INSTALLATION and USE & CARE WALL HOODS PL, PY, IN, PM, HA, BZ, MH, WR, SC 197299 Version D
Please take a few moments now to fill in the information below for your future reference. In the event you require parts or service, this information will be needed to ensure you receive the highest quality service we can provide.
Table of Contents INSTALLATION INSTRUCTIONS: 5 Handling and Unpacking 7 Installation of Ducting & Electrical Specifications 8 Removing Liner from Shell | Mounting Shell to Wall 9 Installing In-Hood Blowers 10 Installing Remote Blowers 12 Installing In-Line Blowers 14 Installing Wall Hood Duct Covers 16 Installing Manhattan Series Ventilation Hoods USE AND CARE INSTRUCTIONS: 17 Operating the Push Button Controls 18 Cleaning Instructions
INSTALLATION INSTRUCTIONS IMPORTANT 1. This appliance was designed for ease of installation and operation. However, we recommend that you read all sections of this manual before you begin installation. 2. Do not remove permanently affixed labels, warnings or data plates from your appliance. This may void the manufacturer’s warranty and/or hinder effective servicing and maintenance. These instructions are to remain with the appliance and the consumer is to retain them for future reference. 3.
INSTALLATION INSTRUCTIONS WARNING To reduce the risk of cooking appliance grease fire: • Never leave the appliance unattended during use. Boil overs may occur causing spills which may ignite. • It is recommended you purchase a multi-purpose dry chemical or foam type fire extinguisher for your home and store it in close proximity to your appliances. • If a fire should occur do not turn on hood to evacuate smoke. Turn off hood. IMPORTANT This product is for general residential ventilation applications.
INSTALLATION INSTRUCTIONS Unpacking: • Check the package for damage. If any damage is visible you should mark the bill of lading you sign that there may be concealed damage. • Ensure the container is upright. If the container is not upright major damage can occur to your appliance. If damage is discovered do not refuse delivery Contact the dealer and file appropriate freight claims. Save all packaging material.
INSTALLATION INSTRUCTIONS Installation of Ducting for Proper Operation: IMPORTANT Proper installation of ducting is extremely important for optimal performance of your ventilation system. It is a basic requirement that the kitchen is provided with an air intake to ensure good air circulation and therefore proper operation of the hood. Without this incoming air a depression could form that would reduce the efficiency of the ventilation system. All CFMS are based on tests at 0.1 static pressure.
INSTALLATION INSTRUCTIONS Step 2: Remove ventilation hood liner from outer shell. (Figures A through F) A. B. C. D. Figure A: Figure B: Figure C: Figure D: Remove Baffle Filters Remove Grease Trough Remove Inner Shield Remove Control Panel Pull filters towards you to Turn fastening screw(s) ¼ Remove screws (front and Remove screws (front and disengage from liner. turn to unlock. back) attaching shield to back) attaching panel to ventilation hood liner. ventilation hood liner.
INSTALLATION INSTRUCTIONS Step 4-1: Installing In-hood 600 CFM Blowers Duct Connection Detail: 6” Round Recommended Duct Size: 6” | Minimum Duct Size: 6” Figure A: Figure B: Figure C: Figure D: Attach Blower Connect Plate Internally Connect Plate Externally Connect Power Supply Unscrew blower plate and Re-install all mounting Re-install all mounting Connect molex connector set to top or rear discharge. screws inside of liner. screws outside of liner. from control box to blower.
INSTALLATION INSTRUCTIONS Step 4-3. Installing Remote Blowers MODEL NUMBER: HYEX-1.0/HY-EX-1.4 MAXIMUM CFM: 1000 CFM/1400 CFM VOLTS/HERTZ/AMPS: 115VAC, 60 Hz, 2.9A (HYEX-1.0) and 3.3A (HYEX-1.4) REQUIRED DUCT SIZE: HYEX-1.0: 8” Round (51 sq. in. equiv.) / HYEX-1.4: 10” Round (80 sq. in. equiv.) FLAT OR LOW SLOPE ROOF IMPORTANT: Remove foam block from inside housing before operating 1. For flat roofs or roofs having pitch less than 1 ½” rise in 12”, mount blower on roof curb.
INSTALLATION INSTRUCTIONS Step 4-3. Installing Remote Blowers ELECTRICAL CONNECTIONS Figure 3 WARNING: TURN OFF POWER AT THE SERVICE BOX PRIOR TO WIRING BLOWER 1. Power supply for the blower s 115V AC, 60 Hz. See page 2 for specifications 2. Run electrical cable between the blower and the range hood or blower and wall switch. See Figure 3 3. Remove top enclosure of the blower for access to the wiring terminal block. 4. Push the electrical cable up through the bottom knock out of the blower body.
INSTALLATION INSTRUCTIONS Step 4-4. Installing In-line Blowers Mounting Option 1: Please follow all applicable codes when installing this unit 1. Equipment should be hung at its proper elevation by using temporary fixtures that can be removed after vibration hangers are installed. 2. Hanger may be fastened directly to the structure or somewhere between suspended unit (be sure not to over tighten the neoprene element. 3. Install hangers. 4.
INSTALLATION INSTRUCTIONS Step 4-4. Installing In-line Blowers Duct Detail: ATEX-0.8 – 8” Round ATEX-1.2 – 10” Round Dimensions and Wiring: Model A C D E Weight ATEX-0.8 8 12 ½ 15 ½ 7 19 lbs ATEX-1.2 10 14 15 8 21 lbs Step 5. Mount Outer Shell to Wall 1. The bottom of the hood should be 30” minimum to 36” maximum above the countertop for efficient operation. 2. This hood is designed to be plugged into a 3-prong Non-GFCI outlet – 120Volt, 10 amp.
INSTALLATION INSTRUCTIONS: 1-PIECE DUCT COVERS Step 8-1. Installing 1-Piece Duct Cover Option 1 1. Secure duct cover to top of hood using machine screws provided. 2. Mount complete unit to wall using instructions in Step 4 for Mounting Outer Shell to Wall. 3. Install blower plate into hood sealing connection with duct work. 4. Install blowers into hood. Step 8-2. Installing 1-Piece Duct Cover Option 2 1. Mount unit to wall using instructions in Step 4 for Mounting Outer Shell to Wall 2.
INSTALLATION INSTRUCTIONS: TELESCOPIC DUCT COVERS Step 8.3 Installing Telescopic Duct Cover Option 1 Mounting Bracket 1. Attach mounting bracket to wall 1/8” from ceiling and centered with hood. 2. Attach lower portion of duct cover to hood with hardware Upper Duct Optional Mounting Hole Location provided. 3. Slide upper portion into lower portion of duct cover. 4. Anchor and level hood assembly to wall at desired mounting height. Lower Duct 5.
INSTALLATION INSTRUCTIONS Manhattan Style Wall Hoods 1. Follow Step 2 of installation instructions on removing liner from outer shell. 2. Mount duct to ceiling using method below that best applies to your application. 3. Mount blower(s) into duct cover using hardware provided. 4. Anchor outer shell to wall and level. 5. Secure outer shell to duct cover using method below that best applies to your application. 6.
USE & CARE INSTRUCTIONS Section 1: Control Panel A B C D E Blower Controls Timer F Light Controls Blower Controls: Additional Controls: A – Blower starts on 1st speed E – Timer B – 2nd speed Pressing button during operation will cause C – 3rd speed blower to run for 5 minutes at its current speed. D – 4th speed (Boost Function)* Blower will automatically shut off.
USE & CARE INSTRUCTIONS Section 3: Baffle Filters IMPORTANT The function of the baffle filters is the absorption of grease particles that form during cooking. Do not operate ventilation hood without filters in hood. Baffle filters should be examined periodically to assure that the surfaces and parts are clean. 3.1: Removing Baffle Filters: • Hold both handles located on the filter. • Pull towards front of hood to depress spring system. • Pull back of filter down and away from hood. Image 3.2 3.
USE & CARE INSTRUCTIONS WARNING Make sure that the electrical power is off before cleaning. The recommended detergent is a solution of water and a neutral liquid soap. It is very important for the liquid soap to not contain granules that could scratch the surface. First apply the solution to a soft cloth and then rub the cloth over the hood. It is important to follow the direction of the metal grain with the cloth. Do not pour any liquid directly on the ventilation hood.