User's Manual

PartNoS0711011
Description:
InstallingaBudderflyadaptertransformsyourbuilding’sexistingwiringintothe“BudderflyOpenNetwork”andallowstheadapterto
monitorenergyconsumptionandcommunicatethedatatoafacilitycontroller.
Budderflyadaptorswillusetheexistingpowerlineforcommunicationandthusrequirenorewiring.
UsingourBudderflysoftware,you
canvisualizeconsumptiondataandmanageeachindividualadapter.
TheBudderflylightingswitchisacomponentoftheBudderflysysteman ddesigned toworkwithallotherBudderflydevices.Itisa
plugandplayreplacementforyourexistinglightingswitch.Onceinstalled,theBudderflyswitchesalsoactasrepeaters
toextendthe
rangeofthenetworkandincreaseefficiency.
Thisdeviceisdesignedforuseonlywithpermanentlyinstalledfixtures.
Installation:
TheBudderflyswitchmaybeusedinnewinstallationsortoreplaceanexistingwallswitch.Itisintendedtobeusedonlyasa2wayswitch.Thewiring schematicwillbeasperbelow:
1. Atthe circuit breakerorfuse panel, disconnect the powerfor all of the circuits in
theswitchjunctionbox..
2. DoubleCheckthatthepowerisOFFtotheswitchboxbeforecontinuingbytrying
toturnonthecontrolledload.
3. Removethewallplatefromtheswitchyou
arereplacing.Then,unscrewtheswitch
itselfandpullitoutfromthejunctionbox.
4. Disconnectthewiresfromtheswitchyouarereplacing.
5. FollowtheWiringinformationprovidedbelowtoconnectthewiresasfollows:
o ConnecttheGROUNDwire(usuallyBareCopperorGreen)tothe
Groundwireof
BudderflySwitch(Yellow&Green).
o ConnecttheLOADwire(usuallyBlack)thatgoestothelighttotheLOADwireof
BudderflySwitch(Red).
o ConnecttheLINEwire(usuallyBlack)thatcomesfromtheelectricalservicepanel
totheHOTwireofBudderflySwitch(Black).
o
ConnecttheNEUTRALwire(usuallyWhite)totheNeutralwireofBudderfly
Switch(White).
6. After you have connected all of the wires, ensure that all of the wire connectors
are firmly attached and that there is no exposed copper except for the GROUND
wire.
7. GentlyplaceBudderflyswitchinto
thejunctionbox,orientingtheunitwiththeLED
barontheleft.Then,screwtheswitchintoplace.
8. Reinstallthewallplate
9. Enablepowertotheswitchfromthecircuitbreakerorfusepanel
10. AfterthePowerLEDcomeson,testthat theswitchisworking properly
by turning
thelightonandoff
11. AddthedeviceaddresstotheBudderflywebapplication.
WARNING–ELECTRICALSHOCKHAZARD
TheBudderflyDualBandLightSwitchisintendedforinstallationinaccordancewiththeNationalElectric
CodeandlocalregulationsintheUnitedStates.
Ifyouarenotknowledgeableorcomforta blewithelectricalcircuitry,youshouldhaveaqualifiedelectrician
installtheBudderflyDualBandLightSwitchforyou.

Warning
RISKOFFIRE/ELECTRICALSHOCK/BURNS
ExerciseextremecautionwhenusingBudderflyswitchingdevicestocontrolappliances.
ToavoidtheriskofFire,ElectricalShock,Burnsorotherhazardswerecommendthefollowing:
InstalltheBudderflyswitchesindooronly.
NeverusetheBudderlyswitchestocontrolmedical
and/orlifesupportequipment.
DonotusetheBudderflyswitchestocontrolelectricheatersoranyotherapplianceswhichmaypresenta
hazardousconditionduetounattendedorunintentionalpoweroncontrol.
Never use the Budderfly switches with loads that exceed the maximum rating specified.
WARNING–ELECTRICALSHOCKHAZARD
TurnOFFthepowertothebranchcircuitfortheswitchandlightingfixtureat
theservicepanel.
AllwiringconnectionsmustbemadewiththePOWEROFFtoavoidpersonal
injuryand/ordamagetotheswitch.
WiringInformation
Important:BudderflySwitchisratedforandintendedtoonlybeusedwith
copperwire.
Use12AWGorlargerwiressuitablefor80
o.
Remove3/4"(1.9cm)ofinsulationfromeachwire.
Connectasfollows:Twiststrandsofeachendtightlytogether.Holdbare
endsofwirestogetherandpushfirmlyintowireNut.ScrewNutclockwise
makingsurethatnobareconductorshowsbelowtheconnector.
WARNING: If you are not sure
about any part of the above
instructions, consult a qualified
electrician.