Software Description Advant Controller 31 Intelligent Decentralized Automation System Installation Series 90 and Series 40/50 07 KP 90 07 KT 97 07 DC 92 07 AC 91
Contents 1 Contents of the CD-ROM 907 AC 1131 V5.x 1 1.1 The CD-ROM menu 1 1.2 1.2.1 1.2.2 1.2.3 1.2.4 1.2.5 1.2.6 1.2.7 The installation menu of 907 AC 1131 Installation sequence Installing the programming software 907 AC 1131 Installing the field bus configurator 907 FB 1131 Installing the OPC server Installing the ENI server Installing the PCI driver for the slot PLC 07 SL 97 Installing the communication drivers (gateway and dlls) 3 4 5 7 8 9 10 12 1.3 1.3.1 1.3.2 1.3.
.4.3 4.4.4 4.4.
1 1.1 Contents of the CD-ROM 907 AC 1131 V5.x The CD-ROM menu If the CD-ROM drive on your PC is set to "Autorun", the CD-ROM menu is automatically opened. If not, you can start it by executing the file "CD_Menu_V5x.exe" which is located in the root directory of the CD-ROM. For instance, select "Start" -> "Run" and then enter "[X]:\CD_Menu_V5x.exe" (where [X] is the CD-ROM drive) to execute this file.
- Documentation 907 AC 1131 contains the complete hard- and software documentation for 907 AC 1131; - Documentation 907 FB 1131 contains the complete documentation for the field bus configurator 907 FB 1131; - Other Documentation contains the following documentation: - System Description Advant Controller AC31 - System Description ABB Procontic CS31 - Safety Manual Advant Controller 31-S (07 KT 93-S) - Safety Manual Advant Controller 31-S (07 KT 94-S) - Documentation for the MODBUS and RCOM/RCOM+ couplers -
1.2 The installation menu of 907 AC 1131 The installation menu of 907 AC 1131 is opened by clicking on the button "Installation 907 AC 1131 V5.x". The following menu page is displayed: Using the switch ‘Readme for Installation‘, this documentation is opened. By a single click on the switch ‘Overview of examples‘, a short documentation of all example projects is given. By a single click on the switch ‘Documentation of examples‘, an overview of the documentation of the example projects appears.
1.2.1 Installation sequence The following installation menus are available: 1. Step 1: Installation of the Programming Software 907 AC 1131 V5.x 2. Step 2: Installation of the Fieldbus Configurator 907 FB 1131 3. Step 3: Installation of the OPC server 4. Step 4: Installation of the ENI server 5. Option 1: Installation of the PCI Driver for the slot PLC 07 SL 97 (only Win NT) 6. Option 2: Installation of the Communication Drivers for Win NT/2000/XP 7.
1.2.2 Installing the programming software 907 AC 1131 The installation setup is started by clicking on the button "Step 1: Installation Programming Software 907 AC 1131 V5.x". Follow the instructions given in the setup. Prior to the installation, a PC system check is carried out. The results are displayed in message boxes. If an update is necessary for system files, this is reported. For certain system updates, administrative rights are required.
Caution: If the programming via ARCNET shall be used, the ARCNET card must be installed first. The installation of the ARCNET driver is not performed automatically and is described in the chapter "ARCNET card installation". From version V4.3 on, the ARCNET drivers are no longer copied to the hard disk. The drivers are included on the CD-ROM in the directory [X]:\CD_Menu\Dateien_V5x\ARCNET (refer to chapter "ARCNET card installation").
1.2.3 Installing the field bus configurator 907 FB 1131 The installation setup is started by clicking on the button "Step 2: Installation Fieldbus Configurator 907 FB 1131". Follow the instructions given in the setup. Caution: For the installation of the field bus configurator you must have administrative rights.
1.2.4 Installing the OPC server The installation setup is started by clicking on the button "Step 3: Installation OPC server". Follow the instructions given in the setup. By default, the OPC server is installed to the directory: C:\Programs\AC1131\OPC or C:\Program Files\AC1131\OPC All necessary files of the OPC server are installed and registered. For the communication of the OPC server with the AC31 basic units, the communication drivers of the programming software 907 AC 1131 are required.
1.2.5 Installing the ENI server The ENI server is available for the operating systems WinNT4.0 (SP3 or higher), Windows 2000 and Windows XP. For Win 98 SE, there is no ENI server available. The installation is started by clicking on the button "Step 4: Installation of the ENI server". Caution: For the installation of the ENI server you must have administrative rights. Please follow the instructions given by the SETUP. During the installation, the PC must be restarted. Leave the CD in its drive.
