— C ATA LO G Blackburn® Mechanical connectors
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Thomas & Betts is now ABB Installation Products, but our long legacy of quality products and innovation remains the same. From connectors that help wire buildings on Earth to cable ties that help put machines in space, we continue to work every day to make, market, design and sell products that provide a smarter, safer and more reliable flow of electricity, from source to socket.
— Table of contents 004 Overview 005 –008 Split-bolt connectors 009 – 010 Service post connectors 011 Parallel groove connectors 012 Insulation piercing connectors 013 – 014 Two-bolt connectors 015 – 022 Insulated multi-taps 023 – 025 Power distribution blocks 026 – 033 Dual-rated mechanical connectors 034 – 042 Copper mechanical connectors 043 Clamp connectors 044 – 047 Index
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Overview — 01 Copper splitbolt connectors See page 5 — 02 Aluminum splitbolt connectors See page 7 — 03 Service post connectors See page 9 — 04 ViceLock See page 11 — 05 Insulation piercing connectors See page 12 — 06 Two-bolt connectors See page 13 — 07 CSB and AMT connectors See page 15 — 08 Power distribution blocks See page 23 — 09 Dual-rated mechanical connectors See page 26 — 10 Dual-rated mechanical connectors See page 31 — 11 Splicer re
S P L I T- B O LT C O N N E C TO R S — Split-bolt connectors Type H – High-strength split-bolt connectors For copper-to-copper connections. • Bolt and nut of high-strength corrosion-resistant bronze alloy • Pressure bar is copper through 40H, copper alloy for 350 kcmil and above • Bolt and nut of hex design up to 350 kcmil • Tested and listed to UL486C, UL467 for grounding and for direct burial through Cat. No. 40H — Type H – High-strength split-bolt connectors Cat. no.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 6 — Split-bolt connectors Type HPS – Plated split-bolt connectors with spacer For use on copper, aluminum and ACSR conductors.
S P L I T- B O LT C O N N E C TO R S — Split-bolt connectors Type HPW and Type APS For combinations of copper, aluminum and ACSR conductors.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 8 — Split-bolt connectors Type AAW and Type CA For all-aluminum applications.
S E R V I C E P O S T C O N N E C TO R S — Service post connectors For grounding of steel structures, fence posts or transformers using one or two cables.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 10 — Service post connectors Single- and double-conductor service post connectors, short stud and long stud — Single- and double-conductor service post connectors, short stud Conductor range AWG (mm2) Cat. no. Stranded Solid Dimensions (in.) SP-DS SP-SS Max. Min. Max. Min. Diameter range (in.) SP0DS SP0SS 8 (6) 12 (4) 8 (10) 12 (4) 0.146–0.081 – 1 11 13 ⁄16 1 55 15 SP1DS SP1SS 7 (10) 10 (6) 6 (10) 10 (6) 0.164–0.
PA R A L L E L G R O O V E C O N N E C TO R S — Parallel groove connectors Blackburn® bronze Vicelock® connectors Create a superior electrical connection – While saving time and money.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 12 — Insulation piercing connectors Type IPC – Talon insulation piercing connectors No need to strip conductor insulation or use tape after installation.
T W O - B O LT C O N N E C TO R S — Two-bolt connectors Type 2B and 2BX Neoprene washers capture bolts in bottom casting for easy installation. • Castings and bolts of high-strength copper alloy • Removable cap • UL® 486A listed for copper conductor only — Type 2B – Two-bolt connector without spacer Conductor range (AWG or kcmil) Main Cat. no. Diagram L B H Conductor diameter (B) Max. Min. Max. Min. Max. 2B10 1/0 Str. 2 Str. 1/0 Str. 10 Sol. 0.746 0.394 2B20BB 2/0 Str. 2 Str.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 14 — Two-bolt connectors Type 2BW and Type 2BPW Ringed, contoured spacer swings easily over conductor. • For use on copper conductors only • Single-piece construction spacer • Castings and bolts made of high-strength copper alloy • Spacer made of ductile, high-conductivity copper alloy • UL® 486A listed for copper conductor only — Type 2BW – Two-bolt connector with spacer Conductor range (AWG or kcmil) Main Cat. no. Diagram L B Max.
I N S U L AT E D M U LT I -TA P S — Insulated multi-taps Aluminum multi-tap encapsulated cable blocks – One-way configuration CSR 2/0 These dual-rated blocks can be used with copper or aluminum cable. • Versatile design supports a wide range of cable sizes and number of outlets available in one-way configurations • Clear PVC insulation enables safe and time-saving installation with no taping required • Meets or exceeds ANSI C119.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Insulated multi-taps Aluminum multi-tap encapsulated cable blocks – Two-way configuration CSB 500-8 These dual-rated blocks can be used with copper or aluminum cable. • Versatile design supports a wide range of cable sizes and number of outlets available in one-way configurations • Clear PVC insulation enables safe and time-saving installation with no taping required • Meets or exceeds ANSI C119.
I N S U L AT E D M U LT I -TA P S — Insulated multi-taps AMT connectors Superior connections with lower installation costs. • PVC insulation eliminates insulation failures and reduces outage costs • UV-resistant material • Compact design provides space efficiencies • UL® listed The high quality and built-in flexibility of Blackburn® AMT connectors reduce the cost of field installations on splices, taps and terminations.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Insulated multi-taps AMT multi-port connector “same side” — AMT aluminum splice Fig. No. of ports Wire range (AWG or kcmil) Hex size (in.) Std. pkg. qty. AMTC4 2 2 4–14 Str. 1.11 AMTS4142 2 2 4–14 Str. 1.24 1.10 1.35 Slotted screw 25 1.22 1.42 1 AMTS4143 4 3 4–14 Str. 1.7 12 1.22 1.42 1 AMTS4144 4 4 4–14 Str. 12 2.16 1.22 1.42 1 AMTS4145 4 5 6 4–14 Str. 2.61 1.22 1.
I N S U L AT E D M U LT I -TA P S — Insulated multi-taps AMT multi-port connector “same side” (continued) — AMT aluminum splice (continued) Fig. No. of ports Wire range (AWG or kcmil) Length (in.) Width (in.) Height (in.) AMTS25068 4 8 250–6 Str. 7.53 1.91 2.17 5 AMTS25069 4 9 250–6 Str. 8.42 1.91 2.17 5 3 AMTS250610 4 10 250–6 Str. 9.32 1.91 2.17 5 2 Cat. no. Diagrams Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Hex size (in.) ⁄16 ⁄16 ⁄16 Std. pkg. qty.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Insulated multi-taps AMT multi-port connector “double” both sides — AMT multi-port connector “double” both sides Fig. No. of ports Wire range (AWG or kcmil) Length (in.) Width (in.) Height (in.) AMTD4142 5 2 4–14 Str. 1.24 1.25 1.42 1 12 AMTD4143 5 3 4–14 Str. 1.7 1.25 1.42 1 12 AMTD4144 5 4 4–14 Str. 2.16 1.25 1.42 1 6 AMTD4145 5 5 4–14 Str. 2.61 1.25 1.42 1 6 AMTD4146 5 6 4–14 Str. 3.07 1.24 1.
I N S U L AT E D M U LT I -TA P S — Insulated multi-taps AMT multi-port connector “double” both sides (continued) — AMT multi-port connector “double” both sides (continued) Fig. No. of ports Wire range (AWG or kcmil) Length (in.) Width (in.) Height (in.) AMTD250611 5 11 250–6 Str. 10.21 2.13 2.17 5 2 AMTD250612 5 12 250–6 Str. 11.1 2.13 2.17 5 2 AMTD250613 5 13 250–6 Str. 12 2.13 2.17 5 1 AMTD250614 5 14 250–6 Str. 12.89 2.13 2.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Insulated multi-taps AMT multi-port connector “double” both sides (continued) — AMT multi-port connector “double” both sides (continued) Fig. No. of ports Wire range (AWG or kcmil) Length (in.) Width (in.) Height (in.) AMTDM3067 5 7 3/0–6 Str. 7.24 1.68 1.86 3 3 AMTDM3068 5 8 3/0–6 Str. 8.01 1.68 1.86 3 2 AMTDM3069 5 9 3/0–6 Str. 8.77 1.68 1.86 3 2 AMTDM30610 5 10 3/0–6 Str. 9.54 1.68 1.
P O W E R D I S T R I B U T I O N B LO C K S — Power distribution blocks Blackburn® power distribution blocks are suitable for all panel building applications and various terminal enclosure solutions; for extending or branching the cables or changing the conductor type.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Power distribution blocks Conductor table — Conductor table Diagrams Figure 1 Conductors that can be used with the power distribution blocks – Number, cross-section and type.
P O W E R D I S T R I B U T I O N B LO C K S — Power distribution blocks — Power distribution blocks Cat. no. Wire range (AWG or kcmil, Cu or Al) Max. Tightening current torque (A Cu/A Al) (lb.-in.) Allen hex socket head terminal screw (mm) Mounting Overall dimensions (in.) Color Pkg. qty. Terminal blocks PDS610 1/0 – 6 150/120 90 5 Top hat rail 0.7 W x 1.9 H x 1.7 D Gray 30 PDS610B 1/0 – 6 150/120 90 5 Top hat rail 0.7 W x 1.9 H x 1.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 26 — Dual-rated mechanical connectors Anti-rotational connectors “No-turn” design keeps connector securely in place – Even under vibration. Blackburn® anti-rotational connectors are designed with a rib on the bottom that keeps the connectors from turning, so there’s no need to apply excessive torque and there’s no danger of loosening connectors.
