VIDEOJET multi 4000 VJM-4016 en Installation Manual
VIDEOJET multi 4000 Table of Contents | en 3 Table of contents 1 Safety 5 1.1 Electric shock hazard 5 1.2 Installation and operation 5 1.3 Maintenance and repair 6 2 Short information 7 2.1 About this manual 7 2.2 Conventions in this manual 7 2.3 Intended use 7 2.4 EU Directives 7 2.5 Rating plate 7 3 System overview 8 3.1 Parts included 8 3.2 System requirements 8 3.3 Overview of functions 3.4 Connections, controls and displays 11 3.4.1 Front view 11 3.4.
en | Table of Contents VIDEOJET multi 4000 10 Technical data 29 10.1 Electrical 29 10.2 Mechanical 29 10.3 Environmental conditions 29 10.4 Standards 29 2014.02 | V1 | F.01U.298.
VIDEOJET multi 4000 Safety | en 1 Safety 1.1 Electric shock hazard – 5 Never attempt to connect the unit to any power network other than the type for which it is intended. – Connect the unit to an earthed mains socket-outlet. – Never open the housing. – If a fault occurs, disconnect the unit from the power supply and from all other units. – Install the unit only in a dry, weather-protected location. – When installing in a switch cabinet, ensure that the unit has sufficient grounding.
en | Safety VIDEOJET multi 4000 – When making connections, use only the cables supplied or use appropriate cables immune to electromagnetic interference. – Position and run all cables so that they are protected from damage, and provide adequate cable strain relief where needed. – When installing in a switch cabinet, ensure that the screw joints are free of tension and subject to as little mechanical stress as possible. Ensure that the unit has sufficient grounding. 1.
VIDEOJET multi 4000 Short information | en 2 Short information 2.1 About this manual 7 This manual is intended for persons responsible for the installation and operation of the VIDEOJET multi 4000 encoder. International, national and any regional electrical engineering regulations must be followed at all times. Relevant knowledge of network technology is required. The manual describes the installation of the unit. Conventions in this manual 2.
en | System overview VIDEOJET multi 4000 3 System overview 3.1 Parts included – 1 VIDEOJET multi 4000 video encoder – 1 accessory bag – 1 Installation Manual – optional: 1 power cord (depending on the ordered product package) Notice! Check that the delivery is complete and in perfect condition. Arrange for the unit to be checked by Bosch Security Systems if you find any damage. 3.
System overview | en VIDEOJET multi 4000 9 Audio encoding The VIDEOJET multi 4000 encoder uses the G.711, AAC, and L16 audio compression standards. G.711 is the default setting for live transmission. For recording the default setting is AAC. When configuring with a Web browser, you can select your preferred standard for recording. Using video management systems, this is also true for live audio.
en | System overview VIDEOJET multi 4000 Summary The VIDEOJET multi 4000 encoder provides the following main functions: – Video, audio, and data transmission over IP data networks – Dual Streaming function for the encoder for simultaneous encoding with two individually – Multicast function for simultaneous image transmission to multiple receivers – 16 analog BNC composite video inputs (PAL/NTSC) – Video encoding according to international standard H.
VIDEOJET multi 4000 System overview | en 3.4 Connections, controls and displays 3.4.1 Front view 1 11 Factory reset button to restore factory default settings 2 LED ACTIVITY flashes during data transmission 3 LED LINK lights up when the unit is connected to the network 4 LED STATUS lights up during startup 5 LED CONNECT lights up when supplied with power after startup See also – LEDs, page 24 Bosch Sicherheitssysteme GmbH Installation Manual 2014.02 | V1 | F.01U.298.
en | System overview 3.4.2 VIDEOJET multi 4000 Rear view 1 VIDEO IN 1 to VIDEO IN 16 video inputs BNC socket for connecting the video source 2 ETH RJ45 socket for connecting to an Ethernet LAN (local network), 10/100/1000 MBit Base-T 3 AUDIO IN audio connection (mono) 3.5 mm (1/8 in) stereo socket audio in for connecting two audio sources 4 Terminal block for alarm inputs, relay output and serial interface 5 AUDIO OUT audio connection (mono) 3.
VIDEOJET multi 4000 Installation | en 4 Installation 4.1 Preparations 13 The VIDEOJET multi 4000 encoder is designed for installation in a switch cabinet. Mounting the unit in a 19-inch rack using the installation material supplied is a quick and easy operation. Please ensure the following installation conditions: – Do not install the unit close to heaters or other heat sources. Avoid locations exposed to direct sunlight. – Allow sufficient space for running cables.
en | Installation 2014.02 | V1 | F.01U.298.
VIDEOJET multi 4000 Connection | en 5 Connection 5.1 Connecting cameras 15 You can connect a maximum of 16 video sources to the VIDEOJET multi 4000 encoder. Any cameras and other video sources that produce a standard PAL or NTSC signal are suitable. 4 Connect each of the cameras or other video sources to BNC sockets VIDEO IN 1 to VIDEO IN 16 using a video cable (75 ohm, BNC plug). Note that termination is always on. Bosch Sicherheitssysteme GmbH Installation Manual 2014.02 | V1 | F.01U.298.
5.2 en | Connection VIDEOJET multi 4000 Establishing the network connection You can connect the unit to a 10/100/1000 Base-T network using a standard UTP category 5 cable with RJ45 plugs. 4 2014.02 | V1 | F.01U.298.750 Connect the unit to the network via the ETH socket.
VIDEOJET multi 4000 5.3 Connection | en 17 Connecting audio The unit has two audio ports for audio line signals. The audio signals are transmitted two-way and in sync with the video signals. The following specifications should be complied with in all cases. 2 × audio in: Impedance 9 kohm typ., 5.5 Vp-p max. input voltage; microphone amplifier 60 dB max. 1 × line out: 3.0 Vp-p typ.
5.4 en | Connection VIDEOJET multi 4000 Connecting alarm inputs and relay output Notice! For correct connection of alarm inputs and relay outputs, observe the labelling on the unit. Alarm inputs The unit has 4 alarm inputs on the terminal block. The alarm inputs are used to connect to external alarm devices such as door contacts or sensors. With the appropriate configuration, an alarm sensor can automatically connect the unit to a remote location, for example.
VIDEOJET multi 4000 Connection | en 2. 19 Connect the terminal block to the socket on the unit observing the labeling. See also – 5.5 Terminal block, page 25 Creating a serial connection Notice! For correct connection, observe the labelling on the unit. The bidirectional data interface is used to control units connected to the VIDEOJET multi 4000 encoder, such as a dome camera with a motorized lens. The connection supports the RS-232, RS-422, and RS-485 transmission standards.
5.6 en | Connection VIDEOJET multi 4000 Power on/power off Depending on the ordered product package, the unit is delivered together with a power cord. Notice! Use only a suitable power cord. Where necessary, use suitable facilities to ensure that the power supply is free of interference such as voltage surges, spikes or brownouts. Connect the unit to an earthed mains socket-outlet. Do not connect the unit to the power supply until all other connections have been made. 1.
VIDEOJET multi 4000 Configuration | en 6 Configuration 6.1 Setup 21 Before you can operate the unit within your network, it must have a valid IP address for your network and a compatible subnet mask. Note: As a default DHCP is enabled in the unit’s network settings. With an active DHCP server in the network you must know the IP address assigned by the DHCP server to operate the unit. The following default address is preset at the factory: 192.168.0.
en | Configuration VIDEOJET multi 4000 Additional parameters You can check and set additional parameters with the assistance of the Configuration Manager application in Video Client. You can find detailed information on this in the documentation for these applications. Note that the audio function is not activated by default. To use audio connections activate the corresponding setting when configuring the unit. 2014.02 | V1 | F.01U.298.
VIDEOJET multi 4000 Troubleshooting | en 7 Troubleshooting 7.1 Contact 23 If you are unable to resolve a malfunction, please contact your supplier or systems integrator, or go directly to Bosch Security Systems Customer Service. The following tables are intended to help you identify the causes of malfunctions and correct them where possible. 7.2 General malfunctions Malfunction Possible causes Recommended solution No image transmission Camera error.
en | Troubleshooting VIDEOJET multi 4000 Malfunction Possible causes Recommended solution Control of cameras or The cable connection between Check all cable connections other units is not the serial interface and the and ensure all plugs are possible. connected unit is not correct. properly fitted. The interface parameters do Make sure that the settings of not match those of the other all units involved are unit connected. compatible.
VIDEOJET multi 4000 Troubleshooting | en 25 STATUS LED Lights up: Startup in progress. Flashes: The unit is faulty, for example following failed firmware upload. CONNECT LED Lights up: The unit is switched on and startup completed. Flashes: Video connection active. RJ45 socket LEDs Left LED flashes (as ACTIVITY Traffic on the network. LED): Right LED lights up (as LINK Network connection established. LED): 7.
en | Troubleshooting VIDEOJET multi 4000 The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The mode used depends on the current configuration.
VIDEOJET multi 4000 Maintenance | en 8 Maintenance 8.1 Updates 27 Firmware updates are carried out via our Video Client software or other management systems in use. Please refer to the relevant documentation. 8.2 Factory reset You can use the factory reset button to restore the unit to its original settings. Any changes to the settings are overwritten by the factory defaults. A reset may be necessary, for example, if the unit has invalid settings that prevent it from functioning as desired. 1.
en | Decommissioning VIDEOJET multi 4000 9 Decommissioning 9.1 Transfer VIDEOJET multi 4000 should only be passed on together with this installation manual. 9.2 Disposal Your Bosch product is designed and manufactured with high-quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
VIDEOJET multi 4000 Technical data | en 10 Technical data 10.1 Electrical 10.2 Input voltage 100 to 240 V AC, 47 to 63 Hz Input current 0.32 to 0.15 A Power consumption 23 W max Connectors IEC 320 C14 29 Mechanical Dimensions (H × W ×D) 44 × 443 × 157 mm (1.732 × 17.441 × 6.181 in), without brackets including BNC sockets Weight Approx. 1.7 kg (3.7 lb) Video 16 × BNC socket, 75 ohm, terminated Analog composite, 0.7 to 1.2 Vp-p, NTSC or PAL Audio 2 × 3.
en | Technical data VIDEOJET multi 4000 Total delay 260 ms typical Dual Streaming Full performance and full frame rate on both streams for every video input channel Frame rate 1 to 25/30 ips (PAL/NTSC) Audio standards G.711, L16, AAC-LC Audio frequency rate G.711: 300 Hz to 3.4 kHz L16: 300 Hz to 6.4 kHz AAC-LC: 300 Hz to 6.4 kHz Audio sampling rate G.711: 8 kHz L16: 16 kHz AAC-LC: 16 kHz Audio data rate G.
VIDEOJET multi 4000 Index | en 31 Index A N Alarm, 12 Network, 16 Alarm input, 18 Network connection, 12, 20, 25 Audio connections, 12, 17 O C Operation, 5 Cameras, 15 Overview of functions, 8 Closing contact, 18 P Conventions, 7 D Parameters, 22 Pin assignment, 26 Danger, 5 Processor load, 25 Data interface, 19 Processor load indicator, 25 Default IP address, 21 Default IP address, 21 DHCP, 21 Dome camera, 19 Dual Streaming, 8 E R Rear panel connections, 12 Regulations, 7 Relay, 1
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.