1.2.6 Installing the PCI driver for the slot PLC 07 SL 97 Installation of the PCI driver for WinNT4.0 SP3-SP6: The PCI driver is installed by clicking on the button "Opt. 1: Installation PCI Driver for the slot PLC 07 SL 97 (only Win NT)". Caution: For the installation of the PCI driver you must have administrative rights. The PCI driver SSSDRV.SYS is copied to the system directory, e.g. C:\WINNT\SYSTEM32\DRIVERS.
Installation of the PCI driver under Windows 2000/XP: As of version V5.x of the programming software 907 AC 1131, a new PCI driver exists for Windows 2000 / XP. After mounting the slot PLC 07 SL 97 into the PC, the new hardware is detected during the booting process (if PnP is active).
1.2.7 Installing the communication drivers (gateway and dlls) The communication drivers are included on the CD-ROM in the directory [X]:\CD_Menue\Dateien_V5x\Gateway An overview of the files belonging to the communication drivers can be found in the file: Gateway_Vxx.bmp During the installation of the programming software 907 AC 1131, the files are copied to the system directory, e.g. C:\WINNT\SYSTEM32 for Win NT / Win 2000 or C:\WINDOWS\SYSTEM for Win 98 SE and then registered in the registry.
1.3 Uninstalling the software 1.3.1 Uninstalling the programming software 907 AC 1131 Before you can uninstall the 907 AC 1131 software you must close the software and the gateway. In order to close the gateway, click with the right mouse button on the 907 AC 1131 icon in the status bar of the operating system and select "Exit".
2 2.1 The files of the programming software 907 AC 1131 Overview of files In addition to the files which are packed in the setup (directory: [x]\CD_Menu\Install_AC1131), all files of the programming software 907 AC 1131 V5.
2.2 Example projects for the programming software 907 AC 1131 All example projects for the programming software 907 AC 1131 are installed together with the software. In addition, they are included in an unpacked form on the CD-ROM in the directory [X]:\CD_Menue\Dateien_V5x\Projekte During the software installation, the same directory structure is created for the example projects: Subdirectories Contents ..\Projekte\Beispiele_S40 Example projects for series 40..50 ..
3 3.1 Notes regarding the configuration of the serial PC interface Configuring the serial interface for Windows NT (V4.0 onwards) If the message "Communication error, logging out" is displayed when logging in via the serial interface, please check the connection between PLC and PC and the communication parameters in the menu "Online" / "Communication Parameters". If the connecting cables and the communication parameters are ok, please check the following settings for the serial interface.
3.2 Configuring the serial interface for Windows 2000 If the message "Communication error, logging out" is displayed when logging in via the serial interface, please check the connection between PLC and PC and the communication parameters in the menu "Online" / "Communication Parameters". If the connecting cables and the communication parameters are ok, please check the following settings for the serial interface.
• Select "Start" => "Settings" => "Control Panel" => "System". In the "Hardware" tab of the "System Properties" dialog select "Device Manager" and then double click on "Ports" => "Communications Ports (COM1)". In the tab "General": -> Device Status = This device is working properly. -> Device Usage = Use this device (enable).
3.3 Configuring the serial interface for Windows 98 SE If the message "Communication error, logging out" is displayed when logging in via the serial interface, please check the connection between PLC and PC and the communication parameters in the menu "Online" / "Communication Parameters". If the connecting cables and the communication parameters are ok, please check the following settings for the serial interface.
4 ARCNET card installation 4.1 Overview of supported ARCNET cards The following ARCNET cards are available for the programming of series 90 PLCs in the integrated ARCNET coupler. ARCNET card SH FARC E3 (K) (with COM20022) SH ARC PCI Bus type ISA PCI SH ARC PCMCIA with SH KOAX-PCMCIA PCMCIA Operating system Driver file ) ( * on SoHard website) Win NT V4.0 *) Win 98 SE *) Win2000/XP *) Win NT V4.0 *) Win 98 SE *) Win2000/XP *) Win NT V4.
4.2 Installing ARCNET cards on Windows NT (V4.0 onwards) 4.2.1 SH ARC PCI - ARCNET card for PCI bus on WinNT Driver files: Internet: WNT_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\WinNT\farc.sys WNT_RAW_DRIVER_V0517.zip Driver after installation: ..\WINNT\system32\drivers\farc0.sys Installing the card: Note: The ARCNET card driver will only work, if a network is installed. If no network adapter is installed, the software for the "MS Loopback Adapter" can be installed.
