BB1000 OWNER’S MANUAL
TABLE OF CONTENTS PRODUCT INFORMATION Important Safeguards & Cautions....................4 Cautions Before Installation................................6 Main Unit & Parts......................................................8 PRODUCT INSTALLATION Installation....................................................................9 How To Detach the Unit.......................................12 Testing & Seat Bumpers.......................................13 PRODUCT OPERATION Operation..........................
IMPORTANT SAFEGUARDS & CAUTIONS READ ALL OPERATING INSTRUCTIONS BEFORE INSTALLATION • This product should be installed according to this manual. • Read this manual carefully and install properly. • Do not attempt to service this appliance yourself. • Doing so will void the warranty. READ ALL INSTRUCTIONS BEFORE USING • Do not open the product to repair or remodel. Only qualified service personnel should service this product. Do not use attachments not recommended by the manufacturer.
IMPORTANT SAFEGUARDS & CAUTIONS (CONT.) CAUTIONS BEFORE INSTALLATION WIRING REQUIREMENT This product MUST be plugged into a regular voltage Grounded GFCI outlet (North America 120V ac, 60Hz/ Europe 220-240V ~, 50/60Hz). The rated power consumption is 660W/600-700W. In locations where only a standard two-prong outlet is available, it is the responsibility of the user to install a grounded three-prong outlet. Using a higher voltage is dangerous and may result in a fire or other accident.
CAUTIONS BEFORE INSTALLATION (CONT.) OPTIONAL GROUNDING INSTRUCTIONS DANGER IMPROPER USE OF GROUNDING CAN RESULT IN A RISK OF ELECTRIC SHOCK. ELECTRIC WIRING HAS TO BE DONE IN ACCORDANCE WITH ALL LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODES. The use of an extension cord is not recommended or advised.
MAIN UNIT & PARTS INSTALLATION CAUTION BEFORE INSTALLATION • Do not plug in before installation • If you need an electric power system or extension, please consult a qualified electrician. • Please contact out service center at 847.458.2334 when you want to reinstall the bidet product (move or replacement). 1. Turn off the water. • Shut off the water supply valve. Drain the toilet tank completely. Then remove the existing fill valve water supply hose. 10 2. Remove the existing seat and lid.
INSTALLATION (CONT.) 3. Connect the T-valve. 4. Connect the water supply hose to the assembled T-valve. 7. Assembly. 8. Bidet Hose Assembly. Water supply hose 1/2"conversionnut • Remove existing supply hose connected to the toilet tank. Make sure not to damage the water supply hose. • Install the T-valve at the thread from the tank. 5. Installation Catch Plate. • Remove the existing supply hose from the toilet tank • If your shut off valve is 1/2” size, use supplied 1/2” conversion nut as shown.
INSTALLATION (CONT.) 9. Deodorizer Installation HOW TO DETACH THE UNIT DO NOT TURN UNIT UPSIDE DOWN. • Disconnect the power plug. • Close water supply shut-off valve. • Drain water from bidet seat using drainage as illustrated. • Insert the deodorant cartridge into the unit. • Remove bidet seat from the toilet as illustrated. Drainage is also release button from catch plate. • Follow the below photos to change the deodorant. • Insert the new deodorant case into the unit. 10.
TESTING & SEAT BUMPERS OPERATION Adjust the water pressure and warm air dryer temperature. Adjust the oscillation function and nozzle position (5 levels). Adjust the water and seat temperature (4 levels). • Plug the power cord into the outlet, and then the water tank will be filled with water in 2 minutes. • After installing your bidet attachment, check to see if there is a gap between the toilet base and toilet seat. • Check all the functions.
OPERATION (CONT.) OPERATION Sit Down On the Seat • When you sit down on the seat, the ORANGE LED lamp on the control panel will light up. