mBSC-H DAS System Installation Manual Issue 5 mBSC-H DAS SYSTEM INSTALLATION AND OPERATIONS MANUAL
mBSC-H DAS System Installation Manual Issue 7 COPYRIGHT This document serves as the System Installation Manual for the BTI mBSC-H Fiber Distributed Antenna System (DAS) system. BTI reserves the right to change the contents without prior notice. No part of this document may be reproduced or utilized. © 2009-2013, BTI, All Rights Reserved REVISION HISTORY ISSUE NO.
mBSC-H DAS System Installation Manual Issue 7 Table of Contents 1 2 3 GENERAL INFORMATION ...................................................... 6 1.1 SAFETY PRECAUTIONS ............................................................................... 6 1.2 GLOSSARY AND ACRONYMS...................................................................... 7 INTRODUCTION ...................................................................... 8 GENERAL DESCRIPTION .................................................
mBSC-H DAS System Installation Manual Issue 7 4.2.6.1 Mechanical Installation Review ....................................................................................... 39 4.2.6.2 Electrical Installation Review ........................................................................................... 39 4.2.6.3 Field Status Test - Remote Unit LED Status Indicators ................................................... 39 4.2.7 Troubleshooting ..............................................................
mBSC-H DAS System Installation Manual Issue 7 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 Add a Site ............................................................................................... 78 Add a Host Unit ...................................................................................... 80 Configuring the Host Unit Hardware Card ........................................... 82 Map the IP Address to the NMS Software ............................................ 86 Adding a Master and/or a Slave Remote Unit .
mBSC-H DAS System Installation Manual Issue 7 1 GENERAL INFORMATION 1.1 SAFETY PRECAUTIONS Danger: Danger is used to indicate the presence of a hazard that will cause serious personal injury, death or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that may cause serious personal injury, possible death or substantial property damage if the hazard is not avoided.
mBSC-H DAS System Installation Manual Issue 7 13. This Unit complies with European standard EN60950. 14. Verify that all regulatory requirements have been met and that all system settings have been set according to the intended use. (Please see appropriate manufacturer product information materials.) 15.
mBSC-H DAS System Installation Manual Issue 7 2 INTRODUCTION This document provides the installation procedures for the BTI DAS system consisting of the DAS Host Unit, Remote Unit equipment and the Network Management System (NMS). It also provides for the initial configuration set-up, operation procedures and the software upgrade installation process for the Network Management System.
mBSC-H DAS System Installation Manual Issue 7 The Remote Units may consist of combinations of 700MHz, 850MHz, 1900MHz and 2100MHz frequencies and are available in 20 Watt, 40 Watt or 80 Watt output configurations. Each RU is designed to support a Single Frequency Band. For multi-frequency use, the system can be configured as multiple Master/Slave Remote Units. Each Master Unit can support a maximum of two slave RUs with a maximum of three RUs supported per fiber connection.
mBSC-H DAS System Installation Manual Issue 7 Figure 3-3. Network Management System Software Components Folder and Desktop Icon 3.1.3 Remote Unit The Single-Band Master Remote Unit, shown in Figure 3-4a, 3-4b, 3-4c and 3-4d, consists of an optical module (O/E), a downlink power amplifier, an LNA, and duplexer. The Optical module converts the downlink optical signal from the FIU module in the HU and splits the RF signal into 3 RUs.
mBSC-H DAS System Installation Manual Issue 7 Figure 3-4a. 20 Watt and 40 Watt Fan Cooled Remote Unit Figure 3-4b.
mBSC-H DAS System Installation Manual Issue 7 3.2 USER INTERFACE The user interface for each segment of the mBSC DAS System is designed to provide the most efficient interaction, installation and ease of use for the user. 3.2.1 Host Unit Interface Each interface module of the Host Unit, shown in Figure 3-5, is described in Table 3-1 below. Figure 3-5. Host Unit Interface Table 3-1.
mBSC-H DAS System Installation Manual Issue 7 uses SNMPv2.0 protocol to transmit automated traps to the operator's Network Operations Center for remote alarming and system queries. These two capabilities provide for centralized configuration and alarm monitoring of the entire system. Operational parameters, such as uplink and downlink, and gain can be set through the NMS server. Status information at each node is easily available.
mBSC-H DAS System Installation Manual Issue 7 Figure 3-7. NMS Command Console Table 3-2. Default Parameter Values Parameter Name Default Value Menu System Parameter SNMP No User Manager Name: Manager; Password: 1; Level: Supervisor User User Name: User; Password: 1; Level: Observer 3.2.3 Remote Unit Interface The interface of the Remote Unit consists of connectors and LEDs that are located on the bottom of the RU enclosure.
mBSC-H DAS System Installation Manual Issue 7 SLAVE Remote Unit: No Fiber Optic Cable connection with the Host Unit Interfaces with the Master Unit for downlink and uplink signal Unused ports (TX_OUT, RX_IN) are blocked with a cover. Figure 3-8. User Interface of MASTER Remote Unit Label Name ANT OPERATE TX_Out RX_In FIBER POWER DC_FAN VENT Table -3-3. Master Remote Unit User Interface Description Interface port for Antenna Feed line LED indicator for normal or critical fault status of the RU.
mBSC-H DAS System Installation Manual Issue 7 TX_Out (Slave 1) RX_In (Slave 2) POWER DC_FAN VENT RF output port to provide the input signal to the Slave Remote Unit when Dual or Triple Band application is configured RF input port to provide the output signal to the Master Remote Unit when Dual or Triple Band application is configured. Interface port for the AC 110/220V power cable Provides power to fan Port for the balance of pressure inside and outside of the enclosure 3.3 SPECIFICATIONS 3.3.
mBSC-H DAS System Installation Manual Issue 7 Server Specification Operating System Memory Storage Power Video Card Network Controller Specification Notes Microsoft® Windows® XP Professional 4GB (4 DIMM slots) DDR3 Cabled Hard Drive Options: 2.5" SATA SSD, SAS (10K), nearline SAS (7.2K) Maximum Internal Storage: 250G Single cabled power supply (250W) Matrox G200eW w/ 8MB memory One dual-port Broadcom BCM 5716 3.3.
mBSC-H DAS System Installation Manual Issue 7 4 INSTALLATION 4.1 SYSTEM INSTALLATION OVERVIEW This section provides instructions for installing the mBSC DAS system in an efficient, productive and customer friendly order. Each component of the mBSC DAS system is covered in its own installation section as follows: 4.2.
mBSC-H DAS System Installation Manual Issue 7 4.2 REMOTE UNIT INSTALLATION Danger: Wet conditions increase the potential for receiving an electrical shock when installing or using electrical power equipment. To avoid electrical shock, never install or use the electrical equipment in a wet location. Danger: Do not look into the end of the fiber optic cables. Exposure to laser radiation may result.
mBSC-H DAS System Installation Manual Issue 7 installation. Table 4-2 lists the mounting hardware provided by the manufacturer for a standard BTI pole mount installation kit. Additional hardware may be needed, depending on the site requirements, and may be ordered through Customer Service (Section 6). Table 4-2.
mBSC-H DAS System Installation Manual Issue 7 Wire cutters Wire Stripper Open End Wrench 1.25 inch/33mm (used for DIN connector) Hex Wrench 5mm (M6 screw) SAE Wrench 5/16 inch/8mm (the Slave Remote Unit connectors) 4.2.3 Unpacking And Inspection This section provides the instruction for receiving the equipment shipment, verifying all parts have been received and checking that no damage has occurred during transportation.
mBSC-H DAS System Installation Manual Issue 7 3. Begin removing the Remote Unit(s) from the Mounting Panel by unscrewing the two (2) M8 fasteners at the bottom bracket Interface end of the Remote Unit(s), Figure 4-4. Figure 4-4. Remove the two M8 Fasteners 4. Remove the single (1) M8 fastener from the top bracket Fan end of the Remote Units and then remove the two (2) M5 fasteners from the metal shipping bracket and discard the metal shipping bracket, Figure 4-5. Figure 4-5.
mBSC-H DAS System Installation Manual Issue 7 7. Verify receipt of hardware and fasteners using Table 4-2 8. Check each Remote Unit and accessories for broken or missing parts. If there is any damage or missing parts, contact BTI (Section 6) for an RMA and to reorder parts, if any replacement parts are required. NOTE: Check particularly for any damage to the power connection, the fins/fans, and the fiber optic cable connection on the Remote Unit Interface.
mBSC-H DAS System Installation Manual Issue 7 4.2.4 Mechanical Installation 4.2.4.1 Mechanical Safety Precautions Please read the general Safety Precautions contained in Section 1.2 Safety Precautions 1. Follow the procedures provided by the manufacturer when installing the Remote Unit. Do not install the Unit in a place or in a manner that does not meet the manufacturer's provided specifications. 2. Use the mounting hardware supplied by the manufacturer.
mBSC-H DAS System Installation Manual Issue 7 4.2.4.2 Install The Mounting Panel Use the following procedure to install the mounting panel on the pole: 1. Take one M12 screw and insert it loosely in one of the two top holes in the panel. Place the mounting panel against the pole as shown in Figure 4-6. 2. Place one of the two I-Beam or U-Beam brackets on the back side of the pole so that it aligns with the M12 screw. 3. Hand tighten the screw to hold it in place 4.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-7. The Mounting Panel secured tightly to a Pole 4.2.4.3 Install The Remote Unit On The Mounting Panel Use the following procedure to install the RU on the mounting Panel. 1. Verify that the attached side mounting brackets, as shown in Figure 4-8 are secure. 2.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-9. Secure Enclosure To the Side Mounting Bracket 4.2.4.4 Install The Shroud Cover The Remote Unit has a Shroud cover for thermal protection. Use the following procedure to install the Shroud cover on the enclosure: 1. Line up the slots at the top of the Shroud cover to the tabs at the top of the mounting panel as shown in Figure 4-10. 2. Gently lower the slots over the tabs and slide the cover down. The cover will be at an angle, Figure 4-11. 3.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-10. Install the Shroud Cover to the RU Figure 4-11.
mBSC-H DAS System Installation Manual Issue 7 4.2.5 Electrical Installation 4.2.5.1 Electrical Safety Precautions Please read the general Safety Precautions presented in Section 1.2 Safety Precautions 1. This Unit uses high voltages. Follow the instructions for installation provided in this manual to prevent serious accidents including loss of life, severe personal injury or extensive property damage. 2. The Unit must be grounded before connecting any power supply.
mBSC-H DAS System Installation Manual Issue 7 4.2.5.2 Grounding The Unit must be grounded and the integrity of the protective earth must be ensured. Connect an earth-bonding cable to the provided grounding connection on the equipment. Do not connect any additional external devices to the grounding connection. Figure 4-12. Grounding Connection 1. Uncover the RU interface by removing the Vandalism Protective Shield from the bottom of the Shroud Cover. 2.
mBSC-H DAS System Installation Manual Issue 7 Warning: Do not look into the end of the fiber optic cable. Do not look directly into the optical transmitter of any Unit or exposure to laser radiation may result. An optical power meter should be used to check the active fibers. Use the following procedure to connect the fiber optic cable: 1. Connect or splice the drop Fiber cable to the outside plant cable.
mBSC-H DAS System Installation Manual Issue 7 NOTE: When using multiple RU enclosures to support more than one RF band, each RU is supporting a different frequency. When routing the coaxial antenna cable, it is critical that the appropriate frequency band cable be connected to the same frequency type RU. 1. Remove the dust cap from the DIN female connector located on the bottom of the enclosure. The port is labeled with “ANT”. 2.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-16. Junction Box AC Power Cable Routing 2. Secure the cable between the AC power port and the AC power junction box. Leave sufficient slack in the cable to allow it to be easily connected and disconnected from the AC power port. 3. Install any AC power supply wires that may be required between the AC junction box and the AC circuit breaker box. 4. At the AC circuit breaker box, connect the AC power supply load wire to the circuit breaker. 5.
