Owner’s Manual Manuel de l'utilisateur Manual del Propietario Questions? Help is just a moment away! Vous avez des questions? Vous n'avez pas besoin d'aller loin pour trouver de l'aide! 030239 (2000W) Preguntas? La ayuda es justa un momento lejos! Call: Generator Helpline Appelez: Ligne d'assistance de Générateur Llame: Línea Directa del Generador 1-800-743-4115 M-F 8-5 CT web: www.briggsandstratton.
000W Generator TABLE OF CONTENTS SAFETY RULES Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-17 Storage . . . . . . . . . . . . . . .
2000W Generator WARNING DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid will cause severe chemical burns. Fuel and its vapors are extremely flammable and explosive.
2000W Generator CAUTION WARNING Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load. Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go. Broken bones, fractures, bruises or sprains could result. • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed. • DO NOT modify generator in any way.
2000W Generator KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Engine ON/OFF Switch Oil Fill/Drain Fuel Tank Fuel Shut-Off Valve Recoil Starter Choke Lever Circuit Breaker (AC) 120 Volt AC, 15 Amp Receptacle 12 Volt DC, 8.
2000W Generator ASSEMBLY Refer to Figure 1 and install the wheel kit as follows: 1. Tip generator up onto handle end. Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel. 2. Slide axle through both axle mounting brackets on cradle frame. 3. Slide a flat washer and wheel over the axle (Figure 1). If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115.
2000W Generator 1. Choose a viscosity according to the table below: WARNING 30 Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. 5W-30, 10W-30 Synthetic 5W-30, 10W-30 °F °C -20 -30 0 -20 20 -10 32 0 40 60 10 80 20 WHEN ADDING FUEL • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank. • Fill fuel tank outdoors. • DO NOT overfill tank.
2000W Generator USING THE GENERATOR Generator Location Generator Clearance System Ground WARNING The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is not connected to the AC neutral wire. If the generator is tested by a receptacle tester, it will not show the same ground circuit condition as for a home receptacle. Running generator gives off carbon monoxide, an odorless, colorless, poison gas.
2000W Generator OPERATING THE GENERATOR 4. Place the engine switch in the “On” position (Figure 7). Figure 7 — Engine Switch in On Position CAUTION Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it. • See “Don’t Overload Generator”. • Start generator and let engine stabilize before connecting electrical loads. • Connect electrical loads in OFF position, then turn ON for operation.
2000W Generator 6. Charging a Battery Slide the choke lever left to the “Run” position as the engine warms up. Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. DO NOT use the unit to charge any 6 Volt batteries. DO NOT use the unit to crank an engine having a discharged battery. NOTE: Under no load conditions, the engine speed may vary slightly faster or slower until engine temperatures stabilize.
2000W Generator 6. Connect battery charge cable clamp with black handle to battery post or terminal indicated by Negative, NEG, or (–) (Figure 8). 7. Start generator. Let the engine run while battery recharges. 8. When battery has charged, shut down engine (see “Stopping The Engine”) Figure 10 — 12 Volt DC Accessory Jack NOTE: Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer’s instructions carefully.
2000W Generator In an emergency, use the original shipping carton as a temporary shelter: For a more permanent shelter, build a structure that will enclose three sides and the top of the generator. 7. Cut off all carton flaps. 7. 8. Cut out one long side of carton to expose muffler side of unit as shown in Figure 11. Make sure entire muffler-side of generator is exposed, as shown in Figure 11. IMPORTANT: The generator must be at least 5 ft.
2000W Generator DON'T OVERLOAD GENERATOR 3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly. 4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above.
2000W Generator ENGINE TECHNICAL INFORMATION PRODUCT SPECIFICATIONS This is a single cylinder, overhead valve(OHV), air cooled engine. It is a low emissions engine. Generator Specifications Starting Wattage . . . . . . . . . . . . . . . . 3,000 Watts Wattage . . . . . . . . . . . . . . . . . . . . . . . 2,000 Watts Load Current At 120 Volts AC . . . . . . . . . . . . . .16.6 Amps At 12 Volts DC . . . . . . . . . . . . . . .8.3 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . .
2000W Generator GENERAL RECOMMENDATIONS GENERATOR MAINTENANCE Regular maintenance will improve the performance and extend the life of the generator. See any authorized Briggs and Stratton Power Products dealer for service. The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain generator as instructed in this manual.
2000W Generator • Use a damp cloth to wipe exterior surfaces clean. 3. CAUTION Clean area around oil drain plug (Figure 14). Figure 14 — Oil Drain Plug Improper treatment of generator can damage it and shorten its life. • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors. • DO NOT insert any objects through cooling slots. • • • Use a soft bristle brush to loosen caked on dirt, oil, etc. Use a vacuum cleaner to pick up loose dirt and debris.
2000W Generator 5. Check electrode gap with wire feeler gauge and set spark plug gap to 0.030 inch (0.76 mm) if necessary (Figure 15). Figure 16 – Service Spark Arrester Screen Spark Arrester Attachment Screw Figure 15 — Service Spark Plug Spark Arrester Screen 6. Reinstall spark plug. 7. Reconnect spark plug wire to spark plug. Muffler Tail Pipe 1. Loosen screw on muffler tail pipe and remove spark arrester screen.
2000W Generator STORAGE INSTRUCTIONS Change Oil While engine is still warm, drain oil from crankcase. Refill with recommended grade. The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Oil Cylinder Bore • Remove spark plug and pour about 1/2 ounce (15ml) of clean engine oil into the cylinder.
2000W Generator TROUBLESHOOTING Problem Engine is running, but no AC output is available. Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact Briggs and Stratton Power Products service facility. 3. Poor connection or defective cord set. 3. Check and repair. 4. Connected device is bad. 4. Connect another device that is in good condition. 1. Short circuit in a connected load. 1. Disconnect shorted electrical load.
00W Generator NOTES 20
2000W Generator NOTES 21
EMISSION CONTROL SYSTEM WARRANTY Mitsubishi Heavy Industries, LTD (MHI) and the California Air Resources Board (CARB) Emission Control System Warranty Statement (Owner's Defect Warranty Rights and Obligations) In the interest of the environment, MHI engines that meet strict emission requirements are labeled, “This ULGE conforms to 1995-1998 California Emission Control Regulations”.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004 LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser.