Title BER LOOP BACK
Summary
Transmit PRBS9 data on
LO Frequency at transmit level
and listen for transmissions in the next slot but one. Sends
reports as
BIT ERR1 back to the host once per second
(configurable). Highside reception is off and attenuation is set to
zero Default is single slot packets (configurable with
config_freq). Designed to be used with a second unit in
loop_back test mode.
Related Test
Spec Name
None, but note that this test allows transmission to and
reception from IUT in loopback test mode, with calculation of
BER to BT specification.
Called via BCSP channel 2
Test Arguments
LO Freq (Carrier Frequency MHz)= 2402 to 2480
Power (Ext, Int) = gain of external amplifier (if present) and
internal amplifier
. Ext value is specific to the design and Int
value is
0 to 63 (Default = 50).
Note
With a second unit execute
CFG UAP/LAP to set BT address
then execute
LOOP BACK, then execute CFG UAP/LAP to set
the same BT address on the EUT before executing
BER LOOP
BACK.
Return Data Nine reports as for BIT ERR1.
Exit Click on Reset Chip.
BER LOOP BACK Example Display