EN BORA Classic 2.0 system installation instructions Cooktop extractor and cooktops C2XIMEN-006 www.bora.
EN Table of Contents 1 General information 3 1.3 1.4 1.5 Liability.............................................................................. 3 Validity of the operating and installation instructions....................................................................... 3 Product conformity.......................................................... 3 Data protection................................................................. 3 Presentation of information.......................................
General information 1 General information These instructions contain important information to protect you from injury and prevent damage to the appliance. Please read these instructions carefully before installing or using the appliance for the first time. Other documents apply alongside these instructions. Please by all means adhere to all documents that form part of the scope of delivery.
Safety EN 2 Safety The appliance complies with the stipulated safety requirements. The user is responsible for the safe use of the appliance, cleaning and maintenance. Improper use can lead to personal injury and damage to property. 2.1 Use as intended The appliance is solely intended for preparing food in private households.
Safety CAUTION! Risk of injury from heavy lifting If not handled correctly, carrying and installing appliances can cause injury to the limbs or torso. XX If necessary, carry and install the appliance with another person. XX Use appropriate aids to prevent damage or injury. CAUTION! Damage from improper use The appliance surfaces must not be used as work or storage surfaces. This can damage the appliances (particularly in the case of hard and sharp objects).
Safety EN ÿÿ WARNING! Risk of injury due to moving fan wheel There is a risk of injury while the fan is turning. XX Only install the device with the power disconnected. XX Connect both sides of the fan to the duct system before commissioning. Special safety instructions for the planning of extractor systems ÿÿ DANGER! Risk of smoke inhalation When the cooktop extractor is used in exhaust air mode, it draws in air from the room it is installed in and from neighbouring rooms.
Safety 2.4 Safety instructions – repairs, servicing and spare parts The appliance must only be repaired and ii serviced by trained specialists who are familiar with and comply with the standard national regulations and supplementary regulations of the local utility companies. Work on electrical components must only be ii conducted by trained electrical personnel. XX Before any repair work, safely disconnect the appliance from the mains supply.
Technical data 3 Technical data 3.1 CKA2/CKA2AB Cooktop extractor Power levels Connection on the exhaust side Tab. 3.1 Technical data CKA2/CKA2AB 7 80 41 Value 220 - 240 V 50/60 Hz max. 550 W 69 TR 3.15 A 439 x 515 x 190 mm 7.5 kg SSG glass/1.4301 stainless steel and plastic Fig. 3.2 90 Parameter Supply voltage Frequency Power consumption (including external BORA Universal article fans) Fuse protection (internal) Dimensions (width x depth x height) Weight (incl.
Technical data CKFI Value 220 - 240 V 50/60 Hz 3.68 kW 1 x 16 A 327 x 515 x 58 mm 27,5 327 230 48,5 1 - 9, P 3 230 x 230 mm 230 x 230 mm 230 x 230 mm 230 x 230 mm 230 x 460 mm 515 230 7.9 kg 2100 W 3680 W 2100 W 3680 W 182.8 (Wh/kg) 181.1 (Wh/kg) 207.0 (Wh/kg) 190.3 (Wh/kg) R3 Parameter Supply voltage Frequency Power consumption Fuse protection Dimensions (width x depth x height) Weight (incl.
Technical data CKI Value 220 - 240 V 50/60 Hz 3.68 kW 1 x 16 A 327 x 515 x 58 mm R3 327 1 - 9, P 3 Ø 230 mm Ø 165 mm Ø 230 mm Ø 165 mm 515 7.6 kg 2300 W 3680 W 1400 W 2200 W 180.5 (Wh/kg) 178.7 (Wh/kg) 179.6 (Wh/kg) Fig. 3.8 CKI device dimensions top view 58 7 Parameter Supply voltage Frequency Power consumption Fuse protection Dimensions (width x depth x height) Weight (incl.
Technical data CKIW Tab. 3.4 Technical data CKIW Value 220 - 240 V 50/60 Hz 3.0 kW 1 x 16 A 327 x 515 x 116 mm R3 327 9.8 kg 1 - 9, P 3 Ø 250 mm 515 Parameter Supply voltage Frequency Power consumption Fuse protection Dimensions (width x depth x height) Weight (incl. accessories/packaging) Cooktop Power levels Warming levels Cooking zone power setting Device dimensions CKIW Ø2 50 3.4 EN 2400 W 3000 W CKIW device dimensions top view 116 47 6 Fig. 3.11 Fig. 3.12 Fig. 3.13 www.bora.
Technical data CKCH Value 220 - 240 V 50/60 Hz 3.68 kW 1 x 16 A 327 x 515 x 75 mm R3 327 1-9, P, 2-ring additional switching 3 Ø 215 mm 2100 W 3000 W Ø 120 mm 600 W Ø 180 mm 1600 W Ø 215 mm 191.3 (Wh/kg) Ø 120/180 mm 197.6 (Wh/kg) 194.5 (Wh/kg) Fig. 3.14 515 7.2 kg CKCH device dimensions top view Fig. 3.15 Fig. 3.16 12 240 43,5 300 13,5 75 45 7 Parameter Supply voltage Frequency Power consumption Fuse protection Dimensions (width x depth x height) Weight (incl.