mBSC-H DAS System Installation Manual Issue 7 Connect the other end of the RF cable to the port labeled “TX_IN” on the SLAVE Remote Unit User Interface as shown in Figure 4-17. Connect the second cable to the port labeled "RX_IN" on the MASTER RU. Connect the other end of the second RF cable to the port labeled "RX_OUT on the SLAVE RU. Figure 4-17.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-18.
mBSC-H DAS System Installation Manual Issue 7 4.2.6 Remote Unit Installation Review Use the following steps listed in Tables 4-3 and 4-4 to review the installation completion status 4.2.6.1 Mechanical Installation Review Items Table 4-4. Remote Unit Mechanical Installation Check Lists Description 1 Confirm that the Unit is mounted firmly and is stable. 2 Verify that the Unit is affixed per manufacturer's specifications.
mBSC-H DAS System Installation Manual Issue 7 4.2.
mBSC-H DAS System Installation Manual Issue 7 © 2009-2014, BTI Wireless Page 38
mBSC-H DAS System Installation Manual Issue 7 4.3 HOST UNIT INSTALLATION Danger: Wet conditions increase the potential for receiving an electrical shock when installing or using electrical power equipment. To avoid electrical shock, never install or use the electrical equipment in a wet location. Warning: Verify that the Unit has been ground with an earth-bonding cable to the grounding connector. 4.3.
mBSC-H DAS System Installation Manual Issue 7 Single Host Unit Hardware and Fasteners Customer Install POI INTERFACE CABLE 4 Factory Install Rec'd The following is a list of tools and any additional materials required for the Host Unit installation: Small Phillips screwdriver Wire cutters Wire Harness (Required for Expanded Third Party Alarm) 4.3.
mBSC-H DAS System Installation Manual Issue 7 NOTE: Check particularly for any damage to the fiber optic connectors on the FIU module. Check the power connectors located at the back of the Host Unit and check the back plane connectors located inside the Host Unit for any damage. . 4.3.4 Electrical Installation 4.3.4.1 Electrical Safety Precautions Please read the general Safety Precautions presented in Section 1.2 Safety Precautions 1.
mBSC-H DAS System Installation Manual Issue 7 4.3.4.2 Grounding The Unit must be grounded. The Host Unit is grounded during a factory installation in the optional cabinet with an earth-bonding cable connected to the provided grounding connection. Do not connect external devices to the grounding connection. Please verify the Unit is securely grounded. If it is no longer securely grounded, please use the following procedure to ground the Unit: Figure 4-20. Host Unit Grounding Connection 1.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-21. Grounded Host Unit (shown with optional POI Unit, also grounded) 4. Tighten the screw, making sure the cable is securely connected before moving to the next phase of the installation. 4.3.4.3 DC Power Cable Connection Danger: Please use caution when working with DC power. Ensure all power is disconnected before working on power circuit. Warning: Verify that the Unit has been ground with an earth-bonding cable to the grounding connector.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-22. Factory Installed DC Power Cable 1. Confirm electrical polarity of the power cables to match the customer provided DC power system. 2. Verify the DC power cable is attached securely, as shown Figure 4-22. 3. If the DC power cable is not secure, turn off all associated DC power to the Host Unit, and secure the power cables as shown. 4.3.4.4 Install the BIU and FIU modules Figure 4-23. BIU and FIU modules 1.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-24. Alarm Interface 1. With wire cutting tools, prepare the connecting wires. 2. Loosen the screws in each connector. 3. Use the Input Alarm configurations shown in Table 4-8 and the Output Alarm configurations in Table 4-9 to determine the wire placement. 4. Slide the bared wires into the slot under the screw and tighten securely. 5. Plug all the alarm connectors into the Alarm Input interface as shown in Figure 4-25 and Figure 4-26.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-25. Input Alarm Installation (Alarm On) Alarm Type Table 4-9. Output Alarm Configuration On Major COM1/NC1 COM1/NO1 Minor COM2/NC2 COM2/NO2 Off Figure 4-26. Output Alarm Installation (Alarm On) 4.3.4.6 Connect the BIU/FIU Modules Connect the BIU to the FIU-S with the provided interface cable using the following procedure: 1. Connect one end of the interface cable to the BIU port labeled "Tx1 Out". 2.
mBSC-H DAS System Installation Manual Issue 7 4. Connect the other end of the cable to the FIU port labeled "Rx1", Figure 4-27. Figure 4-27. Connect the BIU to the FIU For a two BIU and FIU-NS configuration, use the additional provided interface cables and the following procedure: 5. Connect the one end of the interface cable to the FIU-NS port labeled "Tx1". 6. Connect the end of the second interface cable to the FIU-NS port labeled "Tx2". 1.
mBSC-H DAS System Installation Manual Issue 7 4.3.4.8 Connect POI to BIU The Point of Interface (POI) is an optional component. The POI is connected to the BIU, Figure 4-29, using the following procedure: 1. Connect one end of a POI interface cable into the BIU port labeled "Tx1 In". 2. Connect the other end of the cable to the POI port labeled "Tx-L". 3. Connect the one end of a POI interface cable into the BIU port labeled "Rx4 Out". 4.
mBSC-H DAS System Installation Manual Issue 7 Items Table 4-10. Host Unit Electrical Installation Check List Description 1 Verify that the grounding cable is secure. 2 Confirm that the power cable connection is stable and is neither loose or damaged and that the electrical polarity is correct. 3 Verify that the fiber optic cable is securely connected. 4 Check that all installed cables are securely connected. 5 Confirm that the alarm connectors are securely connected.
mBSC-H DAS System Installation Manual Issue 7 4.3.
mBSC-H DAS System Installation Manual Issue 7 4.4 NMS INSTALLATION Caution: Network security may be compromised when accessing external Internet connectivity. The use of established security software is recommended. The NMS software is pre-installed on the Network Management Server and the NMS server arrives pre-installed in the optional Host Unit cabinet. This section provides instruction for installing the NMS software on a customer laptop or desktop and setting initial software parameters. Figure 4-31.
mBSC-H DAS System Installation Manual Issue 7 NMS ACCESSORY Quantity AC POWER CABLE 1 Received The following is a list of tools and any additional materials required for NMS software installation: Laptop, Desktop PC and/or Terminal Crossover Cable Hub and/or Router 4.4.3 Unpacking And Inspection This section provides the instructions for receiving the equipment shipment and verifying that no damage has occurred during shipping.
mBSC-H DAS System Installation Manual Issue 7 1. Connect the laptop, PC or terminal to the server through the hub using a crossover cable, Figure 4-33. The monitoring device may also be plugged directly into the server with a crossover cable. Figure 4-33. Connecting the Monitoring Device to the Server 2. Locate the NMS icon on the screen of the monitoring device, Figure 4-34. Figure 4-34. Locate NMS Icon 4.4.5 Initial System Setup 4.4.5.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-35. DAS Setup Wizard 4.4.5.2 Launch NMS 1. After copying the files, the Wizard will ask to launch NMS, Figure 4-36. 2. Select Yes. 3. The Wizard simultaneously places a shortcut on to the desktop of the computer as shown in Figure 4-37. Double clicking on the NMS icon on the desktop also launches the NMS Login screen. Figure 4-36.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-37. NMS Desktop Shortcut NOTE: Occasionally, there are compatibility problems that cause a configuration conflict when setting up the NMS. Follow the steps shown in the Troubleshooting Guide. If this does not resolve the issue, contact Customer Service (Section 6). 4. Verify that the Advance box is checked and then click in the password field, Figure 4-38. 5. Enter the following default password: 1 6. Click on OK.
mBSC-H DAS System Installation Manual Issue 7 following functions: Access and manage User Accounts and passwords (Add/Modify/Delete) Modify parameter defaults. Figure 4-39.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-40. User Account Icon 4.4.6.1 Modify Default Accounts The NMS User Manager comes with two default entries shown in the User list. For security reasons, changing the default manager account and password is highly recommended. The default User account may also be modified by overwriting the default information. The following procedure details the steps necessary to change the default accounts: 1.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-41. User Manager Screen 2. Select Manager in the User List, Figure 4-42 to see the default information.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-42. Manager Default Information 3. Delete the default entries, Figure 4-43 and enter the new user name and password. Note: There is a limit of 20 Alpha-Numeric characters for both User name and password entries. User names are selectable from the Login screen drop down menu, once entered into the system. Passwords are case sensitive.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-43. Edit Default Entries 4. Click Modify to update the User and Password. 5. Click Return to return to the NMS Command Console or continue to add or update User Accounts. 4.4.6.2 Set-up New User Accounts Adding a New User is easily managed through the User Manager screen. Access the User Manager screen, then use the following procedure to add Users of various levels: 1. Currently, there are two levels available for User Accounts.
mBSC-H DAS System Installation Manual Issue 7 Observer: This level is a monitoring functionality only. This level is most commonly used for users who will monitor the system and review alarm logs. At the Observer level, a user may only: modify their user name and password and; view, save and print Alarm information.Figure 4-44. Select a User Level 2. Enter a user name and password, Figure 4-45. Then click Add.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-45. Enter User name and Password Note: There is a limit of 20 Alpha-Numeric characters for both User name and password entries. User names are selectable from the Login screen drop down menu, once entered into the system. Passwords are case sensitive. 3. Additional detailed information for managing User accounts, including deleting and modifying User accounts is contained in the NMS User Manual. 4.4.6.
mBSC-H DAS System Installation Manual Issue 7 Figure 4-46. System Parameter Screen 4.4.7 Firmware Update DAS components periodically require firmware updates. The following list of components may require periodic firmware updates: BIU FIU PA RCU Remote Unit A notification email is sent with the firmware update attached as a file to the email. The following procedures detail the firmware update process: 1. Verify the email is genuine and the file attachment is safe for download.
mBSC-H DAS System Installation Manual Issue 7 3. Log into the NMS System. 4. Click on NetConfig 5. Using the RemoteSoftwareDownload interface, Figure 4-47, Locate the file by clicking on the browse button. Figure 4-47. Remote Software Download Screen 6. Click Start Download. The firmware update may be paused if needed by clicking the Pause button. 7. Once the download is complete, click Return. 4.4.8 Software Upgrade Installation 4.4.8.
mBSC-H DAS System Installation Manual Issue 7 5. Select Yes. Figure 4-48. Replace NMS File 1. An error dialog box will appear, Figure 4-49, if the older version of NMS is open and running. 2. Close NMS and click Try Again. Figure 4-49. NMS Update Fail Error Box 4.4.
mBSC-H DAS System Installation Manual Issue 7 Items Table 4-13. NMS Initial Installation Checklist Description 1 Verify that the CD is undamaged and the server software is installed. 2 Confirm that the version number once the set-up Wizard launches NMS. 3 Verify that the shortcut launches the NMS Login. 4 Check that the default Manager Account and password have been updated. 5 Confirm that new User accounts and passwords have been added. Items Table 4-14.
mBSC-H DAS System Installation Manual Issue 7 4.4.
