G7 Technical User Manual
CONTENTS OVERVIEW Real-time connected safety................................................................................................................ 4 Blackline Safety Network ..................................................................................................................... 4 Blackline Live web portal..................................................................................................................... 5 G7 models ....................................................
GAS DETECTION Bump test ..................................................................................................................................................... 24 Calibration ................................................................................................................................................... 26 Zero sensors.................................................................................................................................................
OVERVIEW REAL-TIME CONNECTED SAFETY What is G7? G7 is the first true work-everywhere, wearable, personal safety monitor. It keeps you connected — whether it’s a gas leak, a health incident or an intruder. Your G7 can trigger a facility evacuation, accounting for your location on a real-time map. Should you require help, G7 delivers the instant situational awareness needed to manage the fastest possible response to make a difference. G7 has your back at all times.
BLACKLINE LIVE WEB PORTAL What is Blackline Live? G7 utilizes the cloud-hosted Blackline Live web portal to monitor and manage all your workers and devices. With Blackline Live’s real-time alerting and live map with employee locations, you can quickly locate and respond to a worker in distress. Real-time alerts show the employees location on the map with the type of alert, enabling your team to efficiently send the help they need.
G7 MODELS What G7 model do I have? There are two G7 models: G7c and G7x. The main difference between them is how they connect to the Blackline Safety Network. If you are unsure of which G7 model you have, refer to the logo on the front of your G7. G7C G7c works anywhere with 2G/3G cellular coverage in over 200 countries to connect you directly to the Blackline Safety Network. Depending on your service plan, your G7c may have two-way voice capabilities.
DEVICE COMPARISON What features does my G7 have? G7c and G7x are customized with one of three cartridge types. Cartridge selections include Standard, Single-gas and Quad-gas cartridges. The following comparison chart summarizes the features of each cartridge.
WHAT’S IN THE BOX Your G7 device comes with the following components: G7 personal safety monitoring device Pre-installed cartridge (Standard, Single-gas or Quad-gas cartridge) Quick start guide Charging system • Removable charging clip • USB cable • USB power adapter Certification and support card If you have a Single-gas or Quad-gas cartridge you will also receive: Gas detection guide Single or Quad calibration cap (depending on your cartridge) Calibration gas tubing 8 || G7 TECHNI
HARDWARE DETAILS Top lights Pending and warning Alerts LiveResponse Cartridge (Standard, Single-gas or Quad-gas) LCD screen Up button OK OK button SureSafe Speaker Down button Latch pull Power button Latch push button Microphone (G7c only) Charging light Cartridge label Metal belt clip Product label Charging port G7 TECHNICAL USER MANUAL || 9
INTERACTION HOW IT WORKS Interacting with G7 is easy with it’s high-visibility LCD display and three-button menu system. OK button Press OK to enter the main menu on the LCD screen and to confirm a menu selection. Up and down arrow buttons Press up or down to navigate the menu. Press and hold both simultaneously to mute a yellow warning alarm or red alert. Latch pull Pull down the latch to call for help when assistance is required.
NOTIFICATIONS When G7 has something to tell you it uses color, vibration, sound and on-screen messages. SureSafe Are you Connected? G7 lets you know your connection status. Green SureSafe Blinking/Solid Blinking green light A blinking green SureSafe® light indicates your device is connecting to the Blackline Safety Network and your safety is not yet monitored. Solid green light A solid green SureSafe light indicates you’re connected and being monitored by the Blackline Safety Network.
YELLOW PENDING ALARM Are you safe? G7 is asking you to confirm that you are safe. Yellow Pending Alarm Blinking Push the red latch button within a set period of time to confirm you are safe. If you don’t push the latch button your G7 will communicate a red alert to monitoring personnel. Sound and Vibration Beeping alarm sound — an alarm sound and vibration, a pause, then an alarm sound and vibration and another pause, etc.
YELLOW WARNING ALARM G7 has a message for you Read your G7 screen. Yellow Warning Alarm Rapid Blinking Press and hold the up and down buttons at the same time to let your G7 know you have read the message. This will disable the audible and visual alarm. Sound and Vibration Urgent alarm sound — an alarm sound and vibration, a pause, another alarm sound and vibration, another pause, etc. (Faster than yellow pending alarm sound).
RED ALERT We’re here to help If you need assistance or have not responded to a yellow pending alarm. Red Alert Rapid Blinking Red alerts are immediately communicated to monitoring personnel. Read the information on your screen. Press and hold the up and down buttons simultaneously to mute. Muting will only silence the sound and vibration and does not cancel the alert to monitoring personnel. Sound and vibration Critical alarm sound — an urgent sound and a constant vibration without any pauses.
LiveResponse We’ve got your back Monitoring personnel have acknowledged your red alert. LiveResponse Blinking Lets you know that remote monitoring personnel are responding by following your team’s emergency protocol. Once monitoring personnel have resolved the red alert, the blue LiveResponse™ light will shut off. Sound and Vibration Depending on your response protocol, a G7c with voice enabled service plan will automatically connect your speaker phone to monitoring personnel.
OPERATING CHARGING How do I charge my G7? Insert the micro USB plug into the removable charging clip, then slide the clip onto the charging port at the bottom of your G7. A solid red light at the bottom of the device confirms your G7 is charging. The LCD screen will let you know when it is fully charged. Blackline recommends that you fully charge your device after every shift. NOTE: Charging will automatically turn your G7 off to ensure it will not trigger alerts while in the charging process.
POWER ON How do I turn on my G7c? Press and hold the power button, and wait for the blinking green SureSafe light to turn solid. Once connected, the green light will stay on and your safety is being monitored. How do I turn on my G7x? Press and hold the power button on your G7 Bridge to turn it on first, and wait for the blinking green SureSafe light to turn solid, It takes approximately two minutes for G7 Bridge to connect to the Blackline Safety Network. Once connected, the green light will stay on.
SAFETY MONITORING FEATURES Your G7 is equipped with many features to monitor your safety. They are categorized into the type of notifications they trigger — yellow pending alarms, yellow warning alarms, and red alerts. All are customizable in Blackline Live to best fit your needs. Speak to your safety supervisor to learn about how your G7 features are configured.
POTENTIAL NO-MOTION DETECTED What is a potential no-motion detected? Your device is constantly monitoring your motion. It will automatically detect if you do not move within a pre-set duration, and will initiate a yellow pending alarm. The no-motion period and sensitivity are configurable. CHECK-IN REQUEST What is a check-in? If enabled, you can configure your device to request periodic check-ins throughout your shift. The check-in countdown is displayed at the top right of the LCD screen.
YELLOW WARNING ALARM FEATURES Rapid Blinking MESSAGES How do I receive a message? Your device can receive messages from monitoring personnel. When there is an incoming message, G7 will inform you with a yellow warning alarm. How do I send a message? You can choose from a list of 10 pre-programmed messages to send to monitoring personnel. The messages can be pre-programmed on Blackline Live.
SPEAKER PHONE How do I use two-way voice calling? If you have a G7c with a voice-enabled service plan, your speakerphone will automatically answer a call from monitoring personnel. G7 will inform you of an incoming call with a yellow warning alarm. The blue LiveResponse light will blink and you will hear a beep signifying the two-way voice call has been connected. In a noisy environment, it may be necessary to remove and hold the device near your ear, as you would a two-way radio.
RED ALERT FEATURES Rapid Blinking FALL DETECTED What is fall detected? If your device detects a fall and you have not responded to the yellow pending alarm, G7 will communicate a red alert to monitoring personnel. The fall detection sensitivity is configurable. NO-MOTION DETECTED What is no-motion detected? If you are not moving and you have not responded to the yellow pending alarm, G7 will communicate a red alert to monitoring personnel. The no-motion period and sensitivity are configurable.
MISSED CHECK-IN What is a missed check-in? If enabled and you are unable to check-in during the yellow pending alarm time, your device will communicate a red alert to monitoring personnel. SOS ALERT What is an SOS Alert? If you require assistance, you can manually send an SOS alert to monitoring personnel requesting immediate help to your location by pulling the red latch. NOTE: Your device can be configured to send a Silent SOS alert to monitoring personnel without light, sound and vibration.
GAS DETECTION Included with your G7 Single-gas or Quad-gas cartridge is a calibration cap and tubing for bump tests and calibrations. Alternatively, bump tests and calibrations can be completed using a G7 Dock. Only perform bump test and calibrations in a safe environment. For more information and instructions, refer to the G7 Dock technical user manual.
Tubing Single-gas calibration cap Tubing Quad-gas calibration cap G7 TECHNICAL USER MANUAL || 25
CALIBRATION What is calibration? Gas sensors periodically need to be calibrated by applying a known concentration of gas for a set amount of time. This procedure ensures the gas sensor can accurately detect gas levels throughout its operating life. The calibration schedule depends on your company’s safety policy. Blackline recommends not exceeding 180 days without a calibration. How do I calibrate? 1. Attach tubing to the calibration cap 2. Ensure the other end of the tubing is attached to a 0.
ZERO SENSORS What is zeroing? If G7 is not reading zero and you know you are in an atmosphere with no gas, your gas sensor readings may have shifted. If this happens, it is best to calibrate your sensors. If you are unable to preform a calibration, you can zero your sensors to reset the baseline. G7 can be configured to automatically zero on start-up when you turn on your device in Blackline Live. NOTE: The baseline reading for oxygen is 20.9. How do I zero sensors? 1.
GAS DETECTION FEATURES Once you have completed the bump test and calibration, your G7 is ready to monitor and notify you of gas exposure. Gas detection alarms will notify you with either a yellow warning alarm or a red alert depending on the gas level measured. All settings are customizable in Blackline Live. Speak to your safety supervisor to learn about how your G7 gas features are configured.
UNDER LIMIT When does G7 trigger an under limit yellow warning alarm? If a gas sensor’s baseline shifts, it’s reading will shift accordingly and become unreliable. When this happens, the presence of gas can still be measured, but cannot be converted into an accurate reading. G7 will inform you of such an event with a yellow warning alarm. A calibration will be required to ensure the sensors are accurately detecting gas levels.
RED ALERT GAS FEATURES Rapid Blinking HIGH ALERT FOR GAS When does G7 trigger a high alert for gas? If a gas sensor detects gas levels above the maximum gas concentration configured by your safety supervisor, G7 will communicate a red alert to monitoring personnel. NOTE: A G7 with O2 sensors will trigger red alerts in both oxygen-deficient and oxygenenriched situations.
TWA (TIME WEIGHTED AVERAGE) ALERT When does G7 trigger a TWA alert? If a toxic sensor detects you have exceeded the average allowable amount of gas during an eight-hour period, G7 will communicate a red alert to monitoring personnel. NOTE: The two TWA measuring methods available for use on your G7 are: OSHA (United States Department of Labor Occupational Safety and Health Administration) or ACGIH (American Conference of Governmental Industrial Hygienists).
CARTRIDGES GAS CARTRIDGE REPLACEMENT PROGRAM What do I do when I need a new gas cartridge? If you have an uninterrupted service plan for your G7 gas cartridge, Blackline will replace expired cartridges for you free of charge. To inquire about or request new cartridges, please contact our Customer Care team or your distributor. CHANGING CARTRIDGES How do I change my G7 cartridge? 1. Power off G7 2. Using a Torx T8 screwdriver, remove the screws on each side of the device 3. Pull up on the cartridge 4.
CARTRIDGE CARE Sensor contaminants Gas sensors are susceptible to contamination by a variety of common chemicals, reducing or eliminating their sensitivity. Care should be taken when using silicones, cleaners, solvents and lubricants in close proximity to sensors as exposure may cause permanent damage to the sensor. If a device is exposed to a new chemical or compound, it is best practice to bump test and calibrate units to ensure proper sensor function is maintained.
FIRMWARE UPDATES OVER-THE-AIR (OTA) FIRMWARE UPDATES How does G7 get updated? To offer new features, Blackline Safety periodically releases over-the-air (OTA) firmware updates. Your G7 device will automatically download and install the new firmware. Blackline Safety will contact you directly for specific information about new updates. If you have any questions, please contact our Customer Care team. NOTE: OTA firmware updates are only available for G7 Bridge when it is brought into cellular range.
SUPPORT LEARN MORE Visit support.BlacklineSafety.com to find support and training materials for G7. CUSTOMER CARE For technical support, please contact our Customer Care team. North America (24 hours) Toll Free: 1-877-869-7212 | support@blacklinesafety.com United Kingdom (8am-5pm GMT) +44 1787 222684 | eusupport@blacklinesafety.com International (24 hours) +1-403-451-0327 | support@blacklinesafety.
SPECIFICATIONS DETAILED SPECIFICATIONS Standard G7 Safety Alert Features Gas Sensor Options All safety alerts are transmitted in real-time to the Blackline Safety Network HS, LEL, CO, O2, CO2, NH3 Fall detection and No-motion detection: Tri-axis accelerometer, tri-axis gyro, software processing, configurable sensitivity, configurable time window (1–30 mins, or off ) for no-motion detection SOS latch: Pull latch to trigger remote alert Silent emergency: Press and hold latch to trigger remote alert Low-b
User Interface 168 by 144 pixel graphical, high contrast, liquid crystal display with front lighting, menu system driven by three-button keypad, power button (on/ off), check-in button (check-in/silent SOS), SOS latch (send emergency alert) User Notification Green SureSafe® light: Blinking (powered), continuous (connected) Yellow top and front lights: Personal pending alarm and personal warning alarm Red top and front lights: Alert communicated Blue LiveResponse™ top and front lights: Monitoring team confi
LEGAL NOTICES AND CERTIFICATIONS LEGAL NOTICES Information in this document is subject to change without notice. This document is provided “as is” and Blackline Safety Corp. (“Blackline”) and its affiliated companies and partners assume no responsibility for any typographical, technical or other inaccuracies in this document. Blackline reserves the right to periodically change information that is contained in this document.
INTRINSICALLY SAFE Intrinsically Safe This device is certified Intrinsically Safe for use in Class I Division 1 Groups A,B,C,D T4; Ex ia IIC T4 Ga; Class I Zone 0 AEx ia Group IIC T4 Ga hazardous (classified) locations. G7x is certified as Ex ib IIC T4 Gb under IECEx. Sécurité intrinsèque Cet appareil est certifié à sécurité intrinsèque pour l’usage en classe I division 1 groupe A,B,C,D T4; Ex ia IIC T4 Ga; classe I zone 0 AEx ia groupe IIC T4 Ga dans les lieux classés comme dangereux.
www.BlacklineSafety.