OPERATING INSTRUCTIONS GMS810-/GMS811-FIDOR Hydrocarbon Analyzer (FID) for Continuous Flue Gas Monitoring Installation Operation Maintenance
Document Information Document ID Title: Part No.: Version: Release: Warning Symbols Operating Instructions GMS810-/GMS811-FIDOR 8013911 1-0 2014-02 Hazard (general) Hazard by voltage Described Product Product name: GMS810-/GMS811-FIDOR Hazard by explosive substances/mixtures Manufacturer SICK AG Erwin-Sick-Str. 1 Phone: Fax: E-mail: · 79183 Waldkirch · Germany +49 7641 469-0 +49 7641 469-1149 info.pa@sick.
Information Symbols Important technical information for this device Important information on electrical or electronic functions Supplementary information Link to information at another place Nice to know GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 3
Contents 4 Contents 1 Important Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.1 Main hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.2 1.2.1 1.2.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Purpose of the device . . . . . . . . . . . . . . . . . .
Contents 4 Start-up 4.1 4.1.1 4.1.2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.2 Start up the FIDOR . . . . . . . .
Contents 6 9 Technical Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 9.1 9.1.1 9.1.2 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Electrical protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Information GMS810-/GMS811-FIDOR 1 Important Information Subject to change without notice Main hazards Main operating information Intended use Own responsibility GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 7
Important Information 1. 1 Main hazards Overview of important safety information: WARNING: Hazards by explosive or combustible gases. Do not use the FIDOR for measuring explosive or combustible gases. WARNING: Risk of explosions due to leaky lines The FID is supplied with hydrogen. Risk of explosions due to leaky lines. Do not cover the enclosure cover. Do not operate the FIDOR in closed rooms OR install a hydrogen sensor (H2 sensor) (< 25% LEL) 1. 2 Intended use 1.2.
Important Information 1.3 Responsibility of user Intended users The FIDOR may only be operated by qualified persons who, based on their device-specific training and knowledge as well as knowledge of the relevant regulations, can assess the tasks given and recognize the hazards involved. Correct use Use the FIDOR only as described in these Operating Instructions. The manufacturer bears no responsibility for any other use. Carry out the specified maintenance work.
Subject to change without notice Important Information 10 GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG
Product Description GMS810-/GMS811-FIDOR 2 Product Description Subject to change without notice Device features Functional principle Device description GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 11
Product Description 2. 1 Product identification Product name: Manufacturer: ● ● GMS810-/GMS811-FIDOR SICK AG Poppenbütteler Bogen 9b, 22399 Hamburg, Germany GMS810-FIDOR: FIDOR in 19“ enclosure with integrated operator panel (BCU). GMS811-FIDOR: FIDOR in 19“ enclosure and external operator panel (BCU). Type plate The type plate is located at the rear of the housing. 2.
Product Description 2.2.1 Method of operation The FIDOR operates independently. ● Automatic ignition of the flame and regulation of the operating pressures. ● Automatic start-up. ● The FIDOR signals an uncertain operational states with status indicators. The FIDOR remains in Measuring mode. ● Should a malfunction occur, the FIDOR switches automatically to “Failure”. The heated line and the sample gas path in the FIDOR are automatically purged with instrument air in this state.
Product Description 2.2.3 Measuring principle Fig. 2 Measuring principle Combustion air (Instrument air) Sample gas ● ● ● ● ● The FIDOR uses a flame ionization detector (FID) for measuring the hydrocarbons. A hydrogen flame supplied by fuel gas and combustion air burns in the FID. The sample gas is routed into this flame. The hydrocarbons contained in the sample gas are split; the produced hydrocarbon fragments are ionized.
Product Description 2.3 Interfaces The following interfaces are available for the FIDOR: ● Ethernet ● CAN Option: RS485/422 (Modbus RTU) via the CAN bus plug ● Analog and digital interfaces (depending on version). The analog and digital interfaces are part of the GMS800 I/O module. The GMS800 I/O module can be optionally installed in the rear cover of the 19"enclosure or be connected externally using the CAN bus.
