INTEGRA-TR™ WIRELESS MODEM FOR LICENSED SPECTRUM USER MANUAL PN 001-4008-000 REV 16 Revised December 2010
REVISION HISTORY REV DATE DESCRIPTION REV 0 Feb 2000 Initial Release as 001-4008-000. REV 1 Mar 2000 Updated manual format. REV 2 Jul 2000 Corrected FCC/IC numbers and added FM approval information. REV 3 Sep 2000 Updated Channel information in General Specifications - Section 1. REV 4 Nov 2000 Updated Typical Deviation in Section 4. REV 5 Jan 2001 Added CE information to Section 1.
Important Notice Because of the nature of wireless communication, transmission and reception of data can never be guaranteed. Data may be delayed, corrupted (i.e., have errors), or be totally lost. Significant delays or losses of data are rare when wireless devices such as the Integra-TR are used in a normal manner with a well-constructed network.
1 TABLE OF CONTENTS 1.1 Figures ........................................................................................................................................................................ 6 1.2 Tables .......................................................................................................................................................................... 7 2 PRODUCT OVERVIEW ........................................................................................................
3.4.10 COM Port Settings ............................................................................................................................................. 41 3.4.11 Swap COM Ports ............................................................................................................................................... 44 3.4.12 Port Statistics .....................................................................................................................................................
Figure 31 - Port Statistics Screen .............................................................................................................................................. 45 Figure 32 - Offline Link Test Screen ........................................................................................................................................ 46 Figure 33 - Offline Diagnostics Screen ...................................................................................................................
2 PRODUCT OVERVIEW 2.1 SCOPE OF MANUAL This document provides the information required for the operation and preventive maintenance of the Integra-TR integrated wireless modem. This manual is intended for system designers, installers and maintenance technicians. 2.2 GENERAL DESCRIPTION Integra-TR is a high-speed transparent integrated wireless modem. It is FCC refarming compliant and designed specifically to fit the needs of SCADA, telemetry and control applications.
2.3 PART NUMBER BREAKDOWN The following table provides a breakdown of the Integra-TR part number. Table 1- Integra-TR Part Number Breakdown 242-40W8-XYZ* W X Y 1 VHF 0 406.1-422 MHz 0 6.25 kHz 4 UHF 1 380-400 MHz 1 12.5 kHz 9 900 MHz 2 403-419 MHz 3 419-435 MHz (UHF), 406.1-440 MHz (UHF Dual Band) 3 5 25 kHz Dual Band 12.
Integra-TR DIN-rail Mounting Kit 250-5800-408 *Full-duplex base station Contact Technical Service VHF Antenna Kit Contact Sales Representative *For extended-transmit applications, the “TX Time out” timer must be turned off (set to “disable”) via the Field Programming Software. For information on accessories and options, contact your sales representative. In the United States phone 1-800-9927774 or 1-507-833-8819, for International inquiries phone 507-833-8819. 2.3.
Figure 2- Installation Dimensions Integra-TR User Manual Page | 11
2.3.4 CONFIGURATION Operating characteristics of the Integra-TR are configured by means of Integra-TR's Field Programming Software. The Field ® Programming Software is Windows based and requires a Windows 98 or later operating system running the Integra-TR Field Programming Software for both configuration and adjustment. 2.
Offline Diagnostics - Information is sent by a specific unit in response to an inquiry made locally or from another station. 2.7 FIRMWARE UPDATES The Integra-TR firmware resides in flash EPROM and is designed to allow field updates. Updates are done using a PC connected to the Integra-TR but do not require opening the unit. Updates will be coordinated by DRL’s Technical Service. 2.8 NETWORK APPLICATION Integra-TR is suited to a variety of network applications.
2.8.3 COMMON CHARACTERISTICS The networks described in this section share common characteristics: 1. 2. The DTE (data terminal equipment) network speed (1200, 2400, 4800, 9600 and 19,200 b/s) must be the same for all stations in a network. Transmission of online diagnostics may be enabled or disabled at any station or stations without affecting their ability to communicate with other stations. 2.8.4 POINT-TO-POINT SYSTEM Simple point-to-point connection is shown in Figure 4.
Figure 6 - Point-to-Multipoint System (full-duplex) Figure 7 - Point-to-Multipoint System (full-duplex repeater) 2.8.6 EXTENDING A LANDLINE (TAIL CIRCUIT) Integra-TR may be used to extend a landline circuit (giving access to difficult locations, etc.). This type of connection is called a “tail circuit” and is shown in Figure 8. The tail circuit assembly may be used in any of the network types described in the preceding sections.
Figure 9 - DCE Crossover Cable for RTS-CTS Mode Some point-to-point FDX landline modems or line drivers may require the use of DOX mode and an alternate pinout for DTR, DCD, CTS and RTS as shown in Figure 10.
2.9 SPECIFICATIONS These specifications are subject to change without notice. RF specifications are measured per TIA/EIA-603 with a psophometric baseband filter. General Frequency VHF UHF 900 MHz 132-174 MHz 380-400 MHz*, 403-512 MHz, 406.1-476 MHz Dual Band 928-960 MHz Channels Multi-channel capability under system PLC control Channel Bandwidth 6.25, 12.5 or 25 kHz models Operating Temperature Supply Voltage -30° to + 60° C 10 - 16 VDC maximum (nominal 13.
1 Cold Start: Time from DC power applied until unit is fully ready to receive or transmit data Warm Start Rx: In power saving modes (sleep or suspend), wake-up time for full receiver recovery 3 Warm Start Tx: In power saving modes (sleep or suspend), wake-up time for full transceiver operation 4 Tx Turn On Time: Typical Rx to Tx switching time for stable transmission 2 Transmitter VHF RF Power Output UHF 1 to 5 Watts, software adjustable Spurious and Harmonics <-57 dBc (-20 dBm) Frequency Tolerance
Interface Two outputs, requires external pull-up to 2 to 10 Vdc. Set via Offline Diagnostics Display 4 Bi-color status LEDs RUN/PWR/ CS/SYN, RX/TX, RD/TD Connectors RF SMA Female COM DE-9F SETUP/DIAG DE-9F Power - I/O Snap & Lock 4-Pin DC Power Jack Diagnostics Short ID, temperature, B+ voltage, local RSSI, remote RSSI, fwd and rev power, Rx Quality As for Online plus: Demodulated Signal Voltage, Analog Input Levels, Digital Outputs Online Offline Certifications VHF UHF FCC (6.
3 3.1 FEATURES AND OPERATION OVERVIEW This chapter describes the connections, indicators, and operating characteristics of the Integra-TR. This chapter is intended for system application and installation personnel. 3.2 FRONT PANEL The various front panel elements are described in the following sections. 3.2.1 ANTENNA CONNECTOR Antenna connector is a female 50-ohm SMA- type.
Table 3 - LEDs Color Functions*** RUN/PWR CS/SYN RX/TX RD/TD Green Normal operation Flash Yellow and Green Setup mode or loading new application or new bootloader Flash Red Firmware error* Red CPU or PROM failure* Off No RF RX carrier Green Receive carrier present Red (Reserved) Off No RF RX carrier Green Receiving network data Yellow Synthesizer unlocked Red Transmitter is on Off Idle Green RX data outgoing from RS-232 port Red TX data incoming at RS-232 port** * Contact Tec
9 to CTS delay in 4 ms DOX mode: CTS always asserted except when data overflow is detected Not internally connected, reserved RI 3.2.4.1 CONNECTOR PIN OUT The DE-9F pin out is shown in Figure 11 for reference. Figure 11 - COM and Setup Port Connectors Pin Locations 5 4 9 3 8 2 7 1 6 3.2.4.2 WIRE CONNECTION (DOX) For DTE that lack RTS control, Integra-TR can operate in DOX mode (Data Operated Transmit) with only Transmit Data, Receive Data and Ground (“3-wire interface”).
The Setup port uses a proprietary communications protocol designed to work with the Integra-TR Field Programming Software program. It is also designed to provide alpha numeric (ASCII) diagnostics information when connected to a PC terminal emulator. 3.3 REAR PANEL Figure 13 - Integra-TR Rear Panel The various elements are described in the following sections. 3.3.1 HEAT SINK The rear panel heat sink is essential for proper operation of the Integra-TR transmitter.
Note: The color of the power I/O cable wires are shown in parenthesis. If the I/O connections are not used the green and white wires should be cut back and/or taped to prevent contact (power I/O cable part number 697-4008001 see Table 2). 3.4 INTEGRA-TR FIELD PROGRAMMING SOFTWARE Figure 15 - Integra-TR Field Programming Software Startup Screen 3.4.
The Integra-TR Field Programming Software is the programming and diagnostics software for the Integra-TR wireless modem. The Field Programming Software allows the user to edit and program user programmable settings, interactively tune modem and RF parameters, and monitor diagnostic data from the Integra-TR. See Figure 15 for the Integra-TR Field Programming Software startup screen.
Modem type displays the type of modem (Integra-TR or Integra OIP). Modem type is a non-programmable parameter. Board Rev Board Rev displays the hardware revision of the modem board. Board rev is a non-programmable parameter. Short ID A user-defined number (from 1 to 254, 256 to 1023 - 255 is reserved) that identifies an individual unit in a network. Note: Firmware versions 2.10 and earlier only allow short IDs of (from) 1-254. Serial No. Serial No. displays the serial number for the modem board. Serial No.
Network Speed Network Speed selects the bit rate of the RF link between units. This can be different from the COM Port baud rate. This setting must be the same for all units in a network. 2400 b/s - selectable for quarter channel models Integra-TR only. 4800 b/s - selectable for quarter, half- and full-channel models of the Integra-TR and for full-channel models of the Integra-T. 9600 b/s - selectable for half- and full-channel models of the Integra-TR and for full-channel models of the IntegraT.
Using an External Program for Online Diagnostics The Setup port communicates with the field programming software using a proprietary protocol. However, if a terminal, or PC running terminal software is connected to the Setup port, online diagnostic information will be delivered in plain ASCII format. Initialization When powered on, the Integra will attempt to establish a link with the field programming software. If RTS is not exerted on the setup port, Integra-TR will immediately switch to ASCII mode.
Figure 17 - Suspend Mode Timing 3.4.2.2 COM/ANALOG OPERATING PARAMETERS The COM/Analog tab allows user programming of various COM Port and External input/output parameters (see Figure 18).
Tx Control This radio button selects the unit’s mode at the beginning of a transmission RTS – Request to Send DOX – Data Operated Transmit The Transmit Control default mode is DOX in which the unit begins a transmission as soon as data is presented to the COM Port. The optional mode is RTS in which the unit begins transmission only when the RS-232 RTS input pin of the COM Port is raised and continues transmitting until the RTS is dropped.
8 bits, no parity, 1 stop (default) 8 bits, no parity, 2 stop 8 bits, odd parity, 1 stop 8 bits, odd parity, 2 stop 8 bits, even parity, 1 stop 8 bits, even parity, 2 stop Data Fwd Timer 7 bits, no parity, 1 stop 7 bits, no parity, 2 stop 7 bits, odd parity, 1 stop 7 bits, odd parity, 2 stop 7 bits, even parity, 1 stop 7 bits, even parity, 2 stop This field selects the timing between data blocks in a transmission to accommodate some RTU’s special timing requirements: Normal - 15 ms option (default) Fast -
Figure 20 - Digital I/O Circuit Diagram Figure 21 - Integra Power I/O Cable From COM/Analog Operating Parameters screen (see Figure 18 and Figure 22), select Digital Output for the External I/O to be interfaced with user application. Figure 21 shows External I/O 2 (white wire) as chosen Digital Output. If desired, External I/O 1 (green wire) is utilized by choosing External I/O 1. Select Utilities from tool bar and select Offline Diagnostics.
For use in Integras not equipped with the cooling option - setting this option will configure the connection to be an analog input for 2 or 4 Channel Select Mode. If Channel Select 2 is NOT selected, this input and Channel Select 2 input selects between Channels 1, 2, 3 and 4. A low level (logic 0) is a voltage less than the Channel Select Voltage and a high level (logic 1) is a voltage greater than the Channel Select Voltage. The Channel Select Voltage is selected on the Radio Tab.
Note: Multi-Channel operation is available in modem firmware 2.20 or later. Tx Controlled Fan Timeout Tx Controlled Fan Timeout is used to set the interval of time the unit will keep the fan turned ON after a transmission is completed. The range is 5 to 255 seconds in 1 second intervals.
voltage greater than the Channel Select Voltage. Channel Select Voltage is selected on the Radio Tab. For 2 Channel Select Mode, a low level input will select channel 1 and a high level will select Channel 2. For 4 Channel Select Mode, see Table 7. Note: When configured as a Digital Output, the open collector transistor requires an external pull-up (i.e., resistor) to a voltage of 2 to 10 volts. Note: Multi-Channel operation is available in modem firmware version 2.20 and later.
Tune Range For UHF Range 0 25 kHz units only: Tune Range allows setting of the Integra-TR to the low or high end of the frequency (242-4048-030: 406.1-422 MHz Low Rx, 242-4048-031: 414-430 MHz High Rx). Transceiver Type These radio buttons configure the transmitting and receiving characteristics of the unit according to the type of network application: Tx Only - For use in a full-duplex application to disable receptions on the unit used as the transmitter.
the presence of noise, inter-modulation, or other sources of interference (i.e. for ambient noise at -100 dBm, set the Carrier Sense for -95 dBm). Tx Timeout Tx Timeout is used to set maximum period of time the unit will allow in a transmission. The range is 0 to 120 seconds in 1 second intervals (0 being disabled). Tx Timeout is used to protect both the unit and the network in case a transmitter becomes stuck on the air.
The Frequencies Tab allows the user to program the radio channels (Frequency Pairs). Rx Frequency Rx Frequency designates channel receive frequency. Tx Frequency Tx Frequency designates channel transmit frequency. There are 6 VHF splinter channels available for quarter-channel VHF (6.25 kHz) Integras. The frequencies for these splinter channels are: 154.456250 MHz 154.463750 MHz 154.471250 MHz 154.478750 MHz 173.203750 MHz 173.
The Select Version Reset utility is accessed from the Edit pull-down menu. Selecting Version Request causes the Integra-TR Field Programming Software to display information about the version of the Integra-TR hardware and firmware (see Figure 25). Figure 25 - Version Request Screen 3.4.4 LIST INFORMATION The List Information utility is accessed from the Edit pull-down menu. List Request is a diagnostic tool for the modem’s firmware.
The Program Comment/ID utility is accessed from the Edit pull-down menu. The Program Comment/ID field allows the user to program a Short ID and/or Comment. This function is used if the Integra-TR to be programmed was cloned from another unit (See Figure 28). Figure 28 - Program Comment/ID Screen Short ID A number (from 1 to 254 and 256 to 1023 - 255 is reserved) that identifies an individual unit in a network. Program Short ID Clicking this button programs the new Short ID.
ID, Comment and Remote/Master settings will be changed - verify correct ID, Comment and Remote/Master BEFORE clicking OK). At the completion of programming, the ID Number will automatically be incremented. 3.4.8 READ PARAMETERS The Read Parameters function allows the user to view the programmable parameters that are currently programmed in the Integra-TR. 3.4.
3.4.10.1 PRIMARY COM PORT PARAMETERS COM Port Selects COM Port number (COM 1-4) for the Primary and Secondary COM ports (see Figure 30). Baud Rate Selects the communication speed for Primary and Secondary COM Ports. Data Bits Selects the number of data bits (7 or 8) transmitted or received for the Primary and Secondary COM Ports. Parity Selects transmission or reception of any Parity Bits for the Primary and Secondary COM Ports.
Swap COM Ports Selecting the Swap Com Ports button moves the Secondary COM Port settings to the Primary COM Port (and moves the Primary COM Port to the Secondary settings). Since Integra-TR programming is done through the Primary COM Port, this is useful when two units are connected to the Primary and Secondary COM Ports. A Swap COM Ports allows the second unit to be programmed without switching programming cables. Swap COM Ports is also selectable from the Utilities drop-down menu. 3.4.10.
TCP/IP Response The TCP/IP Response allows the user to select the Response Time (in seconds) to allow for the Unit to respond to Programming Commands over a TCP/IP Connection. The value of this may require the use of the About Utility. By pinging the destination IP Address, the utility will give back Minimum / Maximum / Average Times it takes to send and receive a packet over the TCP/IP Connection. A safe value will be to use the Maximum Time (in seconds).
Ports allows the second unit to be programmed without switching programming cables. Swap COM Ports is also selectable from the Port Settings Primary and Secondary Port screens. 3.4.12 PORT STATISTICS Port Statistics are accessed from the Utilities pull-down menu and show the current parameters of the PC’s Primary and Secondary COM ports. Figure 31 - Port Statistics Screen Baud Rate Baud Rate shows the current setting for the utilized COM port.
Bytes Transmitted shows the number of bytes (characters) transmitted since the port was last opened. Bytes Rx’ed Bytes Received shows the number of bytes (characters) received since the port was last opened. Framing Errors Framing Errors shows the number of Framing Errors received since the port was last opened. 3.4.13 OFFLINE LINK TEST The Offline Link Test utility is accessed from the Utilities pull-down menu.
An Offline Link Test returns the following statistics: Blocks Tx’ed to Remote Blocks Tx’ed to Remote displays the number of data blocks transmitted to the remote unit. Responses from Remote Responses from Remote displays the number of responses heard from the remote unit. Blocks Rx’ed from Remote Blocks Rx’ed from Remote displays the number of data blocks received from the remote unit.
