/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki LMU42x0 Hardware & Installation Guide 1 change (https://puls.calamp.com/w/index.php?title=LMU 42x0_Hardware_%26_Installation_Guide&oldid=4791&diff=cur) in this version is pending review. The stable version (https://puls.calamp.com/w/index.php?title=LMU42x0_Hardware_%26_Installation_Guide&stable=1) was checked (https://puls.calamp.com/w/index.php?title=Special:Log&type=review&page=LMU 42x0_Hardware_%26_Installation_Guide) on 10 June 2014.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 4.5.1 Activating a CDMA LMU42x0™ – Verizon 4.5.2 Activating a CDMA LMU42x0™ – Sprint 5 Installing the LMU 5.1 Preparing for Installation 5.2 Plan The Installation 5.2.1 Size and Placement of LMU Unit 5.2.2 Placement of Antennas 5.2.3 Access to the SIM (Subscriber Identity Module) Card 5.2.4 Protection from Heat 5.2.5 Visibility of Diagnostic LEDs 5.2.6 Cable Length 5.2.7 Moisture and Weather Protection 5.2.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Welcome to the LMU42x0™ Hardware and Installation Guide. This manual is intended to give you information on the basic setup and installation of the CalAmp LMU42x0™ product(s) including hardware descriptions, environmental specifications, wireless network overviews and device installation. 1.1 About This Manual The LMU42x0™ is one of the most flexible economy mobile tracking hardware products available.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki The LMU42x0™ features CalAmp's industry leading advanced onboard alert engine that monitors vehicle conditions giving you the most flexible tracking device in its class. The PEG™ (Programmable Event Generator) application supports hundreds of customized exceptionbased rules to help meet customers' dynamic requirements.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Basic System Architecture 2.2 Component Descriptions 2.2.1 Wireless Data Network The Wireless Data Network provides the information bridge between the LM Direct™ server and the LMU 42x0™. Wireless data networks can take a variety of forms, such as cellular networks, satellite systems or local area networks. Contact the CalAmp sales team for the networks available to the LMU42x0™. 2.2.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki software. Such examples could include instant messaging between vehicles or a central office, invehicle mapping or driving directions, email or database access. In most of these cases you will be using the LMU 42x0™ as a wireless modem as well as a vehiclelocation device. 2.2.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Electrostatic Discharge (ESD) Electrostatic discharge (ESD) is the sudden and momentary electric current that flows between two objects at different electrical potentials caused by direct contact or induced by an electrostatic field. The term is usually used in the electronics and other industries to describe momentary unwanted currents that may cause damage to electronic equipment.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 3.1.2 Battery Backup devices Please properly dispose of the battery in any of the CalAmp products that utilize one, do not just throw used batteries, replaced batteries, or units containing a backup battery into the trash. Consult your local waste management facility for proper disposal instructions. 3.1.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Electromagnetic Compatibility (EMC) EMC compliant for a ground vehicle environment SAE Test: SAE J1113 Parts 2, 12, 21 and 41 Operating Voltage Range The LMU42x0™ supports vehicles with 12 or 24 VDC systems including transients and electrical system noise; this includes ranges from 7 to 32 VDC. Electrostatic Discharge (ESD) No damage or performance degradation after the ESD disturbance.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki LMU4200™ Block Diagram 3.3 LMU42x0™Connectors The LMU42x0™ offers 5 connectors to access power, I/O, serial communications and other expansion capabilities. These connectors are: Primary Power Connector I/O Connector Serial Port Connector – Host/Aux1 Serial Port Connector – Aux 2 Expansion Connector (only available on 4200/4250, not on 4x20 devices) https://puls.calamp.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki LMU42x0™ Connectors 3.3.1 Power Connector The LMU42x0™ uses a 4 pin Molex 430450402 connector as its power connection. The pin out is as follows: 1 Signal Name VIN 2 GND Ground Black Ground 3 ADC1 Analog to Digital Input 1 Green Input 4 INPUT 0 Input 0 / Ignition Sense – Digital Input White Input Pin Power 5C888 Color Red Input or Output Power / Input Description https://puls.calamp.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki LMU42x0™ Header (looking into LMU) 3.3.2 I/O Connector The LMU42x0™’s features expanded I/O capabilities via its 22Pin Molex 430452202 connector. Its pinout is as follows: https://puls.calamp.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Description 5C889 Color 1 Signal Name Input 1 Input 1 – Digital Input Blue Input or Output Input 2 Input 2 Input 2 – Digital Input Orange Input 3 Input 3 Input 3 – Digital Input Violet Input 4 Input 4 Input 4 – Digital Input Gray Input 5 Input 5 Input 5 – Digital Input Green & White Input 6 Input 6 Input 6 – Digital Input Blue & White Input 7 Input 7 Input 7 – Digital Input Black & White Input 8 1BB T Data
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 3.3.3 Expansion Port The LMU42x0™’s features expanded I/O capabilities via its 16Pin Molex 430451600 connector.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 3.3.4 Serial Interface Connectors The LMU42x0™ offers 2 serial interface connections (Host/Aux1 and Aux 2) on its front face. These are provided via 2 Molex 436500501 connectors using the following pin outs. Pin 1 Signal Name VIN_FILT Description Filtered LMU Power 1333375 Color Red Input or Output Power Supply 2 VCC3V3 3.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki jPOD™ Vehicle Bus Adaptor The CalAmp jPOD Adapter is a J1939 compliant device that reads the parameters broadcast in the J1939 bus, processes them and provides filtered vehicle data to the LMU42x0™. A script is written using a special software tool and loaded into the jPOD. This script defines the specific parameters (PGNs/SPNs) to read, how to process them and how to send them to the host. The script does not send any requests onto the bus.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki jPOD™ Vehicle Bus Adaptor 3.3.6 Serial Adapter To add a host serial adapter to the LMU2610™ there is 1 additional part: Part Number 1333375: Serial Adapter. 3.3.7 Accessories See the Harness Diagrams page for more information on LMU accessories, and supported products table. 3.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Input 3: Generic Digital Input (Biased high or low/ S158 Bit 3) Input 4: Generic Digital Input (Biased high or low/ S158 Bit 4) Input 5: Generic Digital Input (Biased high or low/ S158 Bit 5) Input 6: Generic Digital Input (Fixed bias high) Input 7: Generic Digital Input (Fixed bias high) Input 8: Motion Sensor Input 9: VBUS Active Input 10: Pwr State Input 11: Vbatt Low Analog to Digital Inputs A/D 0: External Power Supply Monitor A/D 1: Gen
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki the vehicle’s ignition status to provide for flexible power management. The other two inputs may be used to sense vehicle inputs such as cooling unit operation, a hidden driver “Panic” switch, taxi onduty/offduty meter status or many others. The ignition input is pulled to ground through the 10k resistance, where the other inputs can be configured to be normally High (i.e. pulled to +12v through a 10k resistor) or Low (i.e.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Sample Input Wiring 3.6.3 Outputs https://puls.calamp.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki The LMU’s and ioPOD;s outputs are designed to drive external relays. These outputs provide a highcurrent, opencollector driver that can sink up to 150 mA each. These drivers may be used to drive external relays that can then control vehicle functions such as door locks, fuel shutoff valves, sirens and lights. If additional current is required to drive the relays, external circuitry can be added to source the current.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 4 Configuration and Activation This section details how to quickly get an LMU42x0™ provisioned and configured to point at a specific server. It is assumed that a PEG script has already been created and is being managed through LMU Manager or PULS™, the CalAmp Maintenance System. We are making three assumptions to simplify the setup process: You have created, installed and configured an LM Direct™ Server to receive messages from the LMU 42x0™.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki AT$APP PARAM 2319,0,ddd.ddd.ddd.ddd AT$APP PARAM 768,0,ddd.ddd.ddd.ddd AT$APP PARAM 769,0,ppppp (32‐bit products only) Where ddd.ddd.ddd.ddd is the publicly addressable IPV4 address of your LM Direct™ server and ppppp is the UDP port number. 4. Alternatively if a URL has been set up for your LM Direct™ server, the LMU may be programmed with: AT$APP PARAM 2319,0,myURL.MyCompany.Com Where myURL.MyCompany.com is the URL assigned to the server.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki For certain operators, the LMU can autopopulate the APN, username and password settings based on the Mobile Country Code (MCC) and the Mobile Network Code (MNC) of the SIM. Upon inserting a new SIM the APN, username and password will switch to the new SIM card's defaults if the MCC and MNC values change.