Blue-White ® Industries, Ltd. DIAPHRAGM INJECTOR MODEL C-600P & C-600HV 5300 Business Drive Huntington Beach, CA 92649 USA Phone: 714-893-8529 FAX: 714-894-9492 E-mails: sales@blue-white.com or techsupport@blue-white.com www.blue-white.
Page 2 C-600 TABLE OF CONTENTS SECTION HEADING PAGE 1 Introduction 2 2 Specifications 2 3 Features 3 4 How to install the metering pump 3 Mount Location 4 4.1 Installation 5 4.2 Electrical connections 6 4.3 How to install the tubing and fittings 7 How to operate the metering pump 9 5.1 Adjusting the Pump Output - Standard Models 9 5.2 Adjusting the Pump Output - Fixed cycle timer Models 9 5.
Page 3 C-600 3.0 Features Double-ball ceramic check valves. ! PVDF (Kynar) valve assemblies. ! Viton o-rings. ! High outlet pressure capability of 125 PSIG.* ! Easy access, side mounted mechanical feed rate adjustment. ! Ball bearing supported motor drive shaft. ! Permanently lubricated ball bearing motor. ! 27:1 adjustment turn down ratio. ! Easy servicing.
C-600 Page 4 C-600P 6-3/4” 171.5mm 5-5/16” 134.9mm 23 4 5 0 1 6-1/4” 158.8mm C-600HV 6.75” 6.125” 23 4 5 7” 0 1 FIG. 4.
C-600 Page 5 Pumping unit Discharge Tube Chemical Container Suction Tube (vertical) WEATHER RESISTANT ¼" & ½" NPT Injector TYPICAL INSTALLATION Stud 5 23 4 23 4 5 0 1 0 1 Stud Mount Masonry WALL MOUNTING
Page 6 C-600 4.2 Electrical Connections Be certain to connect the pump to the proper supply voltage. Using the incorrect voltage will damage the pump and may result in injury. The voltage requirement is printed on the pump serial label. Note: When in doubt regarding your electrical installation, contact a licensed electrician. The metering pump is supplied with a junction box for field wiring.
Page 7 C-600 Cycle Adjustment Potentiometer 120VAC Common Hot Earth Ground (green) 220/230 VAC HOT LOAD Power Cord AC MOTOR Timer Board Neutral Hot FIG. 4.6 WIRING DIAGRAM - FIXED TIMERS 4.3 How To Install the Tubing and Fittings CAUTION: PROPER EYE AND SKIN PROTECTION MUST BE WORN WHEN INSTALLING AND SERVICING THE PUMP Inlet Tubing - Locate the inlet fitting of the pump head. Remove the tube nut. Push the clear PVC suction tubing onto the compression barb of the fitting.
Page 8 C-600 Discharge Tube (Opaque P.E.) Footvalve Adapter Suction Tubing O-Ring Tube Nut Outlet Adapter Pump Head Ceramic Ball Ceramic Weight O-Ring Footvalve Body Inlet Adapter Footvalve Strainer Tube Nut FootValve Assembly Must be installed in a vertical position. Suction Tubing (clear PVC) C-600HV PumpHead FootValve FIG. 4.8 C-600P FootValve Assy. C-600P PumpHead Suction Tubing 4.3.
Page 9 C-600 5.0 How To Operate The Pump 5.1 Adjusting the Pump Output- The flow rate can be adjusted within a range of approximately 10%-100% of maximum output (27:1 turndown ratio) by means of a mechanical, cam type mechanism. The mechanism adjusts the pump’s stroke length to 1 of 27 settings within the flow range.
Page 10 C-600 5.3 Measuring the Pump’s Output - Volumetric Test. This volumetric test will take into account individual installation factors such as line pressure, fluid viscosity, suction lift, etc. This test is the most accurate for measuring the injector’s output in an individual installation. 1. Be sure the Injection Fitting and Footvalve/Strainer is clean and working properly. 2. With the injector installed under normal operating conditions, place the Footvalve/Strainer in a large graduated cylinder.
Page 11 C-600 Exploded View C-600HV 20 31 22 30 21 29 28 25 23 34 33 26 32 1 25 27 24 18 2 19 5 4 3 6 7 8 17 2 16 3 15 7 5 9 2 10 14 2 11 12 13
Page 12 C-600HV Parts List 1. 2. 3. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. Catalog No. C-3391-10 C-3330 C-334-10 4.
Page 13 Exploded View C-600P 11 1 12 25 13 14 2 15 3 4 26 27 15 16 17 18 19 28 20 Optional 22 8 T.I. Anti siphon valve fitting Threaded Anti siphon valve, ¼ & ½” N.P.T.
Page 14 C- 600P Parts List Catalog No. Description Amount Reqd. 1. C-395-6V C-395-6E 2. C-335-6 3. C-330-6 4. K-568V-4 K-568V-10 K-569E-4 K-569E-10 5. C-334-6 6. C-346 7. C-345V C-345E 8. C-535 9. C-504HD 10. C-535FC 11. C-628 12. C-608P 13. C-625 14. C-612F 15. C-612PB 16. C-616PN 17. C-618P-14 C-618P-30 C-618P-45 C-618P-60 C-618P-125 C-618P-250 18. C-301 19. C-624 20. C-325 21. C-304 22. C-406T 23. 90011-155 24. 90002-201 25. C-550-6V C-560-6E 26. 90007-515 27. C-308J 28.
LIMITED WARRANTY Your new pump is a quality product and is warranted to be free of defects as set down in this policy. All parts, including rubberized goods, and labor are covered under warranty for 90 days from the date of purchase. Used peristaltic pump tube assemblies are not warranted. Parts, excluding rubberized goods, are covered under warranty for 12 months from the date of purchase. Warranty coverage does not include damage to the pump that results from misuse, carelessness, abuse or alteration.
Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway.