Installation Guide

INSTALLATION INSTRUCTION FOR FIXTURE
7473-4H, 7474-4H, 7476-4H,6678-4H,6686-4H
WARNING! SHUT OFF THE POWER AT FUSE OR CIUCUIT BREAKER.
MOUNTING THE FIXTURE
1. Shut off the power supply at the fuse box or circuit
breaker box. Remove the old fixture from ceiling.
Including the universal mounting plate.
2. Carefully unpack your new fixture and lay out all the
parts on a clear area. Take care not to lose any small
parts necessary for installation.
3. Thread the nipple (J) into the coupling (L) tightly;
4. Assemble the tube (E) together using nipple (D) well,
then thread the bottom end of tube (E) onto the nipple
(F) and thread the top end of tube (B) into the swivel
(C) tightly with thumb screw;
5. Put the candle cover (I) over the socket (K), then put
the fabric shade (H) over the candle cover (I) and
Install the light bulb in accordance with fixtures
specifications. DO NOT EXCEED THE MAXMUM
WATTAGE RATING!
6. Thread 2 mounting screws through the mounting screw
holes from the back of the universal mounting plate.
7. Attach universal mounting plate to the Outlet box using
2 Box Screws. The side of the universal mounting plate
marked GDN must face out.
8. Follow the wiring instructions carefully (See Fig.2).
9. Attach the fixture main body onto the out let box by
protruding 2 mounting screws through the mounting
screw holes on the fixture canopy (A), then tighten it
with 2 ball nuts (B).
Wiring (See fig.2)
1. Connect the electrical wires as follows. Connect the
black wire from the fixture to the black (HOT) house
wire. Connect the white wire from the fixture to the
white (Neutral) house wire. Make all the wire nut was
secured. You may wrap the connections with
electrical tape. If your outlet box has a ground wire
(Green or Bare Copper) connect fixtures ground
wire to it. Other wise attach the bare copper fixture
wire to the green ground screw on the cross bar.
2. Tuck the wire connections neatly into the ceiling
junction box.
Fig.2
NIPPLE(D)
SWIVEL(C)
TUBE(E)
FIXTURE BODY(G)
NIPPLE(F)
OUTLET BOX
WIRE CONNECTORS
FIXTURE CANOPY(A)
Fig.1