CERTIFIED FINAL DOCUMENT FLEX-PRO R Peristaltic Metering Pump Exclusive: TF D system SERIES A2V Operating Manual Tube Failure Detection Patented ProSeries 2 TWO-YEAR WARRANTY ProSeries TMR by Blue-White Ind. 5300 Business Drive, Huntington Beach, CA 92649 USA Phone: 714-893-8529 FAX: 714-894-9492 E mail: sales@blue-white.com | techsupport@blue-white.com Protected by Patents: 8,418,364; 8,215,931; 7,001,153; 7,284,964; 4,496,295 and other patents pending URL: www.Blue-White.
Page 2 Flex-Pro TABLE OF CONTENTS Section Heading 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Available Models . . . . . . . . . . . . . . . . . . . . . . . 2.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Materials of Construction . . . . . . . . . . . . . . . . . 3.0 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Agency Listings . . . . . . . . . . . . . . . . . . . . . . . . 4.0 Installation. . . . . . . . .
Page 3 Flex-Pro 1.0 Introduction Congratulations on purchasing Flex-Pro variable speed Peristaltic Metering Pump. A peristaltic pump is a type of positive displacement pump used for pumping a variety of fluids. Your Flex-Pro pump is pre-configured for tubing that shipped with your metering pump. Tubing assembly has an Identification number printed on tube for easy re-order; such as ND, NH, etc. Please Note: Your new pump has been pressure tested at factory with clean water before shipping.
Page 4 2.0 Flex-Pro Specifications Maximum working pressure (excluding pump tubes): 125 psig (8.6 bar) Note: see individual pump tube assembly maximum pressure ratings. Maximum Fluid temperature (excluding pump tubes): 3/8” OD x 1/4” ID tubing connections: 130o F (54o C) M/NPT connections: 185o F (85o C) Note: see individual pump tube assembly maximum temperature ratings. Maximum fluid viscosity: 12,000 Centipoise 30 ft. Water, 0 psig (4.
Page 5 Flex-Pro 3.0 Features Peristaltic pump design does not have valves that can clog requiring maintenance. Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or lose prime. Variable speed DC motor. Rated for continuous duty (24X7). Specially engineered tubing for long life at high pressures. Meets FDA 21 CFR requirements for food contact applications. Patented Tube Failure Detection (TFD) system. Senses tube failure by detecting chemical in pump head.
Page 6 4.0 Flex-Pro Installation CAUTION ! CAUTION ! CAUTION ! 4.1 Risk of chemical overdose. Be certain pump does not overdose chemical during backwash and periods of no flow in circulation system. Always wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on solution being pumped. Refer to MSDS precautions from your solution supplier. All diagrams are strictly for guideline purposes only.
Page 7 Flex-Pro 4.3 Installing Injection Fitting and Strainer ! CAUTION Proper eye and skin protection must be worn when installing and servicing pump. ! CAUTION This Pump Has Been Evaluated for Use with Water Only. Injection Fitting and Strainer for ½” (1.3cm) I.D. Connection End Models Discharge Injection Fitting / Check Valve) Pipe Tee Install upward for best results ½” (1.3 cm) Male NPT Suction Strainer ½” (1.3 cm) Male NPT or ½” (1.
Page 8 5.0 Flex-Pro Power Connections WARNING Risk of electric shock – cord connected models are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. WARNING Electrical connections and grounding (earthing) must conform to local wiring codes. Be certain that a grounding conductor is connected to terminal T11-1 located in wiring compartment.
Page 9 Flex-Pro 1 2 OUTPUT: 4-20 mA OUTPUT: RELAY, 3 AMP OUTPUT: OPEN COLLECTOR MOTOR ACTIVE 4 (+) POSITIVE T4 3 (+) POSITIVE T4 4 SIGNAL T4 5 (-) NEGATIVE T4 4 SIGNAL T4 5 (-) NEGATIVE T3 1 (+) POSITIVE T3 2 (-) NEGATIVE T3 2 (+) POSITIVE T3 3 (-) NEGATIVE T6 2 (+) POSITIVE T6 1 (-) NEGATIVE T7 1 NORM. CLOSED T7 2 COMMON T7 3 NORM.
Page 10 6.
Page 11 Flex-Pro 6.1 Mode Descriptions Mode 0 - Setup Mode 0 Press and Hold to configure: ŸRemote Start / Stop ŸTFD (Tube Failure Detection) sensitivity ŸFVS (Flow Verification Sensor) time delay - requires sensor Ÿ4-20 mA output, available on certain models Mode 1 - Manual SPEED OFF 2 mA OFF Mode 3 Run pump remotely via external high frequency (Hz) signal. ŸPress and Hold “Select Run Mode” button with Mode 3 selected to configure settings.
Page 12 7.0 Flex-Pro Mode 0 - Set Remote Start / Stop Used to remotely start and stop pump using a dry contact closure signal. When activated; CLOSE = START and OPEN = STOP. Set to NO = Remote Start / Stop is disabled Set to Yes = Remote Start / Stop is enabled Can be used with external foot pedal, PLC, contact closure or other similar external devices. Default setting = No (disabled) Step 1 Mode 0 0 Press and release STOP button Note: Mode cannot be changed while pump is in running.
Page 13 Flex-Pro 7.1 Mode 0 - Set TFD Sensitivity Flex-Pro pump is equipped with a Tube Failure Detection (TFD) system which is designed to stop pump in event pump tube should rupture and chemical enters pump head. This patented system is capable of detection presence of a large number of chemicals including Sodium Hypochlorite (chlorine), Hydrochloric (muriatic) Acid, Sodium Hydroxide, and many others.
Page 14 7.2 Flex-Pro Mode 0 - Set FVS (flow verification system) Flow verification sensor sold separately. Flow verification system is designed to stop pump in an event sensor does not detect flow during pump operation. Indicating an empty chemical tank, clogged injection fitting, loose tubing connection, etc. To allow pump to clear any gasses that may have accumulated over time, an alarm delay time value from 1 to 255 seconds must be programmed. Note: An alarm delay of 000 seconds disables FVS system.
Page 15 Flex-Pro 7.2 Mode 0 - Set FVS (flow verification system) - Continued Flow Verification Sensor is designed to give you two installation options. Sensor can be installed: ! Directly on pumphead of A2 pump, suction side. ! Anywhere on suction side of A2 pump. Wiring for sensor can be connected directly to an A2 pump. Pump will stop pumping if sensor detects no flow. A relay will then close allowing for remote alarm indication or initiation of a back-up injector pump.
Page 16 7.3 Flex-Pro Mode 0 - Set 4-20mA Output Available on certain models. Sends a configurable 4-20 mA signal, based on pump rotor speed, to an external device. This feature can be used to control other pumps (in sync / proportionally), data logging systems, and other external devices for plant automation.
Page 17 Flex-Pro Mode 0 - Set 4-20mA Output - Continued 4-20 mA Icon Step 5 Output signal at minimum speed will now be displayed. To increase value, press and release UP arrow. To decrease value, press and release DOWN arrow. To save value, press and release RIGHT arrow. MAOUT 4 MIN Step 6 4-20 mA Icon Mode 0 0 Maximum pump speed will be displayed. To increase value, press and release UP arrow. To decrease value, press and release DOWN arrow. To save value, press and release RIGHT arrow.
Page 18 8.0 Flex-Pro Mode 1 - Manual Operation Used to manually control speed of pump. Use UP and DOWN arrows to adjust speed while pump is running. To select exact run speed, follow steps below. Step 1 Mode 1 1 Press and release STOP button Note: Mode cannot be changed while pump is in running. Press and release SELECT RUN MODE button multiple times until Mode 1 is selected. Step 2 1 Pump will now operate at your pre-configured speed. Press and release START button to start pump.
Page 19 Flex-Pro 8.1 Mode 1 - Manual Operation Screen Shots Runtime Screen Shot 1 Display motor speed percentage. Pump Running in Manual Operation 1 SPEED 35.0 Runtime Screen Shot 2 Display 4-20mA output (select models only) Press and release RIGHT arrow to view mA output value in real-time. 1 Please note: 4-20mA output is only available on select models. If included in your model; 4-20mA output must be enabled in Mode 0 (see page 16). mA OUT 9.
Page 20 9.0 Flex-Pro Mode 2 - 4-20mA Input Operation 100 Pump Motor Speed (%) Used to remotely control pump with an incoming 4-20 mA signal. Default setting: 4 mA signal = 0.1% motor speed 20 mA signal = 100.0% motor speed Step 1 Default Setting 75 50 25 0 4 6 8 10 12 14 16 18 20 Milliamp Output (mA) Signal Mode 2 2 Press and release STOP button Note: Mode cannot be changed while pump is in running. Press and release SELECT RUN MODE button multiple times until Mode 2 is selected.
Page 21 Flex-Pro 9.0 Mode 2 - 4-20mA Input Operation - Continued Step 6 Mode 2 2 mA value linked to minimum pump speed will now be displayed. To increase value, press and release UP arrow. To decrease value, press and release DOWN arrow. To save value, press and release RIGHT arrow. Step 7 20 Mode 2 To exit Setup, press and hold SELECT RUN MODE button for a few seconds until you return to Run screen.
