Cambium ePMP Quick Start Guide System Release Beta ePMP Series Model Numbers This Quick Start Guide may be referenced for the following Cambium ePMP equipment: Model Description N000900L001A ePMP Pwr Supply for GPS Radio - no cord (spare) N000900L002A ePMP Pwr Supply for non-GPS Radio - no cord (spare) C050900A011A ePMP GPS, Conn - 5 GHz - no power cord C058900A112A ePMP GPS, Conn - 5 GHz - US power cord - FCC version C050900A021A ePMP Conn - 5 GHz - no power cord C058900A122A ePMP Conn - 5 GH
ePMP Quick Start Guide About this Guide Thank you for choosing Cambium Networks for your Point-to-Multipoint networking solution.
Overview of ePMP Hardware ePMP Quick Start Guide Overview of ePMP Hardware This section describes the key components of the ePMP Access Point and Station modules. Access Point Hardware External antenna ports (50Ω, SMA) LED Indicators Removable Lower Shell (for Ethernet port access) Access Point LED Indicators Label Function POWER Lit green when power is applied to the device. GPS SYNC Lit green when the AP has acquired a valid synchronization signal from a CMM or from its internal GPS.
Overview of ePMP Hardware ePMP Quick Start Guide Station Hardware LED Indicators Mounting Bracket Removable Lower Shell (for Ethernet port access) Station LED Indicators 2 Label Function POWER Lit green when power is applied to the device. ETH1 Lit green when Ethernet link is established at 10 Mbps or 100 Mbps, and blinks as traffic is sent over “Main” Ethernet interface.
Powering On the Access Point ePMP Quick Start Guide Installing the Access Point The ePMP Access Point is designed to attach to a Cambium antenna or to be pole-mounted (for use with a nonCambium antenna).
Powering On the Access Point ePMP Quick Start Guide Pole-mounting the Access Point To install an ePMP Access Point with an aftermarket antenna, perform the following steps.
ePMP Quick Start Guide Installing the Station The ePMP Station is designed to be pole-mounted. The Station antenna and networking components are self contained, so an external antenna does not need to be installed.
Connecting to the Unit and Logging into the Web Management Interface ePMP Quick Start Guide Connecting to the Unit and Logging into the Web Management Interface To configure or monitor your ePMP networking equipment, log into the web management interface following the steps below: 4 1 Connect management PC Ethernet cable to power supply LAN port 2 Configure the management PC with an IP address in the 192.168.0.x subnet (for example, 192.168.0.100, subnet mask 255.255.255.0).
Configuring Quick Start Parameters (AP) ePMP Quick Start Guide Configuring Quick Start Parameters (AP) The Quick Start tab contains a simple listing of parameters required to configure a simple radio link and to configure requisite networking parameters. After configuring these parameters on the AP and STA and resetting both devices, the STA will be ready to associate (register) to the AP.
Configuring Quick Start Parameters (STA) ePMP Quick Start Guide Configuring Quick Start Parameters (STA) The Quick Start tab contains a simple listing of parameters required to configure a simple radio link and to configure requisite networking parameters.
Enabling GPS Synchronization ePMP Quick Start Guide Verifying Radio Connectivity Enabling GPS Synchronization There are two ways in which the AP may receive GPS synchronization signaling: Internal GPS (models C024900A011A, C050900A011A, C058900A112A): The ePMP access point contains an internal GPS chip and antenna for receiving synchronization pulse and data (location, date, and time) from GPS satellites.
Regulatory Compliance ePMP Quick Start Guide Cabling and ligntning protection The following practices are essential to the reliability and longevity of cabled connections: Use only shielded cables and connectors to resist interference and corrosion. For vertical runs, provide cable support and strain relief. Include a 2-ft (0.6-m) service loop on each end of the cable to allow for thermal expansion and contraction and to facilitate terminating the cable again when needed.
ePMP regulatory compliance ePMP Quick Start Guide USA and Canada specific information The USA Federal Communications Commission (FCC) has asked manufacturers to implement special features to prevent interference to weather radar systems that operate in the band 5600 MHz to 5650 MHz. These features must be implemented in all products able to operate outdoors in the band 5470 MHz to 5725 MHz.
ePMP regulatory compliance ePMP Quick Start Guide Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
ePMP regulatory compliance ePMP Quick Start Guide Approved Antenna Model Description Input Impedance C050900D003A 5 GHz Antenna for 90 Degree Sector, 17 dBi 50 Ω C050900D003A 5 GHz Antenna for 60 Degree Sector, 16 dBi 50 Ω FCC ID Industry Canada Cert Number Frequencies Module Families 20 MHz channels, centered on 5735-5840 in 5 MHz increments (within the 5725-5850 MHz ISM band) Z8H89FT0006 109W-0006 20 MHz channels, centered on 5480 – 5590; 5660 – 5715 in 5 MHz increments (within the 5470 –
Specifications ePMP Quick Start Guide Specific expertise and training required for professional installers To ensure that the ePMP equipment is installed and configured in compliance with the requirements of Industry Canada and the FCC, installers must have the radio engineering skills and training described in this section. This is particularly important when installing and configuring a ePMP system for operation in the 5.4 GHz UNII band.
Specifications ePMP Quick Start Guide Category Specification Product Model Number C050900P011A, C058900P112A Spectrum Channel Spacing Configurable on 5 MHz increments Frequency Range 5.250 GHz – 5.350 GHz, 5.470 GHz – 5.875 GHz (dependent upon Region Code setting) 5.0 GHz Channel Width 20 MHz Interface MAC (Media Access Control) Layer Cambium Networks Proprietary Physical Layer 2x2 MIMO OFDM Ethernet Interface 10/100/1000BaseT, half/full duplex, rate auto negotiated (802.
Specifications Category ePMP Quick Start Guide Specification Nominal Receive Sensitivity (w/ FEC) @ 20 MHz Channel, Per Port MCS Rx Sensitivity at 1% PER (dBm) Rx Sensitivity at 10% PER (dBm) MCS15 -68 -69 MCS14 -69 -70 MCS13 -71 -72 MCS12 -76 -77 MCS11 -79 -80 MCS10 -82 -83 MCS 9 -85 -86 MCS7 -70 -71 MCS6 -72 -73 MCS5 -73 -75 MCS4 -78 -79 MCS3 -81 -82 MCS2 -85 -86 MCS1 -88 -89 Maximum Deployment Range Up to 40 km (25 mi) Subscribers Per Sector 120 ARQ
Specifications ePMP Quick Start Guide Category Specification Antenna Beam Width 90º or 120º sectors, or Omni Transmit Power, per Chain 0 to +27 dBm (to EIRP limit by region) in 1 dB-configurable intervals Antenna Gain 17 dBi Horizontal and Vertical Physical Wind Loading 190 km/hour (118 mi/hour) Antenna Connection 50 ohm, SMA Environmental IP54 Temperature -30ºC to +55ºC (-22ºF to +131ºF) Weight .521 kg (1.15 lbs) without antenna 1.92 kg (4.
Specifications ePMP Quick Start Guide Station (STA) Category Specification Product Model Number C050900P031A, C058900P132A Spectrum Channel Spacing Configurable on 5 MHz increments Frequency Range 5.250 GHz – 5.350 GHz, 5.470 GHz – 5.875 GHz (dependent upon Region Code setting) 5.0 GHz Channel Width 20 MHz Interface MAC (Media Access Control) Layer Cambium Networks Proprietary Physical Layer 2x2 MIMO OFDM Ethernet Interface 10/100BaseT, half/full duplex, rate auto negotiated (802.
Specifications Category ePMP Quick Start Guide Specification Nominal Receive Sensitivity (w/ FEC) @ 20 MHz Channel, Per Port MCS Rx Sensitivity at 1% PER (dBm) Rx Sensitivity at 10% PER (dBm) MCS15 -68 -69 MCS14 -69 -70 MCS13 -71 -72 MCS12 -76 -77 MCS11 -79 -80 MCS10 -82 -83 MCS 9 -85 -86 MCS7 -70 -71 MCS6 -72 -73 MCS5 -73 -75 MCS4 -78 -79 MCS3 -81 -82 MCS2 -85 -86 MCS1 -88 -89 Maximum Deployment Range Up to 40 km (25 mi) Subscribers Per Sector 120 ARQ
Specifications ePMP Quick Start Guide Category Specification Transmit Power, per Chain 0 to +27 dBm (to EIRP limit by region) in 1 dB-configurable intervals Antenna Gain 16 dBi Horizontal and Vertical Physical Wind Loading 190 km/hour (118 mi/hour) Antenna Connection 50 ohm, SMA Environmental IP54 Temperature -30ºC to +55ºC (-22ºF to +131ºF) Weight 4.94 kg (10.9 lbs) Dimensions (H x W x D) Radio: 252 x 117 x 78 mm (9.9” x 4.6” x 3.
Important safety information ePMP Quick Start Guide Safety Notices This section describes important safety and regulatory guidelines that must be observed by personnel installing or operating ePMP equipment. Important safety information To prevent loss of life or physical injury, observe the safety guidelines in this section. Power lines Exercise extreme care when working near power lines. Working at heights Exercise extreme care when working at heights.
ePMP Quick Start Guide Minimum separation distances Install the AP/STA so as to provide and maintain the minimum separation distances from all persons. The minimum separation distances for each frequency variant are specified in the ePMP User Guide. Freq. Antenna Band 5 GHz OFDM Variable d P G S Integrated STA, 16 dBi patch 0.199 W (23 dBm) 39.8 (16 dB) 10 2 W/m Connectorize d AP, with 17 dBi Sector Antenna and 1dB cable Loss 0.100 W (20 dBm) 39.
/ ePMP Quick Start Guide Cambium Networks Cambium Networks provides professional grade fixed wireless broadband and microwave solutions for customers around the world. Our solutions are deployed in thousands of networks in over 153 countries, with our innovative technologies providing reliable, secure, cost-effective connectivity that’s easy to deploy and proven to deliver outstanding metrics.