BodyMedia FIT Armband BW Manual BodyMedia, Inc. One Gateway Center 420 Fort Duquesne Blvd. Suite 1900 Pittsburgh, PA 15222 USA Armband Model AB185 www.bodymedia.com 100706_REV2 © Copyright 2010 BodyMedia, Inc.
Table of Contents Purpose of the System........................................................... 3 Setup Instructions.................................................................. 4 Armband Operating Instructions.......................................... 4 Proper Wear and Cleaning.............................................. 4 Removing the Armband strap from the Armband......... 6 Armband Status Indicators............................................. 6 Bluetooth® Wireless Technology Instructions.....
Purpose of the System Intended Use The system records and analyzes physiological parameters, and uses algorithms to report daily movement, calories burned, degree of physical activity, and steps taken. These objective health metrics facilitate maintenance of a healthy weight and an active lifestyle, and in conjunction with a balanced diet can result in a favorable influence on overall health.
Setup Instructions Please refer to the Quick Start included in the package for instructions on how to begin using the system. It only takes a few minutes to get set up and moving toward a healthier lifestyle. 4. Wear the Armband no more than 23 hours a day. Be sure to leave it off 1 hour per day. 5. Replace the strap if it has lost its elasticity. Information on obtaining replacement parts can be found in the Quick Start.
Removing the Armband strap from the Armband You will need to remove the Armband from its strap to upload data or to clean the Armband. 1. With the Armband logo facing upward, apply continuous downward pressure to the right side of the Armband until it separates from the Armband strap. • Green (solid) = More than 24 hours of battery life remain. • Amber (flashing) = Less than 24 hours of battery life remain. • Red (flashing) = Battery needs to be charged immediately and the Armband cannot collect data.
Bluetooth® Wireless Technology Instructions Pairing the Armband with a Smartphone The Armband is connected to a Smartphone with Bluetooth wireless technology using a procedure called ‘pairing.’ By following a few simple steps, your Armband can be paired with a Smartphone in a matter of minutes. 1. Put the Armband in pairing mode Once you have set up the Armband according to the Quick Start, you can pair it with a Smartphone.
Care Instructions Symbol Definitions To ensure the Armband is working correctly, they should be cleaned regularly. Clean the Armband daily after sweating or when it becomes noticeably moist or dirty. Failure to keep the Armband clean, or improper cleaning, may irritate the skin and affect the sensor performance. Do not use solvents, cleaners or other chemicals to clean the Armband and do not sterilize any part. Avoid the use of chemicals and lotions on the skin where the Armband is worn.
Cautions CAUTION: Always consult a physician before starting any new diet or exercise program. This system is not to be used for diagnostic purposes and is not intended to be a substitute for the medical advice or supervision of your personal physician. CAUTION: Materials in the Armband have been evaluated for skin contact. Because everyone’s skin is different you may experience irritation or redness after wearing the Armband. If this occurs, discontinue use and consult your physician.
Safe Disposal CAUTION: DO NOT IMMERSE THE ARMBAND IN WATER. The Armband is not designed to be used underwater or to come in continuous contact with water. CAUTION: Though the Armband was designed for wearability and long-term use, it is a sensitive monitoring device. Rough handling can break internal components. Never drop or shock the Armband and always store it in a safe place when not in use.
Troubleshooting Accuracy For troubleshooting information and additional resources, please refer to the Help section on www.bodymedia.com. Accelerometer (3-axis) Calibrated range is +/- 1.0g Product Specifications A minimum resolution of 0.05ºC Two-standard-deviation error of +/-0.08g on all axes Two standard deviation error of +/0.8°C A minimum resolution of 1.
Warranty Unless otherwise set forth in a separate limited warranty description included with the BodyMedia Hardware (including Armband, Display with Clip and Watch strap), BodyMedia warrants that BodyMedia Hardware is free of defects in materials and workmanship under normal use and service (“Limited Warranty”) for 1 year from the date the product is purchased by the original retail purchaser (the “Limited Warranty Period”).
User Environment Guidance and Manufacturer’s Declaration - Immunity 2.5m 1.5m 1.5m 1.5m Computer and Wireless Communicator Diagram not to scale. Guidance and Manufacturer’s Declaration - Emissions The Armband is intended for use in the electromagnetic environment specified below. The customer or user of the Armband should ensure that it is used in such an environment.
Guidance and Manufacturer’s Declaration - Emissions Recommended Separation Distances for the Product The Armband is intended for use in the electromagnetic environment specified below. The customer or user of the Armband should ensure that it is used in such an environment. The Armband is intended for use in the electromagnetic environment specified below.
Regulatory Statement FCC Declaration of Conformity – We, BodyMedia, Inc., One Gateway Center, 420 Fort Duquesne Boulevard, Suite 1900, Pittsburgh, PA 15222, declare under our sole responsibility that the products, BodyMedia, Inc. and BodyMedia® Armband (Model AB185) comply with part 15 of the FCC rules.
Copyright, Patent and Trademark Notice The products and services which include the software, firmware, algorithms, processes, and methods of BodyMedia FIT™, SenseWear® applications as well, all devices and components used therewith including the Armband, Display, and Wireless Communicator, are covered by one or more of the following patents: United States Patent Nos.: D439,981, 6,527,711, 6,595,929, 6,605,038, 7,020,508, 7,153,262, 7,261,690, 7,285,090 and 7,502,643; European Patent Nos.