access standalone with built-in card reader&access standalone CV-550SPKv3& CM-550SKv3 USER MANUAL -1-
Content 1 Overview.................................................................................................................................................................... - 4 1.1 Introduction.........................................................................................................................................................- 4 1.2 Function features...................................................................................................................................
4.1.22 Set key backlit mode.............................................................................................................................- 21 4.1.23 Adjust brightness of key backlit...........................................................................................................- 21 4.1.24 Set buzzer mode....................................................................................................................................- 21 4.1.25 Adjust key volume.....................
1 Overview 1.1 Introduction This series of products are using the new 32-bit microcontroller ARM core design with powerful functions. They are very stable and reliable. It’s a new generation of multi-function access controller, include Reader mode, Single-door mode, Double-doors mode, Interlock mode, Demo mode etc. All of them could be widely used in office buildings, homes, schools, condominium, apartments, flats, single houses, banks, prisons and other places. 1.
1.3 Functional unit 1.4 Technical parameters Working Voltage: AC/DC10-28V Standby current: ≤35mA(Input DC12V) Operating current: ≤100mA(Input DC12V) Working temperature: -40~60℃ Working humidity: 0~95% Lock signal relay contact current: ≤1A Alarm (or doorbell) signal MOS tube output current: ≤1A Distance of reading EM card:≤5cm Distance of reading HID card:≤5cm Distance of reading IC card:≤5cm 1.
2 Installation, wiring and debugging 2.1 Installation With the special anti-demolition screw-driver remove the anti-demolition screw at the bottom of the device. Take off the bottom case, and contrast the opening position of the bottom case and use the impact drilling to open the corresponding hole on the wall. It includes an outlet hole with a diameter greater than 8mm and four plastic screw holes with a diameter of 6mm.
Red +12V(AC1) Positive DC power(or another port of AC power supply) Black GND Ground Green D0 Wiegand signal, D0 input or output(or RS232-TTL signal output: Tx) White D1 Wiegand signal, D1 input or output(or RS232-TTL signal input : Rx) D_IN2(LED_R) Door contact input of zone 2 (or external control input of red LED) Yellow & Black OPEN2 Exit button input of zone 2 White & Black NO2 Normal open port of Relay 2 Green & Black COM2 Common port of Relay 2 NC2 Normal close port of Relay 2
-8-
-9-
- 10 -
- 11 -
- 12 -
2.3 Debugging After power on, conduct the test according to Getting Started till you can open door by reading card, input PIN or exit button. 3 Getting Started Writing Conventions: Keypad operation only can be used between “0123456789*#” these12 buttons “…” means continue similar operation as indicated from previous operations. “,”is not an actual operation, it’s just punctuation.
The first unlock zone Green The second unlock zone Blue Alarm Red quick flash Alarm Sound 3.1 Enter management menu operation mode * (Hold on for more than 2 seconds), (Input admin password) # Note: Admin password is a 6 digits number, 888888 is the factory default admin password. The user should change the admin password when use the device for the first time, otherwise user cannot continue other operations.
3.7 Exit Management menu operation mode In Management menu operation mode, press * more than once until the indicator light turn to red and always bright means exit Management menu operation mode. 3.8 User open door When the indicator light is red and always bright, read card, or (input user PIN) #, or press exit button. Note: When the door opens, there is a long "beep" sound and the indicator light turns to green when the door is unlocked. 4.Basic Functions 4.
4.1.2 Set or delete Super-open-password 00,( 8 digits ) #, set Super-open-password 00,0000 #, delete Super-open-password Note: these functions are available under the First and second zone management menu. First and second zone Super-open-password must not be the same, otherwise only open the door of first zone. Super-open-password has the highest permission to open the door and it can use to open the door anytime. 4.1.3 Set admin card 01, 0#, read card, read card, …, Set 1-3 Set-cards.