D U A L- R AT E D M E C H A N I C A L C O N N E C TO R S — Dual-rated mechanical connectors Type ADR – ALCÜL™ single-conductor, one-hole mount and two-hole mount • All-aluminum-body lugs for use on copper and aluminum conductors • Easy installation – No special tools required • Tin plated for low contact resistance — Type ADR – ALCÜL single-conductor, one-hole mount* Conductor range AWG or kcmil (Al or Cu) Cat. no. Diagrams Dimensions (in.) Max. Min. L W H D E F G #6 Str.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 28 — Dual-rated mechanical connectors Type ADR – ALCÜL™ single-conductor, switchgear mount and two-conductor, one-hole mount — Type ADR – ALCÜL™ single-conductor, switchgear mount* Conductor range ( AWG or kcmil, Al or Cu) Cat. no. Dimensions (in.) Max. Min. L W ADR25-12S 250 3/0 Str. 3 1 ADR35-12S 350 4 Str.
D U A L- R AT E D M E C H A N I C A L C O N N E C TO R S — Dual-rated mechanical connectors Type ADR – ALCÜL™ two- and three-conductor, two-hole mount Fig. 1 Fig. 2 — Type ADR – ALCÜL two-conductor, two-hole mount* Conductor range ( AWG or kcmil, Al or Cu) Cat. no. Dimensions (in.) Fig. Max. Min. L W H D E ADR35-22 1 350 6 Str. 41⁄4 219⁄ 64 13⁄ 8 5 1 ADR60-22D 2 600 2 Str.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 30 — Dual-rated mechanical connectors Type ADR – ALCÜL™ three- and four-conductor, four-hole mount Fig. 1 Fig. 2 — Type ADR – ALCÜL three-conductor, four-hole mount** Conductor range (AWG or kcmil, Al or Cu) Cat. no. Diagrams W I D F Max. Min. L W 1 2 Str. 14 23⁄16 15⁄ 8 ADR02-34 L “E” bolt size 1 ⁄4 3 H H D 5 11 7 11 ⁄8 ⁄ 32 E 5 ⁄16 F G ⁄16 111⁄16 9 ⁄4 25⁄ 32 45 ⁄16 3 31 31 3 ADR11-34 1 1/0 Str.
D U A L- R AT E D M E C H A N I C A L C O N N E C TO R S — Dual-rated mechanical connectors Type ASL – ALCÜL two-conductor, one-hole mount and Type ASL – ALCÜL™ two-, and three-conductor, two-hole mount — Type ASL – ALCÜL two-conductor, one-hole mount Conductor range (AWG or kcmil, Al or Cu) Cat. no. Diagrams ⁄ dia. 13 32 ASL30-21 Min. L W H 300 6 Str. 3 11⁄ 8 2 1 15 ⁄ 32 5 ⁄2 ⁄16 D 1 3⁄8 1 3⁄16 Dimensions (in.) Mtg. hole D F dia. Max.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 32 — Dual-rated mechanical connectors Type ASL – ALCÜL four-conductor, two-hole mount and type ASR – ALCÜL™ and Type BX – ALCÜL — Type ASL – ALCÜL four-conductor, two-hole mount Conductor range (AWG or kcmil, Al or Cu) Cat. no. Diagrams 1 3⁄16 1 3⁄8 1 3⁄8 F 1 3⁄32 dia. 2 holes Dimensions (in.) Max. Min. L W H D F I ASL60-42 600 2 Str. 4 29⁄ 32 21⁄ 2 3 3 3 ⁄8 17⁄ 32 ASL75-42 750 3/0 Str.
D U A L- R AT E D M E C H A N I C A L C O N N E C TO R S — Dual-rated mechanical connectors Type GP, Type GT, Type TC and Tightening torque values for aluminum dual-rated socket screw connectors — Type GP – Aluminum dual-rated mechanical parallel tap connectors Conductor range (AWG or kcmil, Al or Cu) Cat. no. Diagram Tap 2–12 Str.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 34 — Copper mechanical connectors Type L, Type TL and Type S • Cat. nos. L400 and L650 cast from high-strength bronze alloy • Cat. nos. L35, L70, L125 and L250 cold forged from pure electrolytic copper with 99% conductivity — Type L – Single-conductor, one-hole mount Cat. no. Diagrams G E L H D J F W Conductor range (AWG or kcmil) Dimensions (in.) Socket Hex Max. Min. L W L35* – 8 Str. 14 Sol. 13 L70* – 4 Str. 14 Sol.
