CADI SmartSense SmartNode SMN-822W User Manual
CONFIDENTIAL Table of Contents Table of Contents ............................................................................................................................................................ 2 1. about SMN-822W ................................................................................................................................................. 5 1.1 Overview ............................................................................................................................
CONFIDENTIAL Regulatory Information For customers in U.S.A and Canada The SMN-822W (FCC ID: VPE-SMN-822W) has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
CONFIDENTIAL Battery Precautions Keep batteries away from children. Do not swallow batteries. Do not throw batteries into water. Do not throw batteries into fire. Do not short circuit, recharge, over-discharge, puncture, incinerate, crush or expose to temperature above the temperature rate of the battery. Do not replace battery with incorrect type. Incorrect type of battery replacement may cause risk of exposure. Battery should be dispose according to the instructions.
CONFIDENTIAL 1. about SMN-822W 1.1 Overview This chapter contains information about the SMN-822W including safety. Please make sure you read this entire instruction manual prior to using the SMN-822W. 1.2 Introduction Cadi’s SmartNODETM SMN-822W is part of Cadi’s range of WIFI sensor that is used for monitoring the utilization of hand rub. SMN-822W sensor is battery powered, designed to seamlessly fit with any existing hospital hand rub dispenser. SMN822W is a pressure activated sensor.
CONFIDENTIAL 1.3 Safety This section contains important safety information. You need to read and understand all warnings, cautions, and the operator’s manual prior to using the SMN-822W. 1.3.2 Potential Adverse Event There is no potential adverse event on using SMN-822W device. 1.3.2 Reported Adverse Event There is no reported adverse event on using SMN-822W device.
CONFIDENTIAL 2. Specifications 1 Power 1x A (3.6V) : Lithium Thionyl Chloride Battery (Non – Rechargeable) 2 Dimension 79(L) x 70(W) x26(H) mm Weight 158g (without fitting fixture) 3 Operating temperature -10°C - 50°C 4 Storage & Transport temperature range 0°C - 30°C 5 WIFI 2.4GHz 802.
CONFIDENTIAL 3. Installations and Maintenance The CADI SMN-822W should be installed and maintained only by authorized personnel. 3.1 Environment Requirement The environment where CADI SMN-822W is used should be in accordance with the requirements specified in specification. In addition, CADI SMN-822W should be used in an environment without excessive noise, dust, flammable or erosion substances. The device contains battery and it should not place near any heat source.
CONFIDENTIAL 4. Battery replacement instruction Pictures Procedures Open the battery compartment by releasing the screw. Make sure the O-Ring still intact on the battery compartment as shown.
CONFIDENTIAL Press the strain gauge sensing point. Press the weighing plate, if there is. Check the response of device by pressing the strain gauge. Make sure green LED is blinking on the press on strain gauge. Make sure there is blinking LED Close and tighten the battery compartment. Make sure O-ring is always intact in the grove. Tighthen the battery compartment with torque 3.0kgf.cm Tightening with torque 3.0kgf.
CONFIDENTIAL 5. Battery Status Indicator Battery normal: LED blinks green every 30 seconds.
CONFIDENTIAL 6.
CONFIDENTIAL 7. Technical Specifications Overview This chapter contains specifications for the SMN-822W and EMC information. 7.1 Electromagnetic Compatibility Requirements WARNING: The SMN-822W should not be used adjacent or stacked with other equipment and, if necessary, observe its operation to verify its normal operation during use. Refer to the Electromagnetic Immunity information in this chapter.
CONFIDENTIAL The above listed models are intended for use in the electromagnetic environment specified below. The customer or the user of the above listed models should assure that they are used in such an environment. Enclosure Port Immunity test Test Condition IEC 60601 Compliance level Electromagnetic environment guidance Electrostatic discharge (ESD) IEC 61000-4-2 ±8 kV Contact ± 2,4,8,15 kV Air ±8 kV Contact ± 15 kV Air Floors should be wood, concrete or ceramic tile.
CONFIDENTIAL The above listed models are intended for use in the electromagnetic environment specified below. The customer or the user of the above listed models should assure that they are used in such an environment.
CONFIDENTIAL Guidance and manufacturer's declaration - electromagnetic immunity The above listed models are intended for use in the electromagnetic environment specified below. The customer or the user of the above listed models should assure that they are used in such an environment.
CONFIDENTIAL Recommended separation distances between portable and mobile RF communications equipment and the above listed models The above listed models are intended for use in the electromagnetic environment in which radiated RF disturbances are controlled.
CONFIDENTIAL 7.2 IEC 60601‐1‐2 Compliance 7.2.1 Basic Safety The basic safety is ensured, if it fulfils the safety requirements of the standard IEC 60601-1, especially the requirements against electric shock, mechanical hazards and hazards out of over temperatures. 7.2.2 Essential Performance The equipment has no direct clinical function or essential performance according to IEC60601-1. 7.2.3 Intended Use The device was developed to detect use of hand rub by sensing the pressure applied on the device.