. 5. Attaching shutter base to body case: Body Case Shutter Base Unit 5.1 Move the aperture lever full counterclockwise and insert the bell crank pin into the hole in the body case. 5.2 Insert the pinion pin into the hole. 5.3 Tighten screws.
EXPOSURE METER ADJUSTMENT Work Specifications Inspection Gently blow the needle and check its movement. n.k. 1.0 When replacing the meter, the CdS element should also be exchanged. 2. When handling the meter, be careful not to bend the needle and clamp needle. Attachment 1. Fixing exposure meter: Tighten the meter with two screws at positions A and B, Meter Fig.
Meter circuit diagram I Battery 3 Exposure Meter =, denotes connection Pe Variable Resistor by soldering. Fig. 14 Cas 4. Fixing viewfinder unit: Be careful not to bend the meter needle, Adjustment 1. Adjustment of clamp needle position Check if the needle is at the center between the clamp plate plate and the base plate. If it is off the center, correct it by bending the needle. Base Plate © Meter ©) Clamp Plate Fig. 15 EE Cam 2. Adjustment of aperture CHECK: 1.
STANDARD: aperture Dmm Dl ppl 7.39 | 6.42 | 5.45 8 3.34 | 2.20 | 1.665 Fig, 17 ADJUSTMENT: Loosen the EE cam set screw, and move the cam as illustrated. Decrease Increase Fig. 18 nib, 1. The aperture lever, to which the EF cam is fixed, easily deforms itself. Attach a screwdriver under the lever when con ducting the above adjustment. 2, Check if the EE cam is in contact with the has plate and if the cam moves smoothly. 3.
ADJUSTMENT: Bend the needle. nb. 1. Do not make the clearance between the finder Mask and needle too large. 2. The needle should not touch the zone focus index. When the adjustment described in It eras I~ 3 above has been finished, set the spring of the clamp plate and attach the manual knob. 4. Adjustment of manual operation STANDARD: 1. Clearance between the manual knob and needle should be 1a 1. Sam. 2. The needle should move smoothly in manual. 3.
5.2 Adjustment of high and low warning indication STANDARD: EV ASA 5.8 Position of Needle G 16 1730 Should enter the "low" warning mark. 14 400 1/30 Should enter the "high" warning mark. Fig. 22 ADJUSTMENT: Use the variable resistor and cover the CdS element with black ink. After this adjustment, conduct re check as in Item 5.1 above. 5.
BASE PLATE ADJUSTMENT Work Specifications Disassembling ni. b, When removing the governor drum, dissolve the bonding agent which fixes the drum, then evenly extract the drum from the arrow position shown in Fig. 24. ~ Governor Base { 1 vet ser WaT Governor Drum Fig, 25 I the drum is lifted as shown by an arrow in Fig. 25, it must be careful because the shaft attached to the drum may tilt or the edge of the drum may have bur, possibly resulting in faulty winding. Assembly of base plate 1.
Attachment Adjustment 1. Charge the shutter and drop the index lever into the V-shape groove. 2. Attach the worm gear to the body case, and the push rod and shutter release lever to the base plate. 3. Attach the base plate to the body case. Fig. 27 Base Plate Gear Shutter 2) Release Lever Body Case 1. Adjustment of take-up gear rotation CHECK: After tightening the base plate with screws, gently rotate the take-up spoil in the take-up direction, and check if the take-up spool rotates smoothly. ADJUSTMENT: 1.
. Spe Fig. 29 Adjusting Washers —* f— © Upper End (Helical Gear Lower {Spool Side} End Side} Bearing of Take-Up Bearing of Take-Up Shaft Shaft n.b. After tightening the bearings, confirm that the take-up shaft has play by depressing the top end of the shaft, 4. Slight catching when the take-up spool rotates, some what may be corrected by weakening the corrugated washer for spoil torque. nb. I the washer is weakened too much, the rewind button cannot be reset quickly when rewind shifts to take-up.
ADJUSTMENT: Remove the push rod, and increase or decrease the number of washers between the shutter button and push rod. 3. Position adjustment of first stop claw CHECK: Turn the sprocket, and check the position of the stop claw in relation to the gauge on the way the shutter charges. First Stop Claw Fig. film counter is provided, move the counter stopper so that it does not overlap the film counter arn, before conducting the check. STANDARD: The stop claw should be on the standard surface of the gauge.
3. Check if the counter arm returns to the now of the counter stopper when the rewind lever is depressed, Depress the rewind lever Counter Stopper First Stop Claw ™ Film Counter Arm Film counter returns 4, Check the space between the tip of the governor claw and the first stop claw when you detach your finger from the rewind lever being in the state of the item 3 above. 5. Check the S position of the counter. STANDARD: 1.
5. Position adjustment of second stop claw CHECK: 1. Check the operating condition of the stop claw by directly pressing the second stop claw at first, then pressing the shutter button, 2. Check the engaging condition of the second stop claw and release ring. Release Ring Second Stop Claw Fig. 36 STANDARD: The stop claw should touch the center of the width of the release ring. ADJUSTMENT: Bend the raised portion of the release ring. 6.
HELICON ADJUSTMENT Work Specifications Inspection It should rotate smoothly with a certain weight. Attachment 1. Attachment of helicopter unit The focusing ring should rotate lightly. Z. Attachment of lens Fit the raised portion of the focusing ring to the fork of the key. Screw the lens unit to an appropriate position and temporarily fix it with two screws, Adjustment 1. Adjustment of key end play Bend the key with a pair of pliers so that the end play between the key and focusing ring may Imm.
Index positioning for Im focus Bend the portion of the focusing lever shown in Fig. 39 so that the index should point the portrait mark when the focusing lever is set at the portion shown in Fig, 38. rT For adjustment, bend this portion. —. Fig. 39. Confirmation of index position for The index should be above the long distance mark when the focusing lever is touched with the stopper, Confirmation of index position for 0.
Work Inspection Attachment SHUTTER ADJUSTMENT 2 Specifications Inspection of inside of shutter unit 1.1 Operating condition of blade opening lever and blade operating lever. Installed position of flash contact and timing of switch-in, Operating condition of governor Operating condition of release lever Movement of aperture lever Attachment of EE cam Be careful not to bend the aperture lever. Manually set the aperture at F22. Align the positions of release ring and intermediate ring, Attachment of shutter 4.
Attachment of speed setting ring. Ii the surface of the nut is higher than or equal to the helicopter attaching surface, attach the speed setting ring over again.
1. 2. Trouble Winding is disabled. Continuous film advance. TROUBLE CAUSE & REMEDY Cause & Remedy Oil on shutter blades Governor gear operates improperly. {In most cases, gear teeth are deformed.) Teeth of helical gear are deformed. Worm gear and helical gear are improperly engaged. First stop claw position is improperly adjusted. Brake arm of governor {19-9504} is deformed. Drum shaft is inclined or calking is loose, Take-up spool torque is excessive. Index lever is improperly adjusted.
Continuous release {Successive winding during shutter release) Rewinding stops midway. 2.4 4.1 Shape of second stop claw tip is improper. Second stop claw does not operate smoothly. Index lever is improperly adjusted. {Timing is too fast), Film counter {19-0332) is faulty itself, Shape of governor claw is improper. Governor rotates too fast, Charge has no allowance. Pressure plate has insufficient pressure. Projection of sprocket is insufficient. Position of charge lever is improper.
5. Grips charged during rewinding. 6. Film counter does not feed or sips midway. 7. Film counter does not return Rewind gear train does not rotate smoothly and lightly, Rewind Fork Rewind fork has insufficient end play. Sprocket does not rotate lightly. {Sprocket touches the body case or the shaft pressing spring is too strong. ) Gear train does not rotate lightly, spool torque is excessive. Grip is defective, Engagement of pinion gear (97-0096) and counter gear is insufficient.
Shutter cannot 8.1 be charged. 8.2 8.3 8.4 Shutter button G.1 does not return {or return is 2 unstable). 9 Meter needle 10.1 does not swing. 10.2 10,3 Meter needle 11.1 stick. 11.2 11.3 11.4 Counter stopper is improperly adjusted, Charge has no allowance. Timing of index lever is improper. Projection of sprocket is insufficient. Pressure plate is insufficient. Release ring (13-7292) is bent. Screw for setting gear the shutter release lever is louse. CdS lead wire soldering is faulty.
12. In manual the needle does not move. 12.1 12.2 12. 3 Space between clamp needle and manual knob is too wide. Clamp needle touches front cover. EE cam {14-0847} does not return properly. 33 Refer to "Adjustment of manual operation’, page 17.
CANON SERVICE TOOLS LIST CANON DIAL 35-2 {REF, NO, 1-45421) TESTING EQUIPMENT Use Names of Testing Equipment Focus 1 200mm T-type Collator Focus Mirror for 35mm Field of View 1 Universal Parallax Collator : 2 Frosted Glass Exposure Meter 1 Inspection Device for Canon Meter SPECIAL SCREWDRIVERS T0199-18-0357-1T Tightening Winding Grip Tightening Flash Terminal T0199-19-9509-1