Removing the card: Proceed as follows to remove the ARCNET card: 1. Select "Start" => "Settings" => "Control Panel" => "Network". 2. Select "Adapter" and then select the network adapter card which is to be removed. 3. Select "Delete". 4. Shut down the operating system of the PC and then switch it off. 5. Remove the card and restart your PC. Tips and tricks: The following notes should help you, if the communication does not work properly after the installation. 1.
4.2.2 SH ARC PCMCIA - ARCNET PCMCIA card on WinNT Driver files: Internet: WNT_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\WinNT\farc.sys WNT_RAW_DRIVER_V0517.zip Driver after installation: ..\WINNT\system32\drivers\farc0.sys Installing the card: Note: The ARCNET card driver will only work, if a network is installed. If no network adapter is installed, the software for the "MS Loopback Adapter" can be installed. Proceed as follows to install the ARCNET card: 1.
13. Confirm with "Ready" and "Close" and answer the request whether the PC shall be restarted with "Yes". Removing the card: Proceed as follows to remove the ARCNET card: 1. Select "Start" => "Settings" => "Control Panel" => "Network". 2. Select "Adapter" and then select the network adapter card which is to be removed. 3. Select "Delete". 4. Shut down the operating system of the PC and then switch it off. 5. Remove the card and restart your PC.
4.2.3 SH FARC E3 (K) - ARCNET card for ISA bus on WinNT Driver files: Internet: WNT_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\WinNT\farc.sys WNT_RAW_DRIVER_V0517.zip Driver after installation: ..\WINNT\system32\drivers\farc0.sys Installing the card: Note: The ARCNET card driver will only work, if a network is installed. If no network adapter is installed, the software for the "MS Loopback Adapter" can be installed. Proceed as follows to install the ARCNET card: 1.
12. Enter the following when the bus slot is requested: Type: ISA Bus number: 0 13. Enter the following for the card properties: Controller: COM20022 DriverAccess: FARC IRQ: Free IRQ determined in step 2 I/O Address: Free I/O range determined in step 2 14. Confirm with "Ready" and "Close" and answer the request whether the PC shall be restarted with "Yes". Removing the card: Proceed as follows to remove the ARCNET card: 1. Select "Start" => "Settings" => "Control Panel" => "Network". 2.
4.2.4 SH FARC E3 (with COM20020) - ARCNET card for ISA bus on WinNT Note: This card is no longer available! Driver files: CD V5.x: ..\CD_Menue\Dateien_V5x\ARCNET\ARCNET_ALT\ARCNET_NT\Treiber\farc.sys Driver: ..\WINNT\system32\drivers\farc.sys (V4.xx) Installing the card: Note: The ARCNET card driver will only work, if a network is installed. If no network adapter is installed, the software for the "MS Loopback Adapter" can be installed. Proceed as follows to install the ARCNET card: 1.
12. The following settings ("Properties") match with the factory settings. - Interrupt: IRQ 10 (or IRQ determined in step 2) - IO Address: 120 hex (288 decimal) (or the range determined in step 2) - Mem. Address: 0 - Controller: COM20020 - Driver: FARC - License number: ABB number: 34687-2-304-2710-0105877 (or request own number from SoHard) Tips and tricks: The following notes should help you, if the communication does not work properly after the installation. 1.
4.2.5 PCM 20 E - ARCNET PCMCIA card on WinNT (without further PCMCIA cards) Note: This card is no longer available! Driver files: CD V5.x: ..\CD_Menue\Dateien_V5x\ARCNET\ARCNET_ALT\ARCNET_NT\Treiber\farc.sys Driver: ..\WINNT\system32\drivers\farc.sys (V4.xx) Installing the card: Note: The ARCNET card driver will only work, if a network is installed. If no network adapter is installed, the software for the "MS Loopback Adapter" can be installed.
Restart NT to apply the settings. After starting select: "Settings" => "Control Panel" => "PC Card (PCMCIA)". In "Socket State" => "Properties" => "Resources" the parameters should be set as follows: - Interrupt Request: 10 (Example) - I/O Range: 300-30F (Example) The values 10 and/or 300-30F are probably different in your system. Note down the values. It does not matter that it is displayed in "Socket State" => "Properties" => "Drivers" that no driver was installed for this device.