C O P P E R M E C H A N I C A L C O N N E C TO R S — Copper mechanical connectors Direct-burial splice kits, Type STC and Type BTC DBSK82 UFSK148DB — Direct-burial splice kits Description Wire range (AWG) UF direct-burial splice kit #14–#8 10 Direct-burial splice kit (non-UF) #8–#2 10 Cat. no. UFSK148DB DBSK82 Std. pkg. qty. • Uniquely designed pressure bar and notched V-bottom collar provide vise-like grip between conductor and terminal • Fast, easy installation.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 36 — Copper mechanical connectors LOCKTITE® one-hole lugs and one-hole flag-type lugs Only nine lug sizes fit cables from #14 to 1000 kcmil. • Easily installed with key wrench • Saddle and cable socket make direct, all-around, low-resistance contact with cable • Convenient peephole permits easy inspection • For use with code copper conductor (600 V) — LOCKTITE one-hole lugs Cat. no.
C O P P E R M E C H A N I C A L C O N N E C TO R S — Copper mechanical connectors LOCKTITE® one-hole 90° upright lugs, two-hole lugs and two-hole NEMA-drilled lugs • For use with code copper conductor (600 V) • All the outstanding LOCKTITE lug features – Plus two-bolt capacity — LOCKTITE one-hole 90° upright lugs Dimensions (in.) Cable size (AWG) Cat. no.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 38 — Copper mechanical connectors LOCKTITE® double- and triple-barrel NEMA-drilled lugs for 600 V applications All the same features as the standard LOCKTITE lug – With two or three barrels. • Screw tightening • Serrated saddle • Built-in lockwasher • For use with code copper conductor (600 V) — LOCKTITE double- and triple-barrel NEMA-drilled lugs for 600 V applications Cable size (AWG or kcmil) Fig. 32003BD † 14–8 A 32005BD† 8–4 A Cat. no.
C O P P E R M E C H A N I C A L C O N N E C TO R S — Copper mechanical connectors LOCKTITE® two-way connectors and tee-parallel taps Join two cables end-to-end. • Cables held by saddle and tightened by screws • Built-in lockwashers • For use with code copper conductor (600 V) — LOCKTITE two-way connectors Diagrams EE A A A 32503† 14 Sol.–8 Sol. 11⁄ 8 3 32505† 8 Sol.–4 Str. 13⁄ 8 1 17 32507 4 Sol.–1 Str. 5 1 ⁄8 5 27 32509 1 Sol.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 40 — Copper mechanical connectors LOCKTITE® tandem-type two-hole NEMA-drilled lugs, ground bus taps and pigtail connectors For stranded, solid, flexible and other types of cables. • Each lug takes a range of wire sizes • Bolt holes and spacings listed are standard • For use with code copper conductor (600 V) — LOCKTITE tandem-type two-hole NEMA-drilled lugs Cat. no.
C O P P E R M E C H A N I C A L C O N N E C TO R S — Copper mechanical conductors LOCKTITE® stud connectors and LUG-IT one-hole lugs • Fast, simple installation • Convenient pigtail is easy to tape • To order with hex head screws, add prefix H to catalog number • Standard tapping shown in diagrams • Other tapping to meet specific requirements available on request • For use with code copper conductor (600 V) — LOCKTITE stud connectors Male – Type MS Diagrams Type MS B E A A F Female – Type FL Dim
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S 42 — Copper mechanical conductors LOCKTITE® cone screw lugs and HINJON junior tee-parallel taps High pull-out strength and low resistance.
C L A M P C O N N E C TO R S — Clamp connectors XT™ clamp for tee tap, cross, parallel and end-to-end connectors and DLC™ single U-bolt aluminum fittings Connectors for a variety of applications. • Copper alloy castings provide high strength for heavy-duty applications • Silicon-bronze bolts built to handle frequent moves, adds and changes — XT clamp for tee tap, cross, parallel and end-to-end connectors Conductor range (AWG or kcmil) Main Cat. no. Diagrams XT12 A H B Max. Min. Max. Min. Max.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Appendix Part number index Cat. no. Page Cat. no. Page 1000HPS Page 6 Cat. no. 31003 Page 36 Cat. no.
APPENDIX — Appendix Part number index Cat. no. Page Cat. no. Page Cat. no. Page Cat. no.
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S — Appendix Part number index Cat. no. Page Cat. no. Page Cat. no. Page Cat. no.
APPENDIX 47 — Appendix Part number index Cat. no. Page Cat. no. Page Cat. no.
— Notes B L A C K B U R N M E C H A N I C A L C O N N E C TO R S
N OT E S — Notes 49
B L A C K B U R N M E C H A N I C A L C O N N E C TO R S Additional information We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein.
— US ABB Installation Products Electrification business 860 Ridge Lake Blvd. Memphis, TN 38120 +1 901-252-5000 © Copyright 2019 ABB. All rights reserved. Specifications subject to change without notice. 7TKK000129.5.2019 tnb.abb.