BioEntry Plus ARD-FPBEPPR-OC | ARD-FPBEPHP-OC ARD-FPBEPIC-OC | ARD-FPBEPMF-OC en Installation manual
BioEntry Plus Table of Contents | en 3 Table of Contents 1 Safety precautions 5 2 Basics of fingerprint recognition 6 3 How to place a finger 7 4 Product Contents 9 5 Description 12 6 Product Dimension 15 7 Cables and Connectors 16 8 Installation of Wall-mount Bracket 18 9 Connections 19 9.1 Power Connection 19 9.2 Ethernet Connection 19 9.3 RS485 Connections 20 9.4 Relay Connection 22 9.5 Digital Input Connection 23 9.
en | Table of Contents BioEntry Plus 10 Network Default Setting 24 11 Installation References 25 12 Electrical Specification 27 13 Troubleshooting 28 14 Device Cleaning 29 15 FCC Rules 30 16 Specifications 31 Index 32 | V 1.1 | 2010.
BioEntry Plus 1 Safety precautions | en 5 Safety precautions The list below is to keep user’s safety and prevent any loss. NOTICE! Please read carefully before use. – Do not install the device in a place subject to direct sun – Do not place a magnet near the product. Magnetic objects light, humidity, dust or soot. such as magnet, CRT, TV, monitor or speaker may damage the device. – Do not place the device next to heating equipments.
2 en | Basics of fingerprint recognition BioEntry Plus Basics of fingerprint recognition What is fingerprint recognition? – Fingerprint is an individual’s own biometric information and does not change throughout his/her life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. – Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards.
BioEntry Plus 3 How to place a finger | en 7 How to place a finger Bosch fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal fingerprint recognition performance. Select a finger to enroll – It is recommended to use an index finger or a middle – Thumb, ring or little finger is relatively more difficult to finger.
en | How to place a finger BioEntry Plus Tips for different fingerprint conditions – Bosch fingerprint products are designed to scan fingerprint smoothly regardless of the conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please refer to the followings tips. – If a finger is stained with sweat or water, scan after – If a finger is covered with dust or impurities, scan – If a finger is way too dry, place after blowing warm wiping moisture off.
BioEntry Plus 4 Product Contents | en 9 Product Contents Basic Contents BioEntry Plus Bosch Access Systems GmbH Installation manual Wall-mounting metal bracket | V 1.1 | 2010.
en | Product Contents BioEntry Plus Wall mounting screws – 2 ea Star-shaped screws Star-shaped small wrench Software CD 3 pin, 4 pin, 5 pin, 7 pin cables - each 1 ea | V 1.1 | 2010.
BioEntry Plus Product Contents | en 11 Optional accessories Secure I/O 12V power adaptor Plastic stand USB fingerprint scanner for enrollment on PC Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
5 en | Description BioEntry Plus Description Front 1 RF card reading part Place an RF card over the picture. 2 LED Displays current status using seven different colors. 3 Fingerprint sensing part Place a finger on a sensor surface. LED Status per Color Color | V 1.1 | 2010.
BioEntry Plus Description | en Color Mode 13 Description blue/sky-blue alternating, 2 sec. normal red/pink alternating, 2 sec. locked blue/red alternating, 2 sec. Initialized time due to the internal battery discharge. blue/yellow alternating, 2 sec. DHCP fail red blinking, 2 sec. Failed. Please contact to your distributor or Bosch. yellow blinking, 2 sec. Waiting for input. yellow blinking, 1 sec. Receiving IP address from DHCP server.
en | Description BioEntry Plus Back 1 3 pin connector - wiegand input or ouput 2 5 pin connector - power and RS485 3 4 pin connector - ethernet (TCP/IP) 4 7 pin connector - digital input and relay output 5 DIP switch: RS485 termination setting - Section 9.3 RS485 Connections Network default setting Section 10 Network Default Setting | V 1.1 | 2010.
BioEntry Plus 6 Product Dimension | en 15 Product Dimension Front Side Metal bracket unit = mm Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
7 en | Cables and Connectors BioEntry Plus Cables and Connectors Power and RS485 Pin Pin description Wire 1 Power +12V red 2 Power GND black 3 RS485 GND gray 4 RS485 TRx+ blue 5 RS485 TRx- yellow Pin Pin description Wire 1 Tx+ yellow 6 2 Tx- green 3 3 Rx+ red 2 4 Rx- black 1 TCP/IP | V 1.1 | 2010.
BioEntry Plus Cables and Connectors | en 17 Wiegand In/output (Switchable) Pin Pin description Wire 1 Wiegand Data 0 green 2 Wiegand Data 1 white 3 Wiegand GND black Digital Inputs and Relay output Pin Pin description Wire 1 SW1 input yellow 2 SW1 GND black 3 SW2 input green 4 SW2 GND black 5 Relay normal close orange 6 Relay common blue 7 Relay normal open white Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
8 en | Installation of Wall-mount Bracket BioEntry Plus Installation of Wall-mount Bracket Step 1 Step 2 Step 3 Step description Step 1: Fix wall mount bracket on a wall using wall mounting screws (1). Step 2: Hook BioEntry Plus on the wall mount bracket. Step 3: Fix BioEntry Plus and wall mounting bracket using a star-shaped screw (2). | V 1.1 | 2010.
BioEntry Plus Connections | en 9 Connections 9.1 Power Connection 19 Recommended power supply – 12V ± 10%, at least 500mA. – Comply with standard IEC/EN 60950-1. – To share the power with other devices, use a power supply with higher current ratings. 9.2 Ethernet Connection Ethernet Connection via HUB Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
en | Connections BioEntry Plus Ethernet Connection directly with PC To connect BioEntry Plus with a PC directly, connect both devices with a straight CAT-5 cable. As the BioEntry Plus supports auto MDI/MDIX feature, it is not necessary to use a crossover type cable. 9.3 RS485 Connections RS485 Connection for Host Communication 1= Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter, refer to the converter’s manual. | V 1.1 | 2010.
BioEntry Plus Connections | en 21 NOTICE! – Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be necessary to lower the baudrates. – The GND signal may be omitted if and only if the GND potential difference is less than ± 5V. RS485 Connection for Secure I/O 1= Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter, refer to the converter’s manual.
en | Connections 9.4 BioEntry Plus Relay Connection Relay Connection – Fail safe lock Relay Connection – Fail secure lock Relay Connection - Automatic door | V 1.1 | 2010.
BioEntry Plus 9.5 Connections | en 23 Digital Input Connection Digital Input Connection - RTE, Door sensor Digital Input Connection - Alarm, Emergency sw 9.6 Wiegand I/O Connection Wiegand Input Wiegand Output Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
10 en | Network Default Setting BioEntry Plus Network Default Setting In case of forgetting network setting of BioEntry Plus (TCP/IP or RS-485 setting) during installation or using BioEntry Plus, user can initialize network setting (TCP/IP or RS-485 setting) by using DIP SW installed on the back panel of BioEntry Plus. Please refer to the figures in below. How to initialize Network Setting 1. Turn off BioEntry Plus power. 2. Please make DIP SW #2 ON (Please refer to figure1.) 3.
BioEntry Plus 11 Installation References | en 25 Installation References Installation Reference 1 - Stand alone 1= Power supply 2= Door lock 3= Exit button 4= Door sensor 5= PC with Bio application via LAN 6= Enroll scanner Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
en | Installation References BioEntry Plus Installation Reference 2 – Secure | V 1.1 | 2010.
BioEntry Plus 12 Electrical Specification | en 27 Electrical Specification Typ. Max. Notes 12 minimum: 10.8 Power Voltage (V) 13.2 Use regulated DC power adapter only. Current (mA) 250 Switch Input VIH (V) TBD VIL (V) TBD Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors. TTL/Wiegand Output VOH (V) 5 VOL (V) 0.8 Pull-up resistance (Ω) 4.7k The output ports are open drain type, pulled up with 4.7k resistors internally.
13 en | Troubleshooting BioEntry Plus Troubleshooting Fingerprint can not be read well or it takes too long. – Check whether a finger or fingerprint sensor is stained with sweat, water, or dust – Retry after wiping off finger and fingerprint sensor with dry towel. – If a fingerprint is way too dry, blow on the finger and retry. Fingerprint is entered but authorization keeps failing. – Check whether the user is restricted by door zone or time zone.
BioEntry Plus 14 Device Cleaning | en 29 Device Cleaning – Wipe out machine surface with dry towel or cloth. – In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with dry towel. – Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and fingerprint can’t be entered. Bosch Access Systems GmbH Installation manual | V 1.1 | 2010.
15 en | FCC Rules BioEntry Plus FCC Rules Caution – Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment. – RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE – DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Warning This device complies with part 15 of the FCC Rules.
BioEntry Plus 16 Specifications | en 31 Specifications Item Specification CPU 400 MHz DSP Fingerprint sensor 500 dpi optical/Capacitive sensor User capacity 5000 users (10,000 templates) Log capacity 50,000 events Matching speed Less than 1 second Operation mode Fingerprint RF Card RF Card + Fingerprint Network interface TCP/IP Internal relay Deadbolt, EM lock, door strike, automatic door TTL I/O 2 inputs for exit switch and door sensor Wiegand I/O 1 Port (Wiegand input or output is
en | Specifications | V 1.1 | 2010.
Bosch Access Systems GmbH Charlottenburger Allee 50 D-52068 Aachen Germany www.boschsecurity.