Installation Sheet

INSTALLATION INSTRUCTIONS
BOBRICK MODEL B-4998 AND B-4998.99 WALL MOUNTED SWING-UP GRAB BARS
© 2016 by Bobrick Washroom Equipment, Inc.
Form No. 4998-69 r1/13/2016 Printed in U.S.A.
In the U.S.A.: BOBRICK WASHROOM EQUIPMENT, INC.
200 Commerce Drive, Clifton Park, New York 12065-1350 • Tel: (518) 877-7444 • FAX: 518-877-5029
6901 Tujunga Ave, North Hollywood, California 91605-6213 • Tel: (818) 982-9600 • FAX: 818-503-1102
or email: customerservice@bobrick.com
In Canada: BOBRICK WASHROOM EQUIPMENT COMPANY
45 Rolark Drive, Scarborough, Ontario M1R 3B1 • FAX: (877) 423-8555
Important Notes: Mounting Height and Wall Preparation
The mounting height shown in these instructions is based on American National Standard Institute Specication (ANSI A117.1-1980) and is provided
only as a guide. Check local building codes for grab bar mounting height to make sure installation complies with local code requirement.
Grab Bars are no stronger than the anchors or walls to which they are attached. They must be securely mounted to sustain a load of 500 lbs at any
point. Studs are to be reinforced and adequate backing must be mounted to the studs before the nished wall surface is applied to provide secure
attachment of the grab bar to the wall. The installation must comply with local building code requirements.
ALTERNATE METHODS OF INSTALLATION
Installation with Bobrick Mounting Kit Available as an Accessory
1. Reinforce wall studs prior to attachment of Bobrick anchor plate.
2. Fasten steel anchor plate to studs making sure it is plumb and square. Mount top of anchor plate 35'' (889mm) above nished oor. This will
locate the centerline of the top bar in the horizontal position at 33'' (838mm) above nished oor.
3. Mounting screws should be temporarily screwed into anchor plate at points marked by an S before application of nished wall surface, so that
the location of the mounting screw holes can be found for mounting the grab bar to the wall.
4. Apply nished wall surface to wall.
5. Remove mounting screws from wall. Mount grab bar, making sure screws are tight.
6. Test grab bar making certain it remains in both the vertical storage position and the horizontal use position.
Installation with Backing Furnished by Installer
1. Make certain backing meets local codes.
2. Reinforce wall studs prior to attachment of adequate backing.
3. Install adequate backing in wall at locations indicated in Figure 1. Allow for either #14 size screws, or in the case of steel backing 1/4-20
stainless steel screws of adequate length (neither are furnished by Bobrick). The steel backing must have a minimum thickness of 3/16''
(5mm) and screw holes be drilled and tapped.
4. Use grab bar back plate as a template to mark mounting screw hole locations.
5. After mounting grab bar make certain it remains in both the vertical storage position and the horizontal use position.
Installation to Solid Masonry Walls
1. Use inserts (lead shields or equivalent) for #14 screws (not furnished by Bobrick) and mount at height indicated in Figure 1 or per local code,
using grab bar back plate as template to mark mounting screw hole location.
2. After mounting grab bar, make certain it remains in both vertical storage position and the horizontal use position.
6-1/8''
155mm
S
S
1/2''
13mm
5-1/8''
130mm
8-3/4''
220mm
7-3/4''
195mm
S
S
1/2''
13mm
Mounting
Holes (4)
Bumper
8-3/4''
220mm
Finish Face of Wall
Stud
61''
1550mm
33''
840mm
29''
735mm
Provide
Adequate
Backing
S
S
34''
865mm
From Top
Mounting
Screws
Grab Bar Backplate
Finish Face of Floor
Figure 1 Figure 2