The valid menus for Demo mode are: 03,09,32,34,51-53,55. 4.1.6 Limits types of reading card 04, 0#, cannot read any card. 04, 1#, can read EM card only. 04, 2#, can read HID card only. 04, 3#, can read IC card only. 04, 4#, can read EM+HID card. 04, 5#, can read EM+IC card. 04, 6#, can read HID+IC card. 04, 7#, can read EM+HID+IC card. Note: Whether you can read a card is determined by the specific model and the codes above. 4.1.
11, (ID) # 10# (10-digit format card number) #, (ID) # 10# (10-digit format card number) #, … Specified ID number and input 4-6 digits PIN to add user: 11, (ID) # (User PIN) #, (ID) # (User PIN) #, … Note: ID number are 1~5 digits between 1~20000, User PIN in zone 1 are any 4~6 digits, except 1234, User PIN in zone 2 are any 7 digits. 4.1.8.
4.1.12 Set lock working mode 32, 0#, default value, set lock to Delay mode. After an unlock operation, the lock is opened , then the lock will be closed automatically after a few moment of delay. Apply to normal open. 32, 1#, set lock to Switch mode. After an unlock operation, the lock will keep opening until another unlock operation again, the lock will keep locking, and so on. 32, 2#, set lock to Normal-open mode. Under this mode, the lock will keep opening, not controlled by other unlocking action.
Note: When the machine is illegally dismantled, it alarms and an alarm signal will be send out at the same time. The alarm can be canceled by inputting Admin Password, read admin card or user card. 4.1.18 Set alarm or doorbell output function 42, 0#, default value, alarm wire output alarm signal voltage. 42, 1#, alarm wire output doorbell signal voltage. Note: The Alarm wire is internally connected with the drain of the NMOS tube, and the output is active low, which can drive the current below 1A. 4.1.
4.1.22 Set key backlit mode 52, 0#, Normal-off mode for key backlit. 52, 1#, default value, Normal-on mode for key backlit. 52, (2-99) #, Automatic mode for key backlit, turn to micro light over 2-99s. 4.1.23 Adjust brightness of key backlit 53, 1, 1, ... , decrease brightness 53, 2, 2, ... , increase brightness Note: The brightness of the key backlight can be adjusted at 21 levels.
4.1.27 Set doorbell key mode 57. 0#, default value, the doorbell key is invalid. 57, 1#, the doorbell key is valid, but without volume. 57, 2#, the doorbell key is valid, with “ding dong” tone Note: When the doorbell key is valid, if a special doorbell decoder for our company be used with it, then the relay will connect after press the doorbell key, the relay will release after loosen the doorbell key.
4.1.28.4 Set wiegand output parity format for reading card 63, 0# wiegand output without parity check. 63, 1# default value, wiegand output with parity check (EO format) Note: EO format is standard wiegand format. Even check data add in front and Odd check data add in the end. 4.1.28.5 Set wiegand output format for pressing key 64, 0#, default value, single key output, 4 bits wiegand data(no check bit). 64, 1#, single key output, 6 bits wiegand data( with parity bit).
only admin card operation in the zone 1, admin card operation in the zone 2 is same. 4.2.1 Set-card operation The main function of Set-card is to replace the input Admin Password into the management menu operation. It is suitable for forgetting the Admin Password or frequently entering the management menu operation. Its operation is: Read Set-card, equivalent to operation: * ( Hold down for more than 2 seconds), (Admin password) #.
4.2.7 Authorization-card operation Read Authorization-card once, two short beeps, limit users. Read Authorization-card again, one long beep, release limit. Note: Authorization-card is also called header card, it authorizes users. By default, users can operate properly, you can use an Authorization-card when you need to restrict user access. 4.2.8 Normal-open-card operation Read Normal-open-card once, two short beeps, lock keep open, not controlled by other unlocking action.
Exit operation: Press exit button Note: In addition to the exit operation, make sure that the machine is not in a disable user state. You must first set up good way to open the door, open the door by multi-card also needs to set a good quantity of card. If card or PIN is valid, a long “beep”, the lock will be opened. During the opening time, LED turns green. After that, LED turns red and keep.
BEEP: Buzzer control wire, Buzzer keep sounds when low level. When LED_G & LED_R turns to low level together, the LED indicator light will turn to orange(LED indicator light mode is 0),Green(LED indicator light mode is 1) or red ( LED indicator light mode is 2) . 4.5.2 Operation characteristics in Single-door mode The default mode is Single-door mode, most applications work in this mode, in this mode, cannot operate the menu 60-64, also cannot enter the second operation zone. 4.5.
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu 03 04 09 40 41 42 50 Parameter or operation step 0# Reader mode 1# Single-door mode 2# Double-doors mode 3# Interlock mode 9# Demo mode 0# Cannot read card 1# Only read EM card 2# Only read HID card 3# Only read IC card 4# Read EM and HID card 5# Read EM and IC card 6# Read HID+IC card 7# Read EM, HID and IC card 0000# (1-99)# Set the alarm time to 1-99 minutes 0# Disable Anti-dismantle alar
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu 57 Parameter or operation step 0# The doorbell key is invalid. 1# The doorbell key is valid, but without volume. The doorbell key is valid, with “ding dong” 2# 60 61 62 63 Default value 0 tone. (0-255)# Set facility code 0# D0&D1 output wiegand format. 1# D0 output RS232-TTL-HEX format. 2# D0 output RS232-TTL-ASCII-8 format. 3# D0 output RS232-TTL-ASCII-10 format.
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu 03 04 09 10 11 Parameter or operation step 1# Delete 3 Add-cards. 2# Delete 3 Delete-cards. 3# Delete 3 Super-open-cards. 4# Delete 3 Anti-duress-cards. 5# Delete 3 Authorization-cards. 6# Delete 3 Normal-open-cards.
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu 30 31 32 33 34 Parameter or operation step Function 0# Open door way by card 1# Open door way by card and PIN 2# Open door way by card or PIN 1# Set one card to open door (1-10)# Set 2-10 cards together to open door 0# Set lock to Delay mode 1# Set lock to Switch mode 2# Set the lock to Normal-open mode 0# Disable users to use. 1# Enable users to use.
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu 55 56 57 Parameter or operation step Function 1# Enable the buzzer 1,1,…,# Decrease the keypad tone 2,2,…,# Increase the keypad tone 0# The # key can’t be used as doorbell key 1# The # key can be used as doorbell key 0# The doorbell key is invalid. 1# Doorbell button valid, no keypad sound 2# Doorbell button valid & sound Dingdong Default value 10 0 0 5.
Way to enter menu : * (Hold down for more than 2 seconds), 2(Admin password) # Menu 11 Parameter or operation step Function (ID)#, read card, (ID)#, read card, … Specify ID number and read card to add user. (ID)#8#(8-digit format card number)#, (ID)#8#(8-digit format card number)#, … (ID)#10#(10-digit format card number)#, (ID)#10#(10-digit format card number)#, … Specify ID number and input 8-digit card number to add user. Specify ID number and input 10-digit format card number to add user.
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu 09 32 34 51 52 53 55 Parameter or operation step Function 2# Double-doors mode 3# Interlock mode 9# Demo mode 0000# Default value Restore default settings, admin password and user information unchanged.
7 Common troubleshooting Fault phenomenon Possible causes Troubleshooting 1. The power line is too thin, or the use of no pure copper wire, resulting in voltage Indicator light is not working is too low. properly 2. Wrong connection or bad contact of power line. 3. Set the indicator light normal off 1. Hold the * key in front of the password longer than 2 seconds. Fail to enter management mode. 2. Input wrong admin password. 3. Forget admin password.
FCC Statement This device complies with part 15 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment.