Form No.
High efficiency hot water and steam boilers for commercial and industrial applications Bryan flexible water tube boilers are ideally suited for both hot water and steam space heating systems as well as either high or low pressure process steam. In a range of sizes from 3,500,000 to 6,500,000 BTUH input, Bryan K series flexible tube boilers are ideal for many commercial, institutional and industrial applications.
Design and construction features that assure reliable performance A. Heavy steel boiler frame, built and stamped in accordance with the ASME boiler code. Hot water boilers constructed as standard for operating pressures to 160 psi. Also available for higher operating pressures. Steam boilers constructed as standard for operating pressures of 15 psi or 150 psi. Also available for higher operating pressures. Large steam release area for dry steam. B.
Bryan K Series Steam & Hot Water Boilers STEAM BOILER DIMENSIONS—inches (cm) BOILER MODEL K-350-S K-400-S K-450-S K-500-S K-550-S K-600-S K-650-S A Length Over Jacket 1071/4 (272.42) 117 (297.13) 1293/4 (329.57) 1421/2 (361.95) 1551/2 (394.97) 165 (419.10) 178 (452.12) B C D Flue Location Flue Size 541/8 (137.48) 59 (149.86) 653/8 (166.05) 713/4 (182.25) 781/4 (198.76) 83 (210.82) 891/2 (277.33) 20 (50.80) 24 (60.96) 24 (60.96) 24 (60.96) 24 (60.96) 24 (60.96) 24 (60.