Q Q - P O W E R 14 POWER AMPLIFIER USER MANUAL MADE IN GERMANY
Q - P O W E R 14 | POWER AMPLIFIER CONTENTS Welcome to the Q-POWER 14 User Manual 4 7. Protections 21 11. Specifications 27 Important Safety Instructions 5 7.1 Power Amp Protection Systems 21 12. Typical Performance Diagrams 30 Explanation of Symbols 7 7.1.1 Clip Limiter 21 12.1 Gain vs. frequency, 120 W output power 30 EC Declaration of Conformity 8 7.1.2 SOA Protection 21 12.2 Phase vs. frequency 30 1. Welcome to CAMCO 9 7.1.3 DC Protection 21 12.3 THD @ 1 kHz vs. input level 30 1.
Q - P O W E R 14 | POWER AMPLIFIER INFORMATION FOR USE Welcome to the Q-POWER 14 User Manual TDA282USERENB Please visit our website www.camcoaudio.com for the latest version of this user manual. Please note that the leading version of CAMCO manuals is always the English one. Revision B, 2015-02-02 © Copyright 2015 by CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen 4 / 42 www.camcoaudio.
Q - P O W E R 14 | POWER AMPLIFIER IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions 1. General The amplifier may only be used in accordance with the information provided in the user manual. Before and during the usage of the amplifier please ensure that all recommendations, especially the safety recommendations as detailed in the user manual, are adhered to. The Q-POWER 14 amplifier is designed for the amplification of pulsed audio signals.
Q - P O W E R 14 | POWER AMPLIFIER IMPORTANT SAFETY INSTRUCTIONS 11. Connections When you connect the amplifier to other equipment, turn off the power and unplug all of the equipment from the supply source. Failure to do so may cause an electric shock and serious personal injury. Read the user manual of the other equipment carefully and follow the instructions when making the connections. 15.
Q - P O W E R 14 | POWER AMPLIFIER EXPLANATION OF SYSMBOLS Explanation of Symbols CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION – HIGH VOLTAGE HAZARDS EXIST WITHIN THIS PRODUCT. REFER ALL SERVICING TO AUTHORIZED PERSONNEL. THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE.
Q - P O W E R 14 | POWER AMPLIFIER EC DECLARATION OF CONFIRMITY EC Declaration of Conformity EC Declaration of Conformity in accordance to EC Directives: Electromagnetic compatibility (Council Directive 2004/108/EC) Low-voltage electrical equipment (Council Directive 2006/95/EC) Manufacturer´s Name: CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Manufacturer´s Address: Fischpicke 5, D-57482 Wenden, Germany Declares that the product with the model name: CAMCO Power amplifi
Q - P O W E R 14 | 1 POWER AMPLIFIER WELCOME! 1. Welcome to CAMCO Thank you for choosing CAMCO products. You are now the proud owner of a very advanced CAMCO Amplifier. The technologies used in your amplifier are of the latest generation and designs delivering a far reaching set of results across all functions. 1.1 Unpacking Please unpack and inspect your new amplifier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately.
2 World’s first DSP controlled Power Supply in Professional Audio. The all new Q-POWER 14 with DSP controlled PFC power supply is the flagship of the series, offering up to 14 000 W of undistorted power in an very compact and lightweight package. The development of a DSP controlled, active PFC (Power Factor Correction) enables the Q-POWER 14 to use the mains power supply much more efficiently than conventional designs.
Q - P O W E R 14 | 2 POWER AMPLIFIER THE AMPLIFIER 2.1 The Q-POWER 14 Front Clip-LEDs I-Out-LEDs Signal-LEDs On-LEDs Volume controls channel A to D Removable air filter system Cooling air inlet vents On/Off switch Optional volume control security cover USER MANUAL 2.
3 Q - P O W E R 14 | POWER AMPLIFIER M A I N S S U P P LY 3. Mains 3.1 Mains Supply The Q-POWER 14’s power supply is a true wide-range SMPS with active power factor correction (PFC). This means that it can be operated anywhere in the world without the need of any manual voltage range setting. When mounting or connecting the amp always disconnect it from mains.
Q - P O W E R 14 | 3 POWER AMPLIFIER M A I N S S U P P LY 3.4 Mains Voltage Range To guarantee the best amplifier performance all over the world the power supply internally works with three mains voltage “grids” or “ranges”. These are: > 100 VAC (Japan) > 110-127 VAC (North and parts of South America) > 200-240 VAC (Europe and the “Rest of the World”) For each grid there is a set of highly optimised control parameters to get the maximum power performance achievable.
3 Q - P O W E R 14 | POWER AMPLIFIER M A I N S S U P P LY 3.
Q - P O W E R 14 | 3 POWER AMPLIFIER M A I N S S U P P LY 3.7 FuseProtect™ Limiter - Mains Circuit Breaker selection The integrated FuseProtect™ feature will at all times limit the mains current draw to the maximum current handling capabilities of the specific programmed MCB for each mains voltage range. When shipped, the Q-POWER 14 is programmed with default MCBs for each mains voltage range.
4 4. Mounting Use four screws and washers when mounting the amplifier to the front rack rails. For mobile and touring use, the amplifier should also be secured using the 19” mounting elements on the rear panel. 4.1 Mounting Dimensions Q-POWER 14 Q - P O W E R 14 | POWER AMPLIFIER INSTALLATION 4.2 Cooling The air is taken in from the front and streams out through the back. It is essential that while the amplifier is running the air is able to circulate around it freely.
Q - P O W E R 14 | 5 POWER AMPLIFIER CONNECTORS 5. Input and Output Connectors Input D Input C Input B Input A 5.1 Analogue Input Connectors - - - - XLR Euroblock Pin 1 ground Pin 2 hot (in phase, +) Pin 3 cold (out phase, –) Pin 1 hot (in phase, +) Pin 2 ground Pin 3 cold (out phase, –) 3 1 Make sure to always use high-quality symmetrical (balanced) shielded cable to ensure maximum audio quality.
5 Q - P O W E R 14 | POWER AMPLIFIER CONNECTORS 5.2 SPEAKON® Loudspeaker Output Connectors The four SPEAKON® connectors are connected to the channel A to D power amplifier outputs.
Q - P O W E R 14 | 6 POWER AMPLIFIER OPERATION 6. Operation 6.2 Controls 6.1 Indicators 6.2.1 Volume Control A volume control with 41 notched settings controls the audio signal. These settings have been selected to correspond to human hearing characteristics (logarithmically) and therefore guarantee an optimal range of settings for practical applications. Each channel can be set individually.
6 Q - P O W E R 14 | POWER AMPLIFIER OPERATION 6.3 CAMCO USB MCB Updater The CAMCO USB MCB Updater offers a set of different commonly used mains breakers, and allows to permanently store it inside the amplifier. The stored MCBs will be maintained even after power loss. The application also can display a graph showing in detail each MCBs tripping characteristic.
Q - P O W E R 14 | POWER AMPLIFIER PROTECTIONS 7. Protections 7.1 Power Amp Protection Systems 7.1.1 Clip Limiter If the maximum output level is higher than the amplifier can deliver, the Clip Limiter (if active) will reduce the output signal in order to limit distortion. The Clip Limiter works on each channel independently, but can only be activated for the channel pairs A/B or C/D respectively. The Clip LED sensitivity on the display is designed to be very responsive and accurate.
7 7.1.9 High Frequency Protection All outputs are permanently monitored for high-frequency high output signals. Continous output of 22 kHz sine-wave signals at full scale is permissible, but higher frequencies at very high output levels might trigger this protection. If detected, the corresponding amplifier module will be switched off for a few seconds and restarted again. 7.2 Mains and Power Supply Protections 7.2.
Q - P O W E R 14 | POWER AMPLIFIER F I LT E R C L E A N I N G 8. Filter Cleaning 8.1 Removing the Filter System and Cleaning The air intake on the front of your Q-POWER 14 amplifier is fitted with a removable filter system. If the filter becomes clogged, the unit will not cool as efficiently as it should and may lead to reduced output levels.
9 Q - P O W E R 14 | POWER AMPLIFIER VOLUME CONTROL SECURITY COVER 9. Volume Control Security Cover 9.1 Mounting the Volume Control Security Cover It is possible to install a solid protection over the volume controls to prevent intentional or unintentional changes of the amplifier volume settings. ! WARNING! Disconnect the amplifier from the mains before installing the cover.
Q - P O W E R 14 | 10 POWER AMPLIFIER TROUBLESHOOTING 10. Troubleshooting Here are some tips and tricks which might be useful when encountering weird amplifier behaviour during use. If none of the advices work please contact CAMCO for further support. > If this doesn’t help unplug the mains cable and wait for at least 2 minutes, then replug the mains cable and switch the amplifier on.
10 10.6 Signal and Clip LED of one or more channels are red intermittently This LED pattern indicates that the corresponding amplifier channel has gone to short-term protect mode. This can have multiple reasons: a) Short-circuit protection has been triggered (3 sec. protect duration). > Check the loudspeakers and cables for possible short-circuits. b) Overtemperature protection has been triggered (undefined protect duration, depending on temperature rise and fall).
Q - P O W E R 14 | 11 POWER AMPLIFIER SPECIFIC ATIONS 11.