mBSC-H DAS System Installation Manual Issue 7 5 mBSC DAS SYSTEM START-UP When the system component installations are complete, the system must be configured. Please refer to the applicable System Operation and User Manual for detailed system configurations, operations, and troubleshooting/test procedures 5.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-2. LAN Properties 4. Click on Internet Version Protocol (TCP/IPv4) and then click on Properties, Figure 5-3.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-3. Select Internet Protocol Version 4 5. Click on the second option, Use the Following IP Address:, Figure 5-4, and manually enter the IP Address: 128.0.2.30. The Subnet mask will automatically default to 255.255.0.0.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-4. Manually Enter the IP Address 6. Click OK. 5.2 INITIAL NETWORK CONFIGURATION Once installed and software configurations are complete, the network must be configured and activated. The first half of this section details the initial functions necessary for a basic system activation through the NMS. The second half details in-depth information for network system parameters.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-5. Accessing the Network Configuration screen The NMS software provides an example configuration as shown in Figures 5-5 and 5-6. The example may be deleted or the example information may be overwritten with customer specific information and then saved by clicking the Modify button. For the purposes of this installation manual, the example has been deleted to provide the most accurate details.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-6. BTI Example System Configuration 5.2.1 Add a Site The highest level of system configuration is defined by adding a Site Caption and a Site Code. The Site Caption alpha-numeric text field accepts any user-defined descriptive name (30 alpha-numeric character limit) and the Site Code accepts integer values only (1 through 9999 numeric limit). The following steps are used to add the Site Caption and Site Code: 1.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-7.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-8 Adding a Site 5.2.2 Add a Host Unit Once the Site Caption and Site Code have been configured, the Host Unit should be added to the system. The HU Caption alpha-numeric text field accepts any user-defined descriptive HU Caption (20 alpha-numeric character limit) and HU No. accepts integer values only (1 through 9999 numeric limit). The following steps provide the Host Unit configuration: 1.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-9. Adding a Host Unit 4. Verify that all changes have been correctly entered and click Add, Figure 5-10.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-10. Configured Host Unit 5.2.3 Configuring the Host Unit Hardware Card Once the Host Unit has been added to the system, the IP address for the Host Unit must be changed from the default to the designated network IP address in the Host Unit Hardware Card. Configuring the IP Address is done from the Main Command Screen. The following procedures outline the steps necessary to change the Host Unit IP Address: 1.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-11. Select the HU 4. Click on Parameter List. Then click Select All. 5. Click on Read, Figure 5-12.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-12. View the Current Values 6. Confirm Select All is unchecked. Click on Site IP Address in the Parameter List. 7. Click Edit. 8. Enter the new IP Address in the Edit Value Column, Figure 5-13. 9. Click Set, Figure 5-14.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-13.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-14. IP Address Update Setting 5.2.4 Map the IP Address to the NMS Software 1. Click the Netconfig button. 2. Select the Host Unit. Figure 5-15. 3. Change the IP Address(HU) from the default value to the designated network IP address. This will map the IP Address in the NMS System to the HU hardware card. 4. Then Click Modify. Click Return 5. Restart NMS to set the new parameters.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-15. Modify IP Address(HU) From the Main Command Screen: 1. Select the updated Host Unit. 2. Click on Parameter List. Then click Select All. 3. Click on Read, Figure 5-16. 4. Confirm that the HU Hardware Card IP Address matches.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-16. Confirm IP Address Update Accepted. 5.2.5 Adding a Master and/or a Slave Remote Unit Once the Site Caption, Site Code, and Host Unit have been configured, the Master Remote Unit should be added to the system first, followed by any Slave Remote Units. The RU Caption alpha-numeric text field accepts the default RU Caption or any user-defined descriptive RU Caption (20 alpha-numeric character limit) and the RU No.
mBSC-H DAS System Installation Manual Issue 7 3. Click on RU in the Select Equipment section. 4. Select the Slot No. for the Remote Unit. Use Table 6-1 as a guide for determining the Slot, Fiber and Type selections. 5. Select the Fiber value. 6. Select the Type of Remote Unit. Selecting the Type of Unit also designates the Master or Slave configuration. 7. NMS creates a default name based on the chosen slot, fiber and type values selected as shown in Illustration 6-13 and Illustration 6-14.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-18. Adding a Slave Remote Unit Name Table 5-2. Slots, Fiber and Type Values Configuration Value Slot Represents the slots on the HU from Left to Right that can be assigned to various equipment. Slots 1-6 are reserved for the FIU and BIU. Designating a slot number maps the RU to an FIU. Fiber Maps the RU to the Fiber connection on the Host Unit to the associated FIU. Type Defines the frequency used and must match the RU type installed.
mBSC-H DAS System Installation Manual Issue 7 5.2.6 Connect Host Unit to Server With the IP address updated, the Host Unit must be connected the server, Figure 5-19, for communication information to function. The Host Unit is connected from the Network port on the back interface through the hub to the server as shown in Figure 5-20 or may be directly connected from the back interface port to the server.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-21. Alarm Manager 5.3.2 Configuring Standard Alarm Defaults Configuring NMS is easily accomplished through the Custom Alarm tab, Figure 5-21. Select the alarm type and click the Select button for the appropriate category. Table 5-3 provides a recommended list of alarms by category that may be selected to create a custom alarm configuration.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-22. Configuring Custom Alarm Levels Figure 5-23 shows an active alarm.
mBSC-H DAS System Installation Manual Issue 7 Figure 5-23. Active Alarm Screen The Table5-3 provides alarm indicator descriptions for the mBSC DAS system. Alarm types for the Host Unit and Remote Unit monitored by the NMS are included as well as optional components such as the POI. The recommended category for the alarm indicator is included in column 3 of the table along with the affected component. Critical alarms indicate system failures that disable the uplink or downlink operation.
mBSC-H DAS System Installation Manual Issue 7 Alarm Indicator Downlink Function Alarm Downlink OverPower Downlink OverTemperature Downlink VSWR Fiber Light Rx Fiber Light Tx Fiber1 Light RX Fiber1 Light TX Fiber2 Light RX Fiber2 Light TX mRU and sRU1 comm mRU and sRU2 comm Uplink Alarm BIU No Communication FIU No Communication POI Fan1 POI Fan2 RCU +5V RCU +9V RCU No Communication RU Control Alarm RU Fan1 RU Fan2 Uplink Pilot Power Expanded Alarm Input 1 Expanded Alarm Input 2 Expanded Alarm Input 3 Expand
mBSC-H DAS System Installation Manual Issue 7 5.3.3 System Activation Review Table 5-4. System Start-up Review Items Description 1 Verify that the Host Unit communication was established. 2 Confirm that at least one Site has been added. 3 Verify that the Host Unit Hardware card IP address has been configured. 4 Check that the Remote Unit is communicating with the Host Unit 5 Confirm that the Host Unit is connected to the Server.
mBSC-H DAS System Installation Manual Issue 7 5.3.
mBSC-H DAS System Installation Manual Issue 7 6 Maintenance 6.1 GENERAL Please read the general Safety Precautions contained in Section 1.2 Safety Precautions The mBSC-H Fiber Distributed Antenna System (DAS) system has been designed to require minimal maintenance with component replacement as the primary method of maintenance. Care must be taken to prevent unintentional damage to any module seals.
mBSC-H DAS System Installation Manual Issue 7 component of the Host Unit requires replacement, care must be taken with modules so that seals are not damaged unintentionally as this may void warranty. Please see the Replacement Parts List for specific components available. 6.3 NMS The NMS may require periodic updates, both Firmware and Software. Please see Sections 4.4.7 Firmware Updates and 4.4.8 Software Upgrade Installation. 6.
mBSC-H DAS System Installation Manual Issue 7 7 CUSTOMER SERVICE CONTACT INFORMATION USA BTI Wireless 6185 Phyllis Dr. Unit D. Cypress, CA 90630, USA Tel: +1 714-230-8333 Fax: +1 714-230-8341 E-mail: Customer Service: CustomerService@bravotechinc.com Sales: sales@bravotechinc.com China BTI (Shenzhen) Co., Ltd. No.8 Building, Zone #3, Tangtou Industrial Park, Shiyan, Baoan District, Shenzhen, Guangdong P.R.China 518102 Tel: +86 755-2951-2233 Fax: +86 755-2951-2299 E-mail: chinasales@bravotechinc.