Uninstalling the ARCNET driver To uninstall the driver perform the following steps: 1. Select: "Start => Settings => Control Panel => Network" 2. Select: "Network Adapter" 3. Select the driver to be removed: "ARCNET ISA adapter (20020)" 4. Click on "Remove". 5. Reboot your computer.
4.2.6 PCM 20 E - ARCNET PCMCIA card on WinNT (with other PCMCIA cards) Note: This card is no longer available! Driver files: CD V5.x: ..\CD_Menue\Dateien_V5x\ARCNET\ARCNET_ALT\ARCNET_NT\Treiber\farc.sys Driver: ..\WINNT\system32\drivers\farc.sys (V4.xx) Installing the card: Note: The ARCNET card driver will only work, if a network is installed. If no network adapter is installed, the software for the "MS Loopback Adapter" can be installed. The installation is described for the Toshiba notebook T460CDX.
4. Now install the Farc driver performing the same procedure as for the ISA card (steps 1-5). For the bus type you must select "ISA", not PCI, PCMCIA, PnP or anything else. However, for the I/O address enter the I/O address assigned by NT (in the example above: 300 hex) and also the IRQ (in the example above: 10)! For the Mem memory area select 0, for the controller type select "COM20020" as you did for the ISA card, for the driver select FARC and enter your license number. 1.
4.3 Installing ARCNET cards on Win2000 / XP 4.3.1 SH ARC PCI - ARCNET card for PCI bus on Win2000 / XP Driver files: Internet: W2K_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\Win2000\farc.sys (sharcraw.inf) W2K_RAW_DRIVER_V0517.zip Driver after installation: ..\WINNT\system32\drivers\farcpci.sys Installing the card: Proceed as follows to install the ARCNET card: 1. If necessary, delete the existing old ARCNET driver (V4.xx).
Removing the card: Proceed as follows to remove the ARCNET card: 1. Select "Start => Settings => Control Panel => System => Hardware => Device Manager". 2. Select "SoHard ARCNET / SH ARC PCI (RAW)". 3. Select "Delete". 4. Shut down the operating system of the PC and then switch it off. 5. Remove the card and restart your PC. Tips and tricks: The following notes should help you, if the communication does not work properly after the installation. 1. The card SH ARC PCI requires PCI version V2.
4.3.2 SH ARC PCMCIA - ARCNET PCMCIA card on Win2000 / XP Driver files: Internet: W2K_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\Win2000\farc.sys (sharcraw.inf) W2K_RAW_DRIVER_V0517.zip Driver after installation: ..\WINNT\system32\drivers\farcpcmcia.sys Installing the card: Proceed as follows to install the ARCNET card: 1. If necessary, delete the existing old ARCNET driver (V4.xx).
Tips and tricks: The following notes should help you, if the communication does not work properly after the installation. 1. Verify that the IRQ and/or the I/O range are not assigned twice. To do so, select "Start => Settings => Control Panel => Network => Network Adapter => Resources". 2. Test program for the drivers: The program arcread.exe is delivered together with the drivers.
4.3.3 SH FARC E3 [K] - ARCNET card for ISA bus on Win2000 / XP Driver files: Internet: W2K_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\Win2000\farc.sys W2K_RAW_DRIVER_V0517.zip Driver after installation: ..\WINNT\system32\drivers\farc0.sys Installing the card: Proceed as follows to install the ARCNET card: 1. If necessary, delete the existing old ARCNET driver (V4.xx).
13. Select "A:\tsharcraw.inf" and confirm with "OK". The driver is installed. 14. Enter the following for the card properties: Controller: COM20022 DriverAccess: FARC (is entered automatically) IRQ: Free IRQ determined in step 2 I/O Address: Free I/O range determined in step 2 15. Confirm with "Ready" and "Close" and answer the request whether the PC shall be restarted with "Yes". Removing the card: Proceed as follows to remove the ARCNET card: 1.
4.4 Installing ARCNET cards on Win98 SE 4.4.1 SH ARC PCI - ARCNET card for PCI bus on Win98 SE Driver files: Internet: W98_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\Win98\farc.sys W98_RAW_DRIVER_V0516.zip Driver after installation: ..\Windows\system32\drivers\farcpci.sys Installing the card: Proceed as follows to install the ARCNET card: 1. If necessary, delete the existing old ARCNET driver (V4.xx).