Page 22 10.0 Flex-Pro Mode 3 - Frequency Input (Hz) Operation Used to remotely control pump with an incoming high speed frequency signal. Typically used with flow meters or other external devices.
Page 23 Flex-Pro 10.0 Mode 3 - Frequency Input (Hz) Operation - Continued Step 5 Mode 3 3 Pump speed at maximum Frequency will be displayed. To increase value, press and release UP arrow. To decrease value, press and release DOWN arrow. To save value, press and release RIGHT arrow. Step 6 SPEED 0.1 Mode 3 Maximum Frequency value will now be displayed. To increase value, press and release UP arrow. To decrease value, press and release DOWN arrow. To save value, press and release RIGHT arrow.
Page 24 11.0 Flex-Pro Mode 4 - Pulse Batch (low speed pulse) Operation Used to remotely control pump with an incoming pulse signal. Can be used with an external foot pedal, a water meter, a PLC, contact closure, or other low speed pulse devices. Default setting: 1 Pulse = 100% motor speed for 2.
Page 25 Flex-Pro 11.0 Mode 4 - Pulse Batch (low speed pulse) Operation - Continued Step 5 Mode 4 4 Number of pulses to trigger pump start will be displayed. To increase value, press and release UP arrow. To decrease value, press and release DOWN arrow. To save value, press and release RIGHT arrow. Hz ON Step 6 Mode 4 4 SPEEDHz Pump speed during on-time will now be displayed. Pump will run at this speed after selected number of pulses is reached from previous menu.
Page 26 12.0 Flex-Pro Pump Tube Timer Flex-Pro has a built in Pump Tube Timer. Timer starts when rotor is rotating and stops when rotor is idle. To view current Pump Tube Timer value, press and hold START button, then press and release DOWN arrow. Tube Timer screen will appear. Screen will display current Pump Tube Time in run-time hours. Tube Timer screen will display for 4 seconds and then switch back to previous operating display screen.
Page 27 Flex-Pro 14.0 Alarm Relay Pump has a built in 3 amp alarm output relay. Relay is pre-configured to energize on tube failure detection (TFD) and on Flow Verification Sensor (FVS). A Flow Verification Sensor must be installed and configured for relay to trigger on no-flow conditions. 15.0 Reverse Rotor Rotation CAUTION ! CAUTION ! Prior to service, pump clean water through pump and suction / discharge line to remove chemical.
Page 28 16.0 Flex-Pro Tube Replacement CAUTION ! CAUTION ! CAUTION ! CAUTION ! 16.1 Prior to service, pump clean water through pump and suction / discharge line to remove chemical. Always wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on solution being pumped. Refer to MSDS precautions from your solution supplier.
Page 29 Flex-Pro 16.2 Tube Installation Before you begin. Thoroughly clean Pump Head and Rotor. Rotor can be removed by pulling straight out. After cleaning process, push Rotor back on shaft. See drawing below for proper assembly. IMPORTANT! Rotor direction; word “FRONT” on Rotor must face forward (front of pump). Installation Tool Step 1 Press and release stop button to ensure pump is stopped. With pump stopped, press suction side of tube adapter securely into pump head.
Page 30 17.0 Flex-Pro Pump Maintenance CAUTION ! Always wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on solution being pumped. Refer to MSDS precautions from your solution supplier. Routine Inspection and Maintenance Pump requires very little maintenance. However, pump and all accessories should be checked weekly. This is especially important when pumping chemicals.
Page 31 Flex-Pro Norprene® Chemical Norprene ® Norprene ® Pump Head Replacement Parts List Tygothane® 18.0 Item Description Part Number QTY 1 Pump Head A2-SXX-H 1 2 Spacer, Back 76001-503 2 Interchangeable Rotor. 3 Roller Assembly Complete (Rotor), For ND and NF Tubes A2-SND-R 1 Tubing in this group are interchangeable with single rotor (roller assembly). 4 Tube Assembly, 3/8” tube connect, Norprene ND (.
Page 32 19.
Page 33 Flex-Pro THIS PAGE INTENTIONALLY LEFT BLANK
LIMITED WARRANTY Your new Flex-Pro pump is a quality product and is warranted for 24 months from date of purchase (proof of purchase is required). The pump will be repaired or replaced at our discretion. Pump Head and roller assembly is warrantied against damage from chemical attack when proper TFD (Tube Failure Detection) system instructions and maintenance procedures are followed.