Product Description 2. 5 SOPAS ET (PC program) Additionally, SOPAS ET can be used to set FIDOR parameters. SOPAS ET runs on an external PC connected via the Ethernet interface to the FIDOR.
Product Description Gas flow plan Fig. 3 Gas flow plan Subject to change without notice 2.
Product Description 2. 7 Information on operating gases This Section contains general information on operating gases. Quality of operating gases p. 74, »Gas supply« 2.7.1 Instrument air The instrument air is used as: ● Induction air for the ejector. ● Control air for pressure control. ● Combustion air for the FID (for the “internal catalyst” option). 2.7.2 Combustion air Instrument air (for measuring range > 500 mgC/m3). ● Internal catalyst (option) (for measuring range <= 500 mgC/m3).
Product Description 2.8 Sample gas NOTICE: Risk of corrosion The sample gas must not corrode the internal gas path. 2.8.1 Heated line NOTICE: Risk of condensation No condensation should occur in the heated line. Condensation can corrupt the measurement result and the condensate can obstruct the heated line and the gas filter. Prevent thermal bridges when connecting the heated line and the sample gas probe.
Subject to change without notice Product Description 20 GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG
Installation and Connection GMS810-/GMS811-FIDOR 3 Installation and Connection Subject to change without notice Installation Assembly GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 21
Installation and Connection 3. 1 Scope of delivery Please see the delivery documents for the scope of delivery. 3. 2 Installing WARNING: Risk of explosions due to leaky lines The FID is supplied with hydrogen. Risk of explosions due to leaky lines. Do not cover the enclosure cover.
Installation and Connection 3.4 Preparing the gas connections WARNING: Hazards through leaky gas path ● Health risk when noxious sample gas leaks out. ● Risk of damage to the FIDOR and adjacent equipment if the sample gas is corrosive or could create corrosive liquids in combination with water (e.g. humidity). ● The measured values could possibly be wrong if the gas path is leaky.
Installation and Connection 3.4.1 Connecting the instrument air Connect the instrument air supply to the FIDOR. 3.4.2 Connecting the combustion air Connect the combustion air if an external combustion air supply is used 3.4.3 Connecting the fuel gas (hydrogen) Recommendation: – Fit a pressure monitor on the fuel gas cylinder which monitors the cylinder pressure and emits a signal at a certain residual pressure (e.g. 10 bar).
Installation and Connection 3.4.5 Connecting the sample gas If the sample gas pressure is more than 150 hPa (mbar) higher than the ambient pressure: Install a bypass line (e.g. T-form screw connection) from which the FIDOR can draw the sample gas. If the sample gas contains large quantities of dust: Install an external dust filter in the sample gas supply line (preliminary filter, coarse filter). 1 Lay the heated line from the sampling probe to the FIDOR. 2 Screw on the heated line.
Installation and Connection 3. 5 Electrical installation WARNING: Health risk by voltage The preparation of the FIDOR may only be performed by skilled electricians who, based on their technical training and knowledge as well as knowledge of the relevant regulations, can assess the tasks given and recognize the hazards involved. The wiring system to the power source of the system must be installed and fused according to the relevant regulations. Fig.
Installation and Connection Signal connections 3.6 More information Operating Instructions “GMS800 IO Module”.
Installation and Connection 11 (–) Analog output 4 12 (+) analog output 4 (0/2/4 … 20 mA) 28 Name Significance Explanation DO5 N3M04DO01 (DO04) Measuring Measured value OK DO6 N3M04DO02 (DO04) Adjustment Adjustment running DO7 N3M04DO03 (DO04) Maintenance mode Maintenance mode active DO8 N3M04DO04 (DO04) Measuring range ID AO3 Identification of active measuring range from analog output AO3 GND AI1 N3M07AI01 (AI02) Reserved Not used AI2 N3M07AI02 (AI02) Reserved Not used AO1 N3M05AO01 (AO
Installation and Connection 3.7 CAN bus The remote control used is set at the factory depending on the order. To exchange the remote control: Please contact SICK Customer Service. More information Technical Information “FIDOR”. FIDOR can be connected with a CAN bus to SICK devices (SCU, BCU, I/O modules). If no device is connected to the CAN bus socket of the FIDOR: Connect the attached terminating resistor to the CAN bus socket. 3.
Subject to change without notice Installation and Connection 30 GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG
Start-up GMS810-/GMS811-FIDOR 4 Start-up Subject to change without notice Start-up Assessment of error-free function GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 31
Start-up 4. 1 Preparation 4.1.1 Check Check with a leak detector: Are the external hydrogen supply and the hydrogen connection gas-tight? After a longer period of standstill (several weeks), also check: Instrument air supply and fuel gas supply available and clean? Gas pressures. Sample gas outlet free from any blockages? Sampling probe ready for operation? 4.1.2 Procedure 1 Start the peripheral devices (e.g. heated line, sampling probe, catalyst).
Operation GMS810-/GMS811-FIDOR 5 Operation Subject to change without notice Controls Status signals Menu structure Menus GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 33
Operation 5. 1 Controls and indicators/displays Fig. 6 Operating and display elements (exemplary display) Status bar FIDOR:MEASURING Main menu 1 2 3 8 “POWER” LED .1 POWER Language User level BCU FIDOR .\ Back Current menu with menu level (numeric) FAILURE Classification LEDs ( p. 34, §5.1.1 ) MAINTENANCE REQUEST Enter Current menu tree Contrast setting (button) MEAS button Menu-specific buttons Status, LEDs.
Operation 5.1.2 Assignment of buttons Button Significance button Returns to the Measuring display from any menu (except “Diagnostic”). – All inputs not completed with are discarded. – If the FIDOR is set to “Maintenance”: Pressing the button does not affect the “Maintenance” state. If the MEAS button is pressed for more than 2 seconds: A menu for contrast setting is shown Menu-specific buttons
Operation 5. 2 Menu tree 5.2.1 Main menu More information on the operating philosophy of the Basic Control Unit (BCU) Operating Instructions “GMS800 BCU”. Several analyzers can be connected to the control unit. To go to the menu for the FIDOR: 1 Press . The Measuring display is displayed as a “List”. THC 9.38 mgC Menu Update interval: Approx. every second. 2 Press . 3 Select “FIDOR”.
Operation 5.2.1.1 Language .1 Language English Deutsch 1 Select the required language. 2 Close with .\ Save Back 5.2.1.2 User level Menus which allow changes to the measurement sequence are protected with a password. .2 User level 1 Auth. operator 2 Service 3 Log off 1 Select the required level. 2 Close with A password prompt is shown. .\ Enter Back Entering the password .2.2 Auth. operator 1 Enter the password. 2 Close with XXXX Subject to change without notice .
Operation 5.2.2 FIDOR menus Depending on operating state and user level not all menu items are displayed. 38 Menu tree Explanation Measured value Bar graph Line recorder Diagnostic Operating mode Measuring Uncertain Check Maintenance mode Process Subprocess Maint.req signals Maint. request Failure signals Failure Low temp.detected Logbook Counters Hardware pA-amplifier Digital input Digital output Temperature Pressure Voltage Current Power Telediagnostic Maint.
Subject to change without notice Operation Measuring point Name Gas timing Sample gas Zero gas Average ZG Ref.gas Average RG Purge time Application area Adjustment Adjustment results Act. Zero ZDrift abs. ZDrift rel. Act. Ref. RDrift abs. RDrift rel. Last Zero ZDrift abs. ZDrift rel. Last Ref. RDrift abs. RDrift rel. Zero + reference Start adj. Process M. value Zero Start adj. Process M. value Reference Start adj. Process M. value Abort adjustment Abort adj. Process M.