Removing the card: Proceed as follows to remove the ARCNET card: 1. Select "Start => Settings => Control Panel => System => Device Manager". 2. Select "SoHard ARCNET / SH ARC PCI (RAW)". 3. Select "Delete". 4. Shut down the operating system of the PC and then switch it off. 5. Remove the card and restart your PC. Tips and tricks: The following notes should help you, if the communication does not work properly after the installation. 1. The card SH ARC PCI requires PCI version V2.10 and hardware level V1.1.
4.4.2 SH ARC PCMCIA - ARCNET PCMCIA card on Win98 SE Driver files: Internet: W98_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\Win98\farc.sys W98_RAW_DRIVER_V0516.zip Driver after installation: ..\Windows\system32\drivers\farcpcm.sys Installing the card: Proceed as follows to install the ARCNET card: 1. If necessary, delete the existing old ARCNET driver (V4.xx).
Tips and tricks: The following notes should help you, if the communication does not work properly after the installation. 1. Test program for the drivers: The program arcread.exe is delivered together with the drivers. Start it from a DOS shell using the following command: arcread farc 254 The driver is started or a corresponding error message is displayed! 2. If the error message ..59 (E_FARC_NO_NEXTID) is displayed, the selected interrupt is unsuccessful.
4.4.3 SH FARC E3 [K] - ARCNET card for ISA bus on Win98 SE Driver files: Internet: W98_RAW_DRIVER_V05xx.zip CD V5.x: packed: ..\CD_Menue\Dateien_V5x\ARCNET\Win98\farc.sys W98_RAW_DRIVER_V0516.zip Driver after installation: ..\Windows\system32\drivers\farc0.sys Installing the card: Proceed as follows to install the ARCNET card: 1. If necessary, delete the existing old ARCNET driver (V4.xx).
14. The settings selected by Win98 are displayed, e.g.: I/O range: 0110-011F Interrupt: 10 Click on "Next". 15. Modify the settings according to the settings of the card. For this, select "Start => Settings => Control Panel => System => Device Manager" and then select the entry "SoHard ARCNET=>SH FARCxx (RAW)". Enter the IRQ and the I/O range at "Properties" => "Resources". The "DriverAccessName" is already entered correctly as "FARC". 16.
4.4.4 SH FARC E3 (with COM20020) - ARCNET card for ISA bus on Win98 SE Note: This card is no longer available! Driver files: CD V5.x: ..\CD_Menue\Dateien_V5x\ARCNET\ARCNET_ALT\ARCNET_95_98\Treiber Driver: FARC20.VXD (and ARCNET32.DLL for Win98 SE !) Installing the card: For programming a PLC via ARCNET using Win95/98 SE, SoHard's FARC E3 card (ISA card) and FARC20.VXD driver can be used. On the card, set the I/O range and the interrupt IRQ according to the enclosed documentation.
3. Reboot your computer. Using the provided DOS test programs you can test in the MS-DOS shell whether the communication with another ARCNET subscriber (e.g. a PLC) works properly. Note: During the installation of the 907 AC 1131 software, the file ARCNET32.DLL is copied to the operating system directory "WinNT/System32" for WinNT 4.0 and "Windows/System" for Win95/98 SE. When installing the ARCNET driver for Win95/98 SE after the programming software, using INSTALL.
4.4.5 PCM 20 E - ARCNET PCMCIA card on Win98 SE Note: This card is no longer available! Driver files: CD V5.x: ..\CD_Menue\Dateien_V5x\ARCNET\ARCNET_ALT\ARCNET_95_98\Treiber Driver: FARC20.VXD (and ARCNET32.DLL for Win98 SE !) Installing the card: For programming the PLC via ARCNET using a notebook Contemporary Control's PCMCIAARCNET adapter PCM 20E can be used. SoHard's Win95/98 SE (ISA card!!) driver FARC20.VXD is used because Contemporary Control does not provide a driver.
8. If you need other settings for I/O range or IRQ than the standard settings, copy the file FARC20.REG from the directory and edit this file [X]:\CD_Menue\Dateien_V5x\ARCNET\ARCNET_ALT\AECNET_95_98\Treiber. Do not double click to open. This would already start the registration.
6 Installation 50 907 AC 1131/Issued: 08/03
Manual No.: 2CDC 120 061 M 0202 ABB STOTZ-KONTAKT Eppelheimer Straße 82 69123 Heidelberg Germany Telephone Telefax E-Mail Internet GmbH Postfach 101680 69006 Heidelberg Germany +49 6221 701-0 +49 6221 701-240 desst.helpline@de.abb.com http://www.abb.