11 Q - P O W E R 14 | POWER AMPLIFIER SPECIFIC ATIONS Q-POWER 14 Frequency response @ 4 Ω load with 120 W ouptut power THD+N over frequency @ 4 Ω load with 120 W output power Damping factor 8 Ω load, 1,7 kHz and below Input impedance Amplifier gain Maximum analogue differential input level Level attenuation Minimum loudspeaker load impedance Protection circuits Limiters Cooling LED indicators Input connectors Output connectors Update and Service connectors 10 Hz – 20 kHz: ± 0,1 dB 20 Hz – 8 kHz:
Q - P O W E R 14 | 11 POWER AMPLIFIER SPECIFIC ATIONS Q-POWER 14 AC mains supply AC mains connector AC mains startup range Mains voltage range for initial startup of power supply AC mains operating range Maximum amplifier output power performance will decrease when operating the amplifier at mains voltages smaller than -10 to -20 % of the rated voltage. à See also chapter 3.4 AC mains power consumption * Measured with pink noise @ 4 x 375 W / 2,7 Ω load. à See also chapter 3.
12 Q - P O W E R 14 | POWER AMPLIFIER TYPICAL PERFOMANCE DIAGRAMS 12. Typical Performance Diagrams 1 1 0,5 0 − 0,5 0,1 −1 dBr − 1,5 % −2 0,01 − 2,5 −3 − 3,5 −4 10 100 Hz 1k 12.1 Gain vs. frequency, 120 W output power (Measurement of a typical performance; 8 Ω /4Ω / 2,7 Ω 0,001 − 60 50k 10k − 50 − 40 − 30 dBu − 20 12.3 THD @ 1 kHz vs.
Q - P O W E R 14 | 12 POWER AMPLIFIER TYPICAL PERFORMANCE DIAGRAMS 0 0 − 10 − 20 − 20 − 40 − 30 − 40 − 60 dBr dBr − 80 − 50 − 60 − 70 − 100 − 80 − 120 − 140 − 90 10 100 1k Hz 10k − 100 20k 12.5 Channel separation vs. frequency @ 3 × 120 W / 4 Ω Only the measured channel has no signal, all other channels are loaded (Measurement of a typical performance; Ch 1 / Ch 2 / Ch 3 / Ch 4 10 100 1k Hz 10k 20k 12.7 Common mode rejection ratio vs.
12 Q - P O W E R 14 | POWER AMPLIFIER TYPICAL PERFORMANCE DIAGRAMS 1 600 500 Ω damping factor 400 0,1 300 200 100 0,01 10 100 Hz 12.9 Output impedance vs. frequency @ 1 A output current (Measurement of a typical performance) 32 / 42 www.camcoaudio.com 1k 10k 20k 0 10 100 Hz 1k 10k 20k 12.10 Damping factor vs.
Q - P O W E R 14 | 13 POWER AMPLIFIER UNIT CONVERTION EQUATIONS 13. Unit Conversion Equations and Lookup Table VRMS 13.1 Unit Conversion Equations Unit conversion VRMS à Equation dBu VRMS à dBV dBu à VRMS dBV à VRMS 4Ω 8Ω VRMS à VPeak 2Ω 2,7 Ω VRMS à Output power 13.
14 14. Warranty Information Q - P O W E R 14 | POWER AMPLIFIER WARRANTY 14.4 How to Obtain Warranty Service You must notify your dealer / distributor of your need for warranty service. All components must be shipped in the original packaging. 14.5 CAMCO Product Improvement CAMCO reserves the right to improve the technical standard of its products without giving prior notice. If in any doubt, please consult your dealer / distributor or contact CAMCO directly for clarification. 14.
Q - P O W E R 14 | 15 POWER AMPLIFIER SERVICE INFORMATION 15.
16 / 17 Q - P O W E R 14 | POWER AMPLIFIER MAINTAINCE INFORMATION / DECOMMISSIONING 16. Maintenance Information 17. Decommissioning Cleaning and servicing the inside of the amplifier must never be carried out by unqualified personnel. The amplifier must never be opened by unqualified personnel. During the decommissioning process of the amplifier, all legally prescribed rules and procedures must be adhered to.
Q - P O W E R 14 | POWER AMPLIFIER COMPANY INFORMATION Company information Mailing address: CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany Telephone: +49 (0) 27 62 / 4 08-0 Facsimile: +49 (0) 27 62 / 4 08-10 Internet: www.camcoaudio.com E-Mail: postmaster@camcoaudio.com USER MANUAL www.camcoaudio.
Q - P O W E R 14 | POWER AMPLIFIER CHANGES MADE TO THE AMPLIFIER / NOTICES Changes Made to The Amplifier / Notices l NOTE / IMPORTANT Please consider that any changes made to the amplifier have to be documentated in writing and passed on to the buyer in the event of resale! 38 / 42 www.camcoaudio.
Q - P O W E R 14 | POWER AMPLIFIER CHANGES MADE TO THE AMPLIFIER / NOTICES USER MANUAL www.camcoaudio.
Q - P O W E R 14 | POWER AMPLIFIER SECURITY COVER TEMPLATE Hole template for Volume Control Security Cover 40 / 42 www.camcoaudio.
www.camcoaudio.