User's Manual

1
Wall mounting Ceiling mounting
2
When not mounted When already mounted
3
1) Remove provided screws for installation.
2)
5
4
+ ~12-28 V AC
1
2
3
4
5
Common
Normally closed
48 V AC / DC
24 W / 55 VA
white
brown
green
yellow
grey
Normally open
- ~12-36 V DC
Side cable exit as shown on the left or
front cable exit as shown below
sensing the future
* The device must only be operated at a protective low voltage with safe electrical insulation. Product repairs must be performed solely by the manufacturer.
* Shut off all power going to the sensor before attempting any wiring procedures.
* Maintain a clean & safe environment when working in public areas.
* Constantly be aware of pedestrian traffic around the door area.
* Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
* Always check placement of all wiring and components before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
* Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
Safety instructions
Microwave motion detector for automatic pedestrian doors [ES with direction recognition] Questions? Call us at 800 - 252-1272, 8am - 5pm central standard time.
DO NOT LEAVE ANY PROBLEMS UNRESOLVED - NEVER SACRIFICE SAFETY FOR ANY REASON
Impulse
motion
1. Turn on power and allow detector
to self-tune
2. Stay outside the detection zone
for 5 seconds
Test the size and position of the
sensing eld
Open sensor with a screwdriver
Drill holes using template
Install sensor with provided screws
Connections
Testing of the settings
1