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Telstra Australia (MCC 505, MNC 01, 11, 71, 72) o APN 0 & 1: telstra.internet Vodafone Ireland (MCC 272, MNC 01) o APN 0 & 1: isp.vodafone.ie o Username: vodafone o Password: vodafone Vodafone New Zealand (MCC 530, MNC 01) o APN 0 & 1: internet o Username: guest o Password: guest Vodafone UK (MCC 234, MNC 15) o APN 0 & 1: internet o Username: web o Password: web Unless otherwise stated, the username and password will be set to “dummy”.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki PULS (after the devices have connected to the network and sent in their first ID Report). See the PULS Users Guide for more information. If you do happen to have a SIM, the operator will ask for the IMSI and ICCID (Integrated Circuit Card Identifier) along with the IMEI of the LMU. Again, in return you should get a list of IMSIs and Phone Numbers. The IMEI, IMSI and ICCID are all available through the ATI1 command.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki GSM Registered: GPRS Registered: Connection: RSSI: BER: Channel: Cell ID: Base Station ID: Local Area Code: Network Code: Country Code: IMEI (Modem S/N): IMSI (SIM S/N): Phone Number: GPRS APN: Quality of Srvc: GSM Class: Yes Yes Yes ‐70 dBm 0 0 0 0 0 38 310 500167110060440 310380100521849 IP:Public 1,0,0,3,0,0 B 4.4 Accessing the SIM The SIM carrier is located on the right side of the LMU42x0™ underneath the wireless modem (GSM or HSPA).
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 4.5 Activating a CDMA LMU42x0™ Check with the CalAmp Sales team for availability of the LMU42x0™ with CDMA modems. For CDMA devices, the activation sequence you will use varies from carrier to carrier. Each of the supported carriers is documented below. To obtain an account, a CDMA carrier will generally ask for three things, the Manufacturer, the Product Type and the ESN. Obviously the first two items are answered by “CalAmp LMU”.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Note that the Phone Number should match the MDN value the carrier gave you. The last 10 digits of the IMSI field should match the MIN/MSID value they gave you. For devices that have had previous activations, an OverTheAir activation process may be manually started using a single AT Command: AT$APP MODEM UPDATE This command is also used to initiate an OverTheAir PRL Update for devices that are already provisioned.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki the IMSI field should match the value you used in step 3 or 4. 5 Installing the LMU The installation of the LMU and its antennas can have a major impact on the LMU’s performance. It is recommended that installers be familiar with the installation of GPS and cellular devices and are comfortable in a vehicle environment. 5.1 Preparing for Installation Be sure you have received all the LMU components you need.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki The dimensions of the LMU should be taken into account, particularly when installing in a vehicle: Whether you intend to place the LMU under a seat or into a cavity behind the vehicle’s interior molded trim, be sure the LMU will fit before drilling any holes or running cable Be certain that the cables running to the LMU will not be bent or constricted. Damage to the cables may impede the LMU’s performance.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Examples of good and poor GPS antenna placements The received signal levels at the GPS antenna from the satellites are very low in power (approximately 136 dBm), so any blockage of the antenna can affect the quality of the location computed by the receiver. Kinks or tight knots in the antenna cable can also prevent the GPS receiver from operating properly.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Examples OK(Yellow) and Poor(Red) internal antenna placements 5.2.3 Access to the SIM (Subscriber Identity Module) Card When used in a GSM or iDEN network, each LMU uses a Subscriber Identity Module (SIM) card, which should be inserted before you install the LMU for the first time. The SIM card is attached to the mainboard inside the housing of the LMU unit.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Do not cut cables. Instead, coil any excess cable length, making sure not to crimp or flatten the antenna cable. 5.2.7 Moisture and Weather Protection The LMU unit must be located where it will not be exposed to moisture or water.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki For best results, it is strongly recommended that the LMU connection be on its own circuit. Connect the power input directly to the vehicle battery if possible and protect the circuit with an inline fuse. If you must connect through the fuse box, use standard commercial wiring practices to create a permanent installation rather than using pressin fuse clips or other temporary measures. DO NOT connect the power cable to the LMU at this time. 5.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Window Mount Antenna Location 5.3.5 Typical Connection Sequence Attach the cable from the GPS antenna. Connect the cable from the Comm.. antenna Connect any peripherals to the LMU Plug in the power harness. The physical installation of the LMU hardware is now complete. Completed Install – separate antennas Completed Install Internal antennas https://puls.calamp.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 5.4 Installation Verification In many cases it is desirable to verify that an installed LMU42x0™ is working properly. That is, installers should verify that the GPS and communications functions of the LMU42x0™ are working properly before departing the installation site. In more robust cases, some key configuration settings such as the Inbound Address and URL should also be verified.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Please note that it may take several seconds (or longer) for the LMU42x0™ to communicate with the modem and acquire the wireless network. 5.4.2 GPS Verification The next step is to verify that the GPS receiver is seeing enough satellites to obtain a valid GPS position. Again, installers have two choices on how to perform this verification. First, like the Comm Verification, there is a GPS status LED (i.e.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki The installer will need to verify with a backend technician that the, URL (myURL.myCompany.com ), IP address (ddd.ddd.ddd.ddd) and port () are correct. The second step is to verify that the LMU42x0™ is sending data. The best way to do this is to force the LMU 42x0™ to send in an unacknowledged Event Report (i.e.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki o : This is the signal strength the wireless modem sees from the network. In general the LMU is at least scanning for the network if the RSSI is not 113. o [./d/D]: If the character ‘D’ is present, it indicates the LMU had a data session established when it responded to the status request. For the 8Bit product line an upper case ‘D’ indicates both the Inbound and Maintenance sockets are ready.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki field indicates the type of fix. The Fix Status types are detailed in the LM Direct Reference Guide. INP: o : This field details the current state of each of the LMU’s discreet inputs. This field is always 8 characters long. The left most character represents the state of input 7 where the right most represents the state of input 0 (i.e. the ignition). A value of 1 indicates the input is currently in the high state.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki 6 License Agreement FOR SOFTWARE, APPLICATION PROGRAMING INTERFACES (APIs) & DOCUMENTATION IMPORTANT: DO NOT INSTALL OR USE THE SOFTWARE OR DOCUMENTATION UNTIL YOU HAVE READ AND AGREED TO THIS LICENSE AGREEMENT. This is a legal agreement between you, the Customer, and CalAmp DataCom Incorporated (“CalAmp”). By installing and/or using the software or documentation, you are consenting to the terms of this License.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Duration: This License Agreement is effective from the day you install or start using the Software, or receive or download it electronically, and continues until terminated. If you fail to comply with any provision of the License, termination is automatic, without notice from CalAmp and without the necessity for recourse to any judicial authority.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Use Licenses: For each Server or Site License purchased, CalAmp grants the Customer the right to distribute Applications on a single Server or at a single Site, as the case may be, accessible to the number of individual users (not concurrent users) for which the Server or Site License has been purchased as evidenced by a CalAmp License Certificate.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki and service FOR A PERIOD OF NINETY (90) DAYS FROM THE DATE OF DEVELOPER LICENSE PURCHASE. CalAmp’s entire liability and your exclusive remedy as to defective media, Documentation or Related Material(s) shall be replacement of the media, Documentation or Related Material(s) by CalAmp. Each defective item, along with proof of license purchase and date, must be sent in a traceable manner to: CalAmp DataCom Inc., 1401 North Rice Ave.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki U.S. Government Protected Rights: The Software Documentation and Related Materials are provided with RESTRICTED RIGHTS. Use, duplication or disclosure by the Government is subject to restrictions as set forth in subparagraph ©(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227 7013 or subparagraphs ©(1) and (2) of the Commercial Computer SoftwareRestricted Rights at 48 CFR 52.22719, as applicable.
1/28/2015 LMU42x0 Hardware & Installation Guide PULS Wiki Compliance Statement (Part 15.105(b)) Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.