Spec Sheet

800-558-17112 www.Broan-Nutone.com
Ventilation Options:
Open Hold Mode – Use this mode for
continuous fresh air ventilation. The damper will
be open and the dehumidifier fan will run to
introduce fresh air into the space at all times.
Closed Hold Mode – Use this mode when
no fresh air ventilation in required. The damper
will remain closed, but the dehumidifier fan will
still operate normally for air recirculation and
dehumidification.
Programmed Mode – Use this mode to
operate the motorized damper and the
dehumidifier fan according to the programmed
ventilation schedule to bring in fresh air.
DEH 3000 / 3000R
DEH 3000R Part Number: 4028407
Operating Voltage: 24 VAC
Max Current - DMP, COMP, FAN: 1 Amp each
Humidity Range / Accuracy: 10-95% RH, 5%
Auxillary Relay Capacity: 5 Amps, 24 VAC
Temp Range / Accuracy: 30°-90°F, 2°
Size: 4.95"L x 1.06"W x 4.19"H
Specifications:
DEH 3000 Part Number: 4028539
The DEH 3000 / 3000R Digital Control is designed to integrate with the Ultra line of whole house
ventilating dehumidifiers and enables homeowners to precisely monitor and control moisture levels,
manage fresh air ventilation (with optional damper) and activate air filtration – all from the convenience
of their living space.
+
_
+
_
Install controller up to
100' from dehumidifier.
Install sensor up to
100' from controller.
100'
100'
remote
sensor
4028407
Up to 200' Total
The DEH 3000R features a compact-sized remote sensor that
can be placed up to 100 feet away from the controller. The
remote sensor allows the homeowner to accurately control and
m
onitor the relative humidity in a given space without having to
locate the controller in the same area.
Only the DEH 3000 Offers All of
the Following Control Functions:
Central Fan Integration – Operates A/C fan
with dehumidifier operation.
A/C Sensor – Automatically activates or deactivates
the dehumidifier when the air conditioner runs.
High Temperature Cutout – Disables
dehumidifier operations if household
temperatures reach the cutout setpoint.
Dry Out Cycle Timer – Automatic fan cycling
to ensure dry and clean coils.
Auto Reboot – Resumes operation with prior
settings in the event of power failure.