Technical data CKCB Value 220 - 240 V 50/60 Hz 3.68 kW 1 x 16 A 327 x 515 x 75 mm R3 140 1-9, 2-ring connection, roaster cooking zone connection 3 Ø 180 mm 1600 W Ø 120 mm 600 W Ø 180 mm 1600 W Ø 180 x 410 mm 3680 W Fig. 3.17 CKCB device dimensions top view Technical data CKCB Fig. 3.19 240 43,5 300 13,5 75 45 Fig. 3.18 www.bora.com 515 7.
Technical data 3.7 CKG Device dimensions CKG Parameter Value Supply voltage 220-240 V Frequency 50/60 Hz Total burner output 5.0 kW Power rating 20 W Fuse protection 1 x 0.5 A Dimensions (width x depth x height) 327 x 515 x 73 mm cooktop pan support high-power burner 270 x 270 x 25/50 mm pan support normal burner 235 x 235 x 25/50 mm Weight (incl. accessories/packaging) 11.
Technical data CKT Tab. 3.8 Value 220 - 240 V 50/60 Hz 3.5 kW 1 x 16 A 327 x 515 x 73 mm 327 37,5 250 38,5 13.6 kg 150 - 230 °C, 250 °C (1-9, P) 3 250 x 220 mm 1750 W 250 x 220 mm 1750 W 70 - 250 °C 515 Parameter Supply voltage Frequency Power consumption Fuse protection Dimensions (width x depth x height) Weight (incl.
Installation EN 4 Installation all safety and warning information (see the Safety chapter). XX Follow the enclosed manufacturer’s information. 4.1.1 Operating the cooktop extractor with a fireplace that depends on the air in the room 4.1 The state and regional laws and regulations must be ii observed with regard to the exhaust duct design.
Installation No window contact switches may be installed that ii separate the control unit from the power supply (phase separation). Only the Home In interface is to be used. 4.2 Checking the delivery XX Make sure the delivery is complete and check it for damage. there are any missing or damaged parts, please notify BORA After Sales Service. XX Do not under any circumstances install parts which are damaged.
Installation EN 4.4.3 Recirculation when using the cooktop extractor as a recirculation system 4.4.
Installation If the gas cooktop is used in a model with two cooktop ii extractors, it is to be installed at the side. If installed between the cooktop extractors, the pull of air on both sides may affect the flames. Air supply to gas cooktop CKG 1 2 4.5 EN Cut-out dimensions The minimum distance of 50 mm from the front edge of ii the worktop to the worktop cut-out is a recommendation from BORA. XX Comply with the instructions of the worktop manufacturer.
Installation EN 4.6 4.5.2 Surface mounting Minimum installation dimensions ≤ (≥ 50) B ±2 Installation dimensions R5 ≥800 ≥ 600 495 ±2 ≥600 ≥ 50 840 Fig. 4.9 Cut-out dimensions for surface mounting 10 10 - 40 Fig. 4.11 Fig. 4.10 Dimension of support for surface mounting Cooktops/cooktop extractor Tab. 4.4 1/1 B in mm 424 2/1 752 3/2 1197 4/2 1525 ≥720 ≥800 840 Cut-out dimensions of the appliance combinations in the case of surface mounting Fig. 4.
Einbauschnitte 389* BORA Classic 2.0 verbinder e 600): CKA2 mitmit Flachschalldämpfer USDF, Flachkanalverbinder CKA2 Flachschalldämpfer USDF, Flachkanalverbinder EFVEFV undund Übergangsstück Versatz EFRV110 (Zeile 600): Übergangsstück Versatz EFRV110 (Zeile 700): min.700* 600* min. 50 I �1 • • min. 50 'I �1 I ��- �r= I 0 0- ��- �r============,�====i 00 0- 0- 0 0- .. 0 0 0- a:, ss .e: .e: 00 00 • 860* (min. 720)* • 767 (min. 627) min. 50 '" 0 0- ======== ===,�====i . .
Installation EN 1 Fig. 4.16 Airflow towards the rear (right or left) Fig. 4.18 [1] [2] 2 Assembled cooktop extractor CKA2/CKA2AB Cooktop extractor CKA2/CKA2AB for airflow towards the right Cooktop extractor CKA2/CKA2AB for airflow towards the left If the adapter panel is fitted correctly, the duct ii connection will always be at the front on both models (facing the user).
Installation XX Insert the adapter panel [2] into the connection module [3] from above. XX To do this, slide the adapter panel into the slots on the connection module [3]. XX Do not use force to assemble the parts. XX Ensure that the lock clicks into place. EN Adjusting the installation height (only in the case of flush installation) Assemble the base module: XX Place the base module [1] on top of the connection module [3] with its adapter panel [2] already fitted.
Installation EN Example of a standard set-up Adapting the 90° bend: 2 1 1 2 3 4 3 5 Fig. 4.22 [1] [2] [3] Shortening the 90° bend 90° bend Cut marks Fine saw 6 XX Adapt the 90° bend [1] to the depth of the worktop if necessary by shortening it accordingly at the cut marks [2] using a fine saw [3]. 7 Fig. 4.
Installation 4.10.2 Installing the additional fan The maximum exhaust air duct length with a fan is 6 m. ii EN Adjusting the installation height (only in the case of flush installation) XX Install an additional fan in the exhaust duct if necessary. that a minimum clearance of 3 m is maintained between the fan units. XX Use only BORA Universal fans.
Installation EN 4.11.3 Securing the cooktops Cooktops CKFI, CKI, CKIW, CKCH, CKCB, CKG 1 XX Do not use a cordless screwdriver or similar electrical device to secure the Tepan stainless steel grill XX Check that the alignment and installation height are correct. 4.12 Connecting external switch contacts 2 The Home In and Home Out external connections must ii only be connected by a certified specialist. The specialist 3 also assumes responsibility for the proper installation and commissioning.
Installation Preparing the control unit 1 3 2 4 EN 5 1 9 25 2 5 3 37 45 Fig. 4.31 4 Fig. 4.
Installation EN 4.13 Establishing communication and power connection The cooktops of the BORA Classic 2.0 system can only be ii operated with the central operating unit of the cooktop extractor CKA2/CKA2AB. 1 The communication link between the cooktop extractor ii and cooktops is established via the control lines of the 2 central operating unit. The cooktops have their own electricity supply. This must ii be connected during installation. Fig. 4.
Installation 4.13.1 Establishing contact between the cooktop extractor and cooktops XX Only EN 4.13.3 Establishing contact between the operating unit and control unit use the cables supplied in the scope of delivery. 1 2 3 1 Fig. 4.38 Socket for the CAT 5e communication cable on the operating unit 1 5 Fig. 4.
Installation EN 4.13.5 Positioning the control unit ii Position the control unit inside the kitchen unit in such a ii way that it cannot be freely accessed by the user 1 The control unit must be placed inside the kitchen unit. (e.g. behind the plinth panel). Permitted positions inside the kitchen unit: OO loose on a false floor OO loose on the shallow duct OO mounted on the kitchen unit When positioning the control unit please observe the ii length of the mains cable (1 m). 4.13.
Installation The connection bracket and connection pieces must be equipped with a 1/2 inch external thread in accordance with the regulatory country requirements (see table 4.8). XX Connect the appliance as follows: XX Switch all appliances off. XX Close the gas supply. XX Switch off the main switch/automatic circuit breaker before connecting the cooktop. XX Secure the main switch/automatic circuit breaker against being switched back on without permission.
Installation EN Changing the gas burner nozzle in the gas burner 1 Fig. 4.43 [1] Connection to the test point adapter (LPG) Test point adapter XX Attach the test point adapter [1] to the gas cooktop connection. XX Ensure that the seal is positioned correctly. XX Tighten all connections so that they are secure. XX Check that installation has been done correctly. XX Check the correct functioning of the stopcock. XX Check the gas pressure (LPG) as follows: XX Set the control knob to the 0 position.
Installation Total nominal connection values for U-LPG/ 2.75 kPa test point pressure: 18.6 Mj/h Cooktop energy consumption AU/NZ – U-LPG/ 2.75 kPa test point pressure: High Power front burner 11.2 Mj/h Normal back burner 7.4 Mj/h Total nominal connection values for NG/ 1.0 kPa test point pressure: 19.5 Mj/h Cooktop energy consumption AU/NZ – NG/ 1.00 kPa test point pressure: High power front burner Normal back burner 12.0 Mj/h 7.
Installation EN 4.15 Initial operation 4.15.2 Function test Special requirements for the initial operation of the gas cooktop CKG: XX Carry Minimum requirement for operating the gas cooktop ii CKG: system software 03.00 (or higher) XX If necessary, query the installed software version (see the Menu section in the operating instructions). XX If necessary, update the system software (see the Menu section in the operating instructions). 4.15.
Installation EN 4.16 Sealing the devices 1 Fig. 4.47 [1] Silicone sealant for flush installation black, heat-resistant silicone sealant 1 Fig. 4.48 [1] Silicone sealant for surface mounting black, heat-resistant silicone sealant XX Once all of the installation work and initial operation is complete, seal the devices all around with black, heatresistant silicone sealant (also between the cooktop extractor and cooktop) [1]. XX Make sure that no silicone sealant gets under the cooktop. 4.
Decommissioning, d isassembly and disposal EN 5 Decommissioning, d isassembly and disposal XX Observe all safety and warning information (see the Safety section). XX Follow the enclosed manufacturer’s information. 5.1 Decommissioning Decommissioning is understood as final shutdown and disassembly. Following decommissioning, the device can either be installed into other units, sold on privately or disposed of.
Notes: 6 EN Notes: www.bora.
Notes: EN 38 www.bora.
Notes: www.bora.
Installation instructions: Original Translation Manufacturer: BORA Vertriebs GmbH & Co KG The distribution and duplication of this document, as well as the use and disclosure of its contents are prohibited unless expressly authorised. These operating and installation instructions have been drawn up with the greatest of care. But it cannot be ruled out that subsequent technical modifications have not yet been incorporated or the relevant content has not yet been adapted.