Block Delay (s) allows the user to determine the delay between the transmission of data blocks in 0.25 second intervals (0.00 to 10.00 seconds). Clear Clear allows the user to clear the display (blocks transmitted, responses received, blocks received and link quality). Start Start is used to begin the test. Pause Pause is used to pause the test and allows the user to resume the test at a later time. Save The Save button allows the user to save the current Offline Link Test results to a file. 3.4.
Unit ID: the Short ID of the unit sending diagnostics. RSSI Level: Received Signal Strength Indication (in dBm). Battery Voltage: supply voltage. Temperature: internal case temperature (in Celsius). Forward Power: Forward Power (in watts or dBm). Reverse Power: Reverse Power (in watts or dBm). Preamble Good: the number of correctly decoded transmissions received in the last 15. Used with Preamble Total, this serves as an indication of how well the unit is receiving data.
The Remote ID button allows the user to send diagnostic commands to any specific remote unit and obtain its diagnostic information. The Remote ID is selected from the list of Remote IDs set up in the Diagnostic IDs and Alarms screen. Diagnostic Select / Selected Remote ID This button allows the user to gather Offline Diagnostics from the selected Remote ID only.
Online Diagnostics are accessed from the Utilities pull-down menu. Online Diagnostics are transmitted by each unit in a network before the user’s data is transmitted. All units must be programmed with the Online Diagnostics parameter found on the Setup Modem/Radio Parameters screen to receive Diagnostics from a system. The unit that the computer is interfaced with will output Online Diagnostics as they are received. Using Online Diagnostics does not require suspension of network operation.
Time is the time stamp when the diagnostics were received. Filter Filter allows the user to filter Short IDs. The following options are available: Off (All IDs): no IDs are filtered out. ID List: only the IDs in the Filter ID List are shown. Selected ID: only the selected ID in the Filter ID List is shown. Display Display allows the user to format on screen data. The following options are available: Scroll (by time): displays the diagnostics as they are received.
ID Entry and List ID Entry: Allows the user to add Short IDs to the ID List. The range of this field is 1 to 1023 (ID 255 is reserved). A Short ID is added to the ID list by hitting Enter or by pressing the Add ID button. ID List: Allows the user to select a Short ID from the list to delete. A Short ID is deleted from the list by pressing the Delete ID button. IP Address: IP Address allows the user to receive diagnostics through a serial to Ethernet converter with this IP Address.
The Save As button allows the user to save the current Diagnostic IDs and Alarms to a name different than the current file. OK Selecting OK closes the Diagnostic IDs and Alarms window. 3.4.17 USER TEST The User Test Utility is accessed from the Utilities pull-down menu. The User Test utility is an Offline function and requires suspension of network operation.
Reverse power (in watts or dBm). External I/O 1 Voltage on the External I/O 1 Input from the Power - I/O Connector (in volts). External I/O 2 Voltage on the External I/O Input from the Power - I/O Connector (in volts). Preamble Good The number of correctly decoded transmissions received in the last 15. Used with Preamble Total, this serves as an indication of how well the unit is receiving data. Preamble Total The number of total transmissions detected, maximum is 15.
Pressing the F6 key will cause the unit to go to receive on the programmed receive frequency. 3.4.18 PACKET TEST The Packet Test allows the user to simulate a Host/Remote polling environment. The Host will send out a packet to the Remote and the Remote will reply to the Master with the same packet information. This test is useful for testing the modem link. Figure 37 - Packet Test Screen Host Packets Tx’ed Host Packets Tx’ed shows the number of data packet the Host device sent to the Remote.
Remote to Host % shows the percentage of data packets the Remote device successfully sent to the Host. Overall % Overall % shows the percentage of Host received packets versus Host transmitted packets. # of Packets to Send # of Packets to Send is a programmable number to tell the Host how many data packets to send to the Remote. After the programmed number of data packets are sent, the transmission will automatically stop.
Pin Name DB-9 DB-25 Computer Rx Tx DCD RxD TxD DTR GND DSR RTS CTS RI 1 2 3 4 5 6 7 8 9 8 3 2 20 7 6 4 5 22 X X X X X X - X X X - X X X X - 3.4.19 ARRAY TEST Figure 38 - Array Test Screen The Array Test utility is used to send programmable length test packets. The packets are built using one of four possible patterns. Packets Tx’ed Packets Tx’ed shows the total number of data packets transmitted.
ASCII Pattern The ASCII Pattern Packet are 58 characters in length and have a sequence number at the beginning of each string, starting at 000, incrementing to 999 and wrapping around to 000 again.
