Intrinsically Safe User Guide Mobile Worker Safety Device Intrinsically Safe
Legal Notices Information in this document is subject to change without notice. This document is provided “as is” and Blackline GPS Inc. (“Blackline GPS" or "Blackline”) and its affiliated companies and partners assume no responsibility for any typographical, technical or other inaccuracies in this document. Blackline GPS reserves the right to periodically change information that is contained in this document.
Table of Contents Safety Precautions DANGER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 WARNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Getting Started Activate your Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Muster Alarm Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Cancelling a Pending No-motion Alert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Silencing a No-motion Alert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Precautions Blackline GPS takes your safety and the safety of those around you very seriously. It is important for you to be aware of the following precautions. DANGER Do not place the Loner 900 product in or near an open flame. WARNING To reduce the risk of ignition of a flammable atmosphere, batteries must only be charged in an area known to be nonflammable. When in a hospital or other health care facility, observe the restrictions on the use of mobile devices, such as cellular phones.
Do Not: Do not operate Blackline GPS products outside their specified operating temperature. Consult the specifications section. Do not store Blackline GPS products outside their specified storage temperature. Consult the specifications section. Do not operate Blackline GPS products outside their specified humidity rating. Consult the specifications section. Do not dispose of Blackline GPS products in your household trash. Seek advice from your local electronics recycling authority.
Getting Started Activate your Device Activation of Loner 900 device is managed within your Loner Portal account by the Blackline GPS Customer Care team. If a Loner Portal account has not been created, the Blackline GPS Customer Care team can provide assistance. 1-877-869-7212 support@blacklinegps.com NOTE: Service activation requires a valid credit card and the Unit ID and Activation Code.
Intrinsically Safe Blackline’s Loner 900 device is a UL 913-certified Intrinsically Safe Apparatus for use in Class I, Division 1, Groups A – D and Class II, Division 1, Groups E – G in hazardous (classified) locations. Please consult with your organization’s safety professional for further information regarding the topic of intrinsic safety and any policies, procedures, facilities, or locations within facilities that may be related to intrinsic safety.
Using Loner 900 Loner 900 Hardware Details Loner 900 is rugged and purpose-built for monitoring you as a mobile worker. Physical details are outlined below.
Indicator Light Array Acknowledge Button (push) Power Button & Indicator Light Emergency Latch (pull) Charging Light (on bottom) Belt Clip Product Label Charging Port Removable Micro USB Charging Clip 9
Charging Loner 900 1. Plug the Wall Charger into an electrical outlet. 2. Insert the Micro USB Cable Plug into the corresponding Micro USB Charging Jack on the charging clip 3. Slide the charging clip onto Loner 900 using the guides to align the clip with the charging port on the device. 4. Completely charge Loner 900 for 3 hours. 5. Remove the charging clip from Loner 900. Charging Loner 900 turns the device Off ensuring it will not trigger alerts while charging.
If Loner 900 fails to connect to Blacklines servers, the device will enter the no communication alarm pattern. Turning Loner 900 Off Follow these steps for turning off the device: 1. Press and hold the Power Button for three seconds to power the device off. The beeper will sound three long beeps while the power button is pressed. The vibration motor vibrates for three long pulses. The beeper, vibration motor and Power Button Indicator Light will turn off after three seconds.
Loner 900 Light Annunciation Patterns Loner 900 features audible, tactile and visual indicators for annunciating different types of messages. Please see below for these patterns.
Alerts Alert messages are configured for Loner 900 through the Loner Portal web app. Loner Portal displays alerts and they can be sent via email and SMS to safety monitoring personnel. Understanding Alerts An alert is a message that communicates a device or system level event, such as an Emergency Alert or a Low Battery Alert. Depending on the priority level of the Alert, different action must be taken by safety-monitoring personnel.
Initiating an Emergency Alert (Emergency Latch Use) If you are in an emergency situation, perform the following: 1. Open the Emergency Latch. Loner 900 will instantly send an Emergency Message to Loner Background Services. Loner 900 will annunciate the high alarm pattern to notify others nearby of the event. The alarm pattern on Loner 900 will continue until the Emergency Alert has been canceled or the battery is depleted.
Muster Alarm Light A blue LED on either side of the Loner 900 will light up if the unit is in a state of return-tomuster or if there is an emergency text message at the BRidge that requires action. Cancelling a Pending No-motion Alert 1. Press the acknowledge button for 1 second during the pending No-motion Alarm. After one second, the alarm pattern will be silenced and Loner 900 will return to regular operation.
If you have not cancelled the alert within 30 seconds, the Fall Detected Alert is sent, initiating the alert escalation process. Loner 900 will annunciate the high alarm pattern and will continue until the alert is silenced or the battery is depleted. Silencing a Fall Detected Alert 1. Press and hold the acknowledge button for 3 seconds. After three seconds, the pending alarm pattern will be silenced and the Loner 900 will return to regular operation.
Loner 900 will continue all of the alarms until one of the following occurs: Loner 900 automatically shuts down with a depleted battery; or Loner 900 is plugged in for charging. Loner 900 sends a Loner 900 Powered Off by Low Battery message to the Loner Background Services before finally powering off. If Loner 900 powers off with low battery, it will annunciate with a three second beep, vibrate and indicator light array flash. Troubleshooting Subtext goes here introducing the following section.
18 // USER GUIDE
Specifications Specifications for Loner 900 Size & Weight Size: 63 mm W x 107 mm L x 22 mm D (2.48” W x 4.21" L x 0.87" D) Weight: 137 g (4.
Loner 900 Care Consideration Regarding Use and Storage of Loner 900 Loner 900 meets IP65 ingress protection ensuring that under normal operation no dirt or water can enter the device. Storage temperature range: -30 to 75° C (-22 to 167° F) Operating temperature: -20 to 55° C (-4 to 131° F). Charging temperature: 0 to 45° C (32 to 113 °F) More details can be found in the specifications section.