Operation p. 52, §5.2.8.3 p. 52, §5.2.8.4 p. 52, §5.2.8.5 p. 53, §5.2.9 p. 53, §5.2.9.1 p. 53, §5.2.9.2 p. 54, §5.2.9.3 Subject to change without notice Test gas (only in maintenance mode) Zero gas Reference gas Test gas off Standby (only in maintenance mode) Set standby Exit standby Configurations Save user setup Load user setup Load factory setup Factory setting Device information Serial number Location ID Version SOPAS FW Options Line voltage Power Not used Int.ready Ext.ready E.
Operation 5.2.3 Measuring display Menu: FIDOR/Measuring List (default) THC 9.38 mgC Bar graph Line recorder FIDOR:MEASURING FIDOR:MEASURING Hg 0 - 10 µg/m3 9,38 THC % 0 mg 15 100 1 50 60 Menu 5.2.4 Menu t Menu “List” measuring display Display of measured values in tabular form. The “List” measuring display is shown: ● Automatically after the start of the system. ● When the button is pressed. Update interval: Approx. every second.
Operation 5.2.5 Diagnostic Menu: FIDOR/Diagnostic This menu shows the operating mode. FIDOR:MEASURING Diagnostic 1 2 3 4 5 .4.2 p. 42, §5.2.5.1 p. 43, §5.2.5.2 p. 43, §5.2.5.3 p. 43, §5.2.5.4 p. 44, §5.2.5.5 Operating mode Logbook Counters Hardware Telediagnostic .\FIDOR Back 5.2.5.1 Enter Operating mode Menu: FIDOR/Diagnostic/Operating mode This menu shows the operating mode. Significance Yes = measurement in progress. No = no measurement.
Operation 5.2.5.2 Logbook Menu: FIDOR/Diagnostic/Logbook FIDOR:MEASURING Logbook .4.2.2.1 1/3 09-01-01 08:25 The currently existing messages are shown in this menu (Logbook SOPAS ET). ● ● Failure On #1: Pressure ● Current message / number of existing messages Date of occurrence (yy-mm-dd). Time of occurrence (hh:mm). Error message (error number and plain text). (List of messages p. 66, §8.6). .\FIDOR/Diagnostic/Logbook Back 5.2.5.
Operation Menu item Temperature Pressure Voltage Current Power Telediagnostic Menu: FIDOR/Diagnostic/Telediagnostic This menu shows an internal diagnosis (for service purposes). Menu item Maintenance request Failures Monitoring Start state Maint.req.
Operation 5.2.6 Parameter Menu: FIDOR/Parameter FIDOR:MEASURING Parameter 1 2 3 4 5 6 7 8 .4.3 p. 45, §5.2.6.1 p. 45, §5.2.6.2 p. 46, §5.2.6.3 p. 46, §5.2.6.4 p. 46, §5.2.6.5 p. 46, §5.2.6.6 p. 47, §5.2.6.7 p. 47, §5.2.6.8 Meas. display End value Reference gas Sample gas Sample gas spec. Measuring point Gas timing Application area .\FIDOR Back 5.2.6.1 Measured values Menu: FIDOR/Parameter/Meas. display Menu item Decimal places 5.2.6.
Operation 5.2.6.3 Reference gas Menu: FIDOR/Parameter/Reference gas This menu is used to define the reference gas. Menu item Value Unit Ref.gas 5.2.6.4 Sample gas Menu: FIDOR/Parameter/Sample gas Menu item Sample gas user defined 5.2.6.5 Significance Name of sample gas (propane, methane, ethane, user defined). Enter with <>, . Sample gas spec. Menu: FIDOR/Parameter/Sample gas spec. If the settings are to be changed: “Sample gas user defined” must be selected in menu FIDOR/Parameter/Sample gas.
Operation 5.2.6.7 Gas timing Menu: FIDOR/Parameter/Gas timing Menu item Sample gas Zero gas Average ZG Ref.gas Average RG Purge time 5.2.6.8 Significance Purge time [s] with sample gas after adjustment completion until the measured value is released again. Enter with , <>, <>, . Purge time [s] with zero gas after activation of zero gas during adjustment. The averaging time then starts. Enter with , <>, <>, .
Operation 5.2.7 Adjustment Menu: FIDOR/Adjustment FIDOR:MEASURING Adjustment 1 2 3 4 5 6 7 8 3 Adjustment results Zero + reference Zero Reference Abort adjustment Adjustment time Restart cycle Drift reset p. 48, §5.2.7.1 p. 48, §5.2.7.2 p. 49, §5.2.7.3 p. 49, §5.2.7.4 p. 49, §5.2.7.5 p. 49, §5.2.7.6 p. 49, §5.2.7.7 p. 50, §5.2.7.8 .\FIDOR Back Adjustment results Menu: FIDOR/Adjustment/Adjustment results This menu shows the adjustment results. Menu item Act. Zero ZDrift abs.
Operation 5.2.7.3 Zero point Menu: FIDOR/Adjustment/Zero Start an automatic zero point adjustment. Menu item Start adj. Process M. value 5.2.7.4 Significance Start zero point adjustment with . Actual device process (e.g. “ADJUSTMENT”). Actual measured value. Reference point Menu: FIDOR/Adjustment/Reference. Start an automatic reference point adjustment. Menu item Start adj. Process M. value 5.2.7.5 Abort adjustment Menu: FIDOR/Adjustment/Abort adjustment Abort adjustment Menu item Abort adj.
Operation 5.2.7.8 Drift reset Menu: FIDOR/Adjustment/Drift reset. This menu resets the drift. Significance Reset the relative drift. 1 Select “Drift reset”. 2 Confirm with .
Operation 5.2.8 Maintenance Menu: FIDOR/Maintenance FIDOR:MEASURING Maintenance .4.5 1 Ignition p. 51, §5.2.8.1 2 Maintenance mode p. 51, §5.2.8.2 3 Test gas p. 52, §5.2.8.3 (only in Maintenance mode) 4 Standby p. 52, §5.2.8.4 (only in Maintenance mode) 5 Configurations p. 52, §5.2.8.5 .\FIDOR Back 5.2.8.1 Enter Ignition Menu: FIDOR/Maintenance/Ignition The FID ignites automatically during start-up. This menu serves to start ignition manually.
Operation Test gas Menu: FIDOR/Maintenance/Test gas Zero and reference gas can be activated in this menu. An adjustment is not performed. Menu item Zero gas Reference gas Test gas off 5.2.8.4 Process M.value M.value Test gas off Process M.value M.value Significance Select the desired state and confirm with . Configurations Menu: FIDOR/Maintenance/Configurations This menu is used to save and load the configuration. Menu item Save user setup Load user setup Load factory setup 52 Process M.
Operation 5.2.9 Factory setting Menu: FIDOR/Factory setting FIDOR:MEASURING Factory setting .4.6 1 Device information p. 53, §5.2.9.1 7 Options p. 53, §5.2.9.2 8 Heated line p. 54, §5.2.9.3 .\FIDOR Back 5.2.9.1 Device information Menu: FIDOR/Factory setting/Device information This menu contains general device information. Menu item Serial number Location ID Version SOPAS FW 5.2.9.2 Significance Serial number. Name of measuring location. Internal identification number. Version number.
Operation 5.2.9.3 Heated line Menu: FIDOR/Factory setting/Heated line Significance Yes: Start automatic determination of heating control parameters. Input of nominal value of the temperature of the heated line [°C]. Enter with , <>, <>, .
Operation 5.3 Starting important operating sequences 5.3.1 Check and adjustment with test gas Step 1 2 3 4 Reference p. 23, §3.4 p. 51, §5.2.8.2 p. 46, §5.2.6.3 p. 47, §5.2.6.7 p. 48, §5.2.7.2 Subject to change without notice 5 Action Connect zero and reference gas. Switch device to “Maintenance”: Menu Maintenance/Maintenance mode/Maintenance mode. Set reference gas parameters: Menu Parameter/Reference gas. If necessary, set gas timing parameters: Menu Parameter/Gas timing.
Subject to change without notice Operation 56 GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG
Shutdown GMS810-/GMS811-FIDOR 6 Shutdown Subject to change without notice Switching the FIDOR off Shutting the FIDOR down Transport Disposal GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 57
Shutdown 6. 1 Preparations for shutdown Purge the sample gas path with a dry neutral gas. 6. 2 Shutdown procedure 1 Close off the test gas supply. 2 Close off the fuel gas supply. – The flame goes out. FIDOR (and sample gas sampling, if applicable) are automatically purged with zero gas. 3 Purge for a minimum of 10 minutes. 4 Interrupt sample gas sampling. 5 Close off the instrument air supply. 6 Shut off the zero gas supply (if installed). 7 Switch the FIDOR off 6.
Scheduled Maintenance GMS810-/GMS811-FIDOR 7 Scheduled Maintenance Subject to change without notice Maintenance plan GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 59
Scheduled Maintenance 7. 1 Maintenance intervals 7.1.1 Maintenance by the user Maintenance intervals depend on the individual application. Maintenance work Reference W Q1 H1 Y1 Check measured values for plausibility Visual inspection Perform adjustment[2] Check exhaust gas line[3] Replace sample gas filter as required --- p. 60, §7.3.1 p. 55, §5.3.1 --- p. 61, §7.3.3 x x x x x x x [1] x x x x [1]W = weekly Q = quarterly, H = half-yearly, Y = yearly. [2]Have performed by skilled persons.
Scheduled Maintenance 7.3.3 Replacing the sample gas filter NOTICE: Perform work on the sample gas filter only when it is cold. 7.3.3.1 Remove the sample gas filter 1 Unscrew 2 screws of the insulating cover. 2 Remove insulating cover and protection against bends. 3 Unscrew 4 screws of the sample gas inlet block. 4 Remove sample gas inlet block. 5 Remove O-ring and filter from sample gas inlet block. 7.3.3.2 Install the sample gas filter 1 Place filter into sample gas inlet block.
Subject to change without notice Scheduled Maintenance 62 GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG
Clearing Malfunctions GMS810-/GMS811-FIDOR 8 Clearing Malfunctions Subject to change without notice Fuses Status messages Implausible measuring results FID does not ignite GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 63
Clearing Malfunctions 8. 1 Necessary technical knowledge for repairs WARNING: Risk of explosions Only technicians with special FIDOR training are allowed to perform maintenance tasks on the FIDOR. Use original SICK spare parts only. 8. 2 Replacement of fuses CAUTION: Hazards caused by electric voltages Only let the work described in the following be carried out by skilled electricians who are familiar with potential risks and are able to avoid them. Disconnect the device from the mains.
Clearing Malfunctions 8.4 Failure Should a malfunction occur, the FIDOR switches automatically to “Failure”. In this state: ● The red status indicator lights. ● A status signal is set. ● The sample gas path (including sampling probe) is purged with zero gas. ● A relevant error message is displayed on the operator panel and entered in the logbook. If you cannot clear the error: Contact SICK Customer Service.
Clearing Malfunctions Error messages Message Failure I2C Press.module Software Watchdog Setup Start timeout Flame Zero point Ref. point Heating Catalyst Suction voltage 66 Possible cause Possible clearance Pressure control communi- Switch device off/on. cation error. Software error / program- Switch device off/on. ming error. Load user setup. Load factory setup. Internal fault. Switch device off/on. Check options. Load user setup. Load factory setup. Parameter settings are Switch device off/on.
Clearing Malfunctions Message Pressure EEPROM Possible clearance Check utility gases. Check utility gas lines. Check pressures. Remove heated line/sample gas sampling and check function. Check/replace sample gas filter. Switch device off/on. Check quality of zero gas, fuel gas and combustion air. Switch test gas and check displayed values. Perform adjustment. Check parameter settings. Load user setup. Load factory setup. Heated line Heating fault of heated line. Check options.
Clearing Malfunctions Message Heating Possible cause Heating warning of analyzer heating or of heated measurement amplifier. Catalyst Heating warning of integrated catalyst. Suction voltage warning. Working pressures cannot be regulated. Sample gas flow too low / too high. Process pressure out of specification. Sample gas filter blocked. Pressure control incorrect. Digital input: External main- Check options whether function is desired. tenance request signal Check initiator of external signal.
Technical Documentation GMS810-/GMS811-FIDOR 9 Technical Documentation Subject to change without notice Dimensions Technical Data GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 69
Technical Documentation 9. 1 Approvals 9.1.1 Conformity The technical design of this device complies with the following EU directives and EN standards: ● EU Directive NSP 2006/95/EC ● EU Directive EMC 2004/108/EC Applied EN standards: ● EN 61010-1, Safety requirements for electrical equipment for measurement, control and laboratory use ● EN 61326, Electrical equipment for measurement, control and laboratory use - EMC requirements 9.1.
Technical Documentation 9.2 Heated line Fig. 10 Line Fig. 11 Connection Pin 1 2 3 4 5 6 PE Assignment Heating Heating Pt100 monitoring Pt100 monitoring Pt100 control Pt100 control Protective conductor The pin numbers can be found on the plug. Subject to change without notice Description The heated line has a PTFE or stainless steel core with an outer diameter of 6 mm and an inner diameter of 4 mm. The PTFE core is either fitted securely with stainless steel armoring or is replaceable.
Technical Documentation Dimensions 9. 3 483 (19) X4 X7 X5 101.5 (4) X3 37,75 (1.5) 177 (7) 465 (18.3) 29 29 29 29 29 (1.14) (1.14) (1.14) (1.14) (1.14) 221 (8.7) 145 (5.7) 72 120 (4.7) 42 (1.65) Subject to change without notice 348 (13.7) 444 (17.
Technical Documentation 9.4 Technical data End range set delivered system documentation. Measured values[1] Measuring principle Measuring component Concentration unit Smallest measuring range Largest measuring range Tested measuring range[2] Flame ionization detector Total hydrocarbon (CnHm) mg org. C/m3, mg/m3, ppm, ppm C1, ppm C3, % by volume % LEL, % TLV 0 .. 15 mg org. C/m3, 0 .. 100 000 mg org. C/m3, 0 .. 15 mg C/m3 0 .. 50 mg C/m3 0 .. 150 mg C/m3 0 ..
Technical Documentation Ambient conditions Ambient temperature +5 … +40 °C (40 ... 104 °F) Storage temperature –20 … +70 °C (0 ... 160 °F) Relative humidity Max. 95% (without condensation) Ambient air pressure: 900 … 1100 hPa (mbar)[1] Degree of protection IP 40, for indoor use Allowable contamination: Degree of contamination 2 [1]If the pressure is different: Consult SICK Customer Service and perform a pressure adaption, if required.
I nd e x Keywords A Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assignment of buttons . . . . . . . . . . . . . . . . . . . . . . . C CAN bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Check (status) . . . . . . . . . .
In dex U Uncertain - Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Z Zero (menu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Zero gas (menu) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I nd e x GMS810-/GMS811-FIDOR · Operating Instructions · 8013911 V 1-0 · © SICK AG 77
8013911/2014-02/V1-0/ISubject to change without notice Australia Phone +61 3 9457 0600 1800 334 802 – tollfree E-Mail sales@sick.com.au Belgium/Luxembourg Phone +32 (0)2 466 55 66 E-Mail info@sick.be Brasil Phone +55 11 3215-4900 E-Mail sac@sick.com.br Canada Phone +1 905 771 14 44 E-Mail information@sick.com Česká Republika Phone +420 2 57 91 18 50 E-Mail sick@sick.cz China Phone +86 4000 121 000 E-Mail info.china@sick.net.cn Phone +852-2153 6300 E-Mail ghk@sick.com.