Specifications Sheet

21
PROFESSIONAL
246
341
62
14,5
25
73
37
491
509
15,5
24,5
370
133,5 255,5
540
BORA VENTILATION HANDBOOK
technical data
Supply voltage 220 – 240 V
Frequency 50/60 Hz
Maximum power consumption 5.0 kW
Maximum gas cooktop power 5.0 kW
Surface material SCHOTT CERAN
®
Dimensions (WxDxH) 370 x 540 x 73 mm
Power levels 1 – 9, P
Maximum power rating 20 W
Minimum fuse protection 1 x 0.5 A.
Weight (incl. accessories/packaging) 11.5 kg
Back cooking zone dimensions Ø 200 mm
Power supply cable 1.5 m (L, N, PE)
high-power burner 800–3000 W
normal burner 550–2000 W
Front cooking zone dimensions Ø 240 mm
pan support high-power burner 270 x 270 x 25/50 mm
pan support normal burner 235 x 235 x 25/50 mm
Product description
Intelligent control knob
Oversized 4 24 cooking surface
Variable heat retention function
Sunken gas burners
Automatic reignition
Dishwasher-safe pan supports
childproong feature
automatic heat up function
Demo mode
Modular system
Scope of delivery
Gas glass ceramic cooktop PKG11-100
2 x control knobs
2 x cast iron pan supports
Gas nozzle set G20/20 mbar natural gas
Flexible gas connection tube, length 500 mm, 1/2“ external thread
2 x connection cables for the control knobs
Connection cable to the extractor
operating and installation instructions
height adjustment plate set
mounting straps
Adapter cylindrical-conical
Seal
glass ceramic scraper
Accessories
Gas nozzle set G20 - 10 mbar natural gas PKGDS2010
Gas nozzle set G20 - 13 mbar natural gas PKGDS2013
Gas nozzle set G20 - 20 mbar natural gas PKGDS2020
Gas nozzle set G20 - 25 mbar natural gas PKGDS2025
Gas nozzle set G25 - 20 mbar natural gas PKGDS2520
Gas nozzle set G25 - 25 mbar or G25.3 - 25 mbar natural gas PKGDS2525
Gas nozzle set G30/G31 - 28-30 or 37 mbar liquid gas PKGDS3028
Gas nozzle set G30/G31 - 50 mbar liquid gas PKGDS3050
Gas nozzle set G31 - 30 mbar liquid gas PKGDS3130
Gas nozzle set G31 - 50 mbar liquid gas PKGDS3150
product- and planning instructions
Ensure su󹩴cient air supply below the gas cooktop.Either over the front of
the body (opening cross-section > 50 cm²) or over the plinth area (opening
cross-section > 150 cm²)
Provide a return ow aperture (opening cross-section > 1000 cm² per air
cleaning unit) for recirculation in the plinth area
Please note the local regulations and connection requirements applicable to
gas cooktops
Please note the special installation and processing guidelines for the gas
cooktop PKG11-100 (see operating and installation instructions)
When operating a gas cooktop with a cooktop extractor, the gas ame can
be affected (depending on the height of the power level on the cooktop
extractor)
PKG11
BORA Pro gas glass ceramic cooktop with 2 cooking zones
BORA PROFESSIONAL 2.0

Summary of content (1 pages)