Preface Preface Thank you for selecting the GE006 Blood Glucose Monitoring System. This manual provides all the information you need to operate this product for accurate test results. Please read this entire manual before you start any testing. The GE006 Blood Glucose Monitoring System is a personal blood glucose monitoring system to be used for self-testing only. It is not recommended for multiple users. A healthcare professional should be contacted when Customer Service is not available.
Precaution Caution - Before using the GE006 Blood Glucose Monitoring System to test your blood glucose, please read all of the instructions and conduct all of the tests including the quality control test (Refer to page 37). - Please perform the quality control test regularly to make sure the test results are accurate. - The GE006 Blood Glucose Meter can only be used with GE006 Blood Glucose Test Strips. Other brands’ test strips should not be used under any circumstances.
Table of Contents Table of Contents About the GE006 Blood Glucose Monitoring System The GE006 Blood Glucose Monitoring System ..................................................................................................................... 8 The GE006 Blood Glucose Meter ................................................. ............................................................. .................................. 10 The GE006 Blood Glucose Test Strip ..................................................
The GE006 Blood Glucose Monitoring System Contents Your GE006 Blood Glucose Monitoring System consists of several items. Please identify each item, learn its name and how it is used. Below are the items included in your GE006 Blood Glucose Monitoring System: 1. Getting Started Guide * 2. User's Manual (includes Log Book, Warranty Card, Emergency Card ) * 3. GE006 Blood Glucose Test Strip Package Insert * 4. Rightest® Control Solution GC550 Package Insert * 5.
The GE006 Blood Glucose Meter The GE006 Blood Glucose Meter Test Strip Port Display Window Battery Cover Main Button ( ) Product name Meter Battery Meter Serial Number Left Button ( 10 ) Right Button ( ) 11
The GE006 Blood Glucose Meter The GE006 Blood Glucose Meter Indicates a test result stored in memory Indicates when to apply the blood sample Indicates a test result not included into the Average function of this meter Appears after you insert test strip into meter Indicates the average result Appears when an error occurs Indicates a control solution test result Current date under time mode or testing date under memory mode Unit of test result Warns when the operational temperature limit is exceed
The GE006 Blood Glucose Test Strip The GE006 Blood Glucose Test Strip The GE006 Blood Glucose Meter can only be used with GE006 Blood Glucose Test Strips and Rightest™ Control Solution GC550. The use of other test strips or control solutions can lead to incorrect results. Electrode Contacts Sample Port Apply blood/control solution here. Noble Metal Electrodes Electrochemical sensor View WIndow 14 Hold here to insert test strip into meter.
Meter Activation and Battery Change Meter Activation and Battery Change Your GE006 Blood Glucose Meter comes with two AAA, batteries installed. Two new batteries will provide power to perform approximately 800 tests under normal use with one data transfer. Press the main button or insert a strip to activate your meter. 2. Install the batteries. Be sure to 1. Turn the GE006 Blood Glucose 3. Slide the battery cover Meter over.
Setting Up Your Meter - Setting the Date, Time and Volume 1. Year setting With the year format blinking, press the Left or Right button until you see the current year. Press the Main button to confirm. Once the year is confirmed, the Month Setting will appear. 2. Month setting With the month blinking, press the Left or Right button until you see the current month. Press the Main button to confirm. Once the month is confirmed, the Day Setting will appear. 3.
Setting Up Your Meter - Setting the Date, Time and Volume 7. Volume Setting With the volume blinking, press the Left or Right button to turn the volume on or off. Press the Main button to confirm and finish the settings. 8. Setting the Unit of Measurement With milligrams per deciliter (mg/dL) or millimoles per liter (mmol/L) blinking, press the Left or Right button to switch. Then press the Main button to confirm it and finish the settings. 9.
Handling the GE006 Blood Glucose Test Strip Turning On/ Off the Bluetooth 1. Auto turn on the Bluetooth After leaving the Setting mode, the Bluetooth will turn on automatically and the " " symbol blinks on the screen. 2. Turn off the Bluetooth In Time mode, press and hold the Right or Left button for two seconds. The blinking " " symbol will switch to the “ “ symbol with a beep (If Volume is turned on). How to handle the GE006 Blood Glucose Test Strip. 1) Inserting the GE006 Blood Glucose Test Strip: 1.
Handling the GE006 Blood Glucose Test Strip Removing the GE006 Blood Glucose Test Strip: 1. Hold the GE006 Blood Glucose Test Strip as shown. Getting Ready for Testing 1 2. Rotate the GE006 Blood Glucose Test Strip counterclockwise and pull up simultaneously. 2 3. Take the GE006 Blood Glucose Test Strip out of the test strip port. Please follow your health care professional's direction and discard used strips properly.
Performing a Blood Glucose Test 1. Hold the depth adjustable cap in one hand and hold the base with the other hand. Bend the cap down. When a gap appears between the cap and base, pull the cap and base in opposite directions. Performing a Blood Glucose Test 1 2 3 4 5 6 2. Pull off the depth adjustable cap. 3. Insert a new disposable lancet firmly into lancet carrier. 4. Twist off and set aside the protective cover of the disposable lancet. 5. Replace the depth adjustable cap. 6.
Performing a Blood Glucose Test Performing a Blood Glucose Test 12. A blood drop icon will appear on the display window and will be accompanied by a beep (if volume is turned on). Apply the blood sample within 2 minutes. 12 13 16 17 1 2 17. Hold the release button in one hand (see picture 17, step 1) and pull on the plunger with the other hand (see picture 17, step 2) to safely eject the used disposable lancet. 13. Place the lancing device against your fingertip and press the release button.
Setting Markers Performing a Blood Glucose Test CAUTION - Do not apply your blood drop to the sample port on the strip until you see the " " appear. The GE006 Blood Glucose Meter is performing an internal test and will display " " and “ " if you apply blood too soon. If this occurs, please repeat the test with a new test strip. - Record the opening date of a new test strip vial. Discard the vial of test strips 3 months after opening. - Always keep the metal contacts of the test strip port clean.
Alternative Site Testing Alternative site testing: palm or forearm blood sampling Alternative Site Testing Palm - To perform alternative site testing, install the clear cap for your Rightest™ GD500 Lancing Device. ( For detailed information, refer to the instruction manual for the Rightest™ GD500 Lancing Device. ) - To increase the blood flow, massage the intended puncture area of your palm or forearm for a few seconds.
View Window Appearance Understanding Test Results and Messages Make sure your blood sample covers the whole area of the view window to get an accurate test result. An insufficient blood sample will result in an error message ("Er4"). If this occurs, repeat the test with a new test strip. If your blood glucose result is unusually high or low, or if you question your test results, repeat the test with a new GE006 Blood Glucose Test Strip.
About Quality Control Testing Understanding Test Results and Messages The GE006 Blood Glucose Meter displays results between 10 and 600 mg/dL. If the test result is below 10 mg/dL , “ ” will appear on the screen. Please repeat your test with by a new test strip. If you still get a “ ” result, contact your healthcare professional. If the test result is above 600 mg/dL, “ ” will appear on the screen. Please repeat your test again with a new test strip.
About Quality Control Testing When should a Quality Control Test Be Performed ? - To ensure that your GE006 Blood Glucose Meter and GE006 Blood Glucose Test Strip are working properly. - To confirm that you are following the correct testing procedures. - To prepare for your initial blood glucose test. - To check the GE006 Blood Glucose Test Strip when you open a new vial of strips. - To check your GE006 Blood Glucose Meter after it has been dropped, damaged or exposed to liquids.
Performing a Quality Control Test Performing a Quality Control Test 1. Take one GE006 Blood Glucose Test Strip from the vial and close the vial cap immediately. 2. Insert the GE006 Blood Glucose Test Strip horizontally (not vertically) with the colored view window facing up into the test strip port. 3. While the blood drop icon is flashing on the display window, press and hold the Main button for at least 3 seconds until the " " symbol appears. 4.
Recalling Test Results Understanding Control Test Results Your control solution test results should fall within the control solution range. If the results are within the range, the GE006 Blood Glucose Monitoring System is working correctly. Control Solution Range Level 2 88~120 mg/dL To recall your test memory, start the meter without a test strip inserted.
Recalling Test Results The GE006 Blood Glucose meter provides several average test results. View the 1-day, 7-days, 14-days, 30-days, 60-days and 90-days average test results for better blood glucose monitoring. 1. Press the Main button to switch the screen to Average Mode. 2. On the average screen, use either the Left or Right button to view 1-day, 7-days, 14-days, 30-days, 60-days or 90-days averages. 3. The number shown in the lower right hand corner indicates how many test results have been calculated.
Caring for Your Meter Maintenance Keep your meter and test strip free of dust, water or any other liquid. Store the meter in the carrying case when not in use. If your meter is dropped or damaged, perform a quality control test with the control solution before performing a blood glucose test. Cleaning Meter Clean the outside of the meter with a damp cloth and mild soap/detergent. Do not get the test strip port wet.
Cleaning and Disinfecting Procedures Cleaning and Disinfecting Procedures NOTE - Clean and disinfect the outside of the device only. Do not remove battery cover when cleaning and disinfecting. To clean the meter: 1. Throughly wipe the entire surface of the meter with disinfecting wipes listed above to clean any possible dirt, dust, blood and other body fluids. To disinfect the meter: 2. Take another disinfecting wipe and wipe the meter thoroughly.
Cleaning and Disinfecting Procedures CAUTION - Users should wash their hands thoroughly with soap and water after handling the meter, lancing device or test strips. - Please examine your LCD screen, test strip port, buttons and surface of your meter and lancing device after cleaning and disinfecting cycles. Stop using the meter and/or lancing device if any of the following occur: - Thin, sliver streaks appear on the screen, - The screen becomes cracked, soft, dissolved, brittle or swollen.
Error Messages and Troubleshooting Battery Error 1. The " " symbol blinks when the battery power is low. Please change the battery as soon as possible. You can still test. 2. The " " and " “ symbols blink when the battery is too low. Meter cannot test. Please change the battery immediately. Strip Error 1. When the test strip is inserted incorrectly, the meter will beep 4 times while the “ ” symbol flashes. Do not apply a sample on the test strip.
Error Messages and Troubleshooting CAUTION A blood sample should ONLY be applied to the test strip after the test strip has been inserted correctly and the Meter's screen is showing the image of the test strip and a blood drop flashing symbol. If the blood drop flashing symbol is NOT showing on the screen, do not apply a sample to the test strip. Please re-insert the unused test strip correctly.
Real Time Synchronize Real Time Synchronize The GE006 Blood Glucose Meter can be used with the HeartSquare App, a mobile application. After pairing the GE006 Blood Glucose Meter with the mobile phone by Bluetooth, the HeartSquare App will automatically detect any activities on the GE006 Blood Glucose Meter.
FEDERAL COMMUNICATIONS COMMISION (FCC) STATEMENT 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user's authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
NCC警語 Specification A) 根據NCC低功率電波輻射性電機管理辦法第十條規定: 60 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅 自變更頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象 時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信 法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫 療用電波輻射性電機設備之干擾。 Measurement Technology Oxidase Electrochemical Sensor Sample Capillary whole blood Minimum Sample Volume 0.
Specification Warranty Bionime Corporation warrants that this product will be free from defects in materials and workmanship for five years from the date of purchase. Hematocrit 30 - 60% Power Supply Two AAA Batteries Battery Life Approximately 800 tests, each test with one data transfer This warranty applies only to the original purchaser of the GE006 Blood Glucose Monitoring System. 85mm x 57mm x 22.5 mm Please complete and return the enclosed warranty card. Meter Weight 81.
Customer Service Expected Glucose Values Without Diabetes Please review all of the instructions to make sure you are performing the steps correctly. If you have any questions or concerns, please contact your Bionime authorized representative. We will make every effort to provide assistance and solutions for you.
Component Manufacturer Information Blood Glucose Meter, Test Strip, Control Solution Manufacturer: Bionime Corporation No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Product complies with In Vitro Diagnostic Medical Device Directive 98/79/EC. ( CE0197 ) EC-Rep: Bionime GmbH, Tramstrasse 16, 9442 Berneck / Switzerland E-mail: info@bionime.ch Lancing Device Manufacturer: Bionime Corporation No. 100, Sec. 2, Daqing St., South Dist.
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 68 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 70 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 72 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 74 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 76 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 78 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Log Book DATE Breakfast Lunch Dinner Bedtime Other Comments 80 Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Log Book M T W T F S S DATE Breakfast Lunch Dinner Bedtime Other M T W T F S S Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Blood Glucose Insulin/ Medication Comm
Warranty Card Name Warranty Card Tel Distributor name and address PLACE Address Serial No STAMP Distributor name and address Model HERE Date of purchase (Please present this card for replacement purpose) Limited warranty: 1.
Emergency Card Warranty Card Thank you for purchasing our product. Please complete and mail this warranty card within 30 days of purchase of your GE006 Blood Glucose Monitoring System. Name Male/Female Date of Birth Address City Country Postal Code EMERGENCY CARD GE006 Blood Glucose Monitoring System Phone Number Healthcare Professional Who Recommended City Country Store/Pharmacy Name Where Purchased City Country Date of Purchase Model No: Serial/Lot No. • User Name: • User Phone No.