Random Binary Pattern is 16 characters in length and contain random binary data. Packet Size Packet Size shows the number of data bytes in each packet (described in Pattern Descriptions above). # of Packets # of Packets shows the number of packets in each transmission. Packet Delay Packet Delay shows the amount of time (in seconds) to delay between each packet transmission (range is from 0.00 to 30.00 seconds in 0.25 second intervals).
Minimum Time displays the minimum amount of time taken for the Ping Packet to echo back from the Remote device (in milliseconds). Maximum Time Maximum Time displays the maximum amount of time taken for the Ping Packet to echo back from the Remote device (in milliseconds). Average Time Average Time displays the average amount of time taken for the Ping Packet to echo back from the Remote device (in milliseconds).
The packets will be 16 characters in length. The pattern used to build the packets will have the following format (in Hex): 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF 00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF --00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF Random Binary Pattern The packets will be 16 characters in length and contain random binary data. Packet Size Packet Size displays the number of bytes in each packet (described in Type of Data).
3.4.21 ASCII / HEX TERMINAL The ASCII Terminal Screens are accessed from the Utilities pull-down menu and allow the user to select an ASCII, Hexadecimal TCP Socket or UDP Socket Terminal Screen for the Primary and Secondary COM Ports (configured in the Port Settings screen - see Section 3.4.10) Data is sent according to the port configuration set up in the Port Settings screen. 3.4.21.
3.4.21.2 HEX TERMINAL Hex Terminal configurations include: Primary The Primary Hex Terminal screen selects a Hexadecimal Terminal screen to send and receive Hexadecimal data on the Primary COM Port (set up in the Port Settings screen). Secondary The Secondary Hex Terminal screen selects a Hexadecimal Terminal screen to send and receive Hexadecimal data on the Secondary COM Port (set up in the Port Settings screen).
3.5 INTEGRA-TR HELP FILES Integra-TR Field Programming Software’s online help files are accessed by the menu bar at the top of the Field Programming window. Figure 42 - Integra-TR Online Help Introductory Screen 3.6 OPTIMIZING YOUR SYSTEM Detailed system engineering is beyond the scope of this manual. However, there are some simple tips that can be used to optimize performance of a radio based SCADA or telemetry system.
Interpreting RSSI Readings Typical values of RSSI will be in the range of -110 to -60 dBm (depending on network speed), with higher values (i.e. less negative values) indicating a stronger signal. Reliability of data reception depends largely on signal strength. Good design practice calls for a minimum 30 dB “fade margin”, based on a threshold reception level of -107 dBm (1 uV) at speed of 9600 b/s. Experience indicates that this will give about 99.5% reliability.
4 CONFIGURABLE PARAMETERS 4.1 PARAMETER OVERVIEW The parameters used to configure the Integra-TR units are described in the Field Programming Software help file. Section 4 summarizes the Integra-TR parameter settings and their variations when used within a network.
Table 12 - Normal Factory Settings (Bases) Fields Full Duplex Base Integra-TR with other Integra-TR Redundant Integra-TR Full Duplex Base with Integra-TR/Integra-T RX Unit RX Units TX Unit TX Units Network Settings Station ID (CWID) Compatibility Mode Extended Preamble (ms) Network Speed Tx Online Diagnostics Unit Type Data Delivery Activity Time-out (sec) Disabled (OFF) Integra-TR 5 mS 19200 Full Channel 9600 Half Channel 2400 Quarter Channel Yes Master All 5 Integra-T / TR 0 mS 9600 Full Channel
5 DEFINITIONS Bit dribble Extraneous bits delivered at the end of a data transmission. Equivalent to a “squelch tail” in voice systems. Integra-TR does not have bit dribble. COM Port The Communications Port of Integra-TR. This port is configured as DCE and is designed to connect directly to DTE. CTS Clear to Send. An RS-232 output signal from Integra-TR indicating that it is ready to accept data (used in RTS mode). DCE Data Communications Equipment.
ABOUT CALAMP CalAmp is a leading provider of wireless communications products that enable anytime/anywhere access to critical information, data and entertainment content. With comprehensive capabilities ranging from product design and development through volume production, CalAmp delivers cost-effective high quality solutions to a broad array of customers and end markets. CalAmp is the leading supplier of Direct Broadcast Satellite (DBS) outdoor customer premise equipment to the U.S.
telemetry and asset tracking markets, private wireless networks, public safety communications and critical infrastructure and process control applications. For additional information, please visit the Company’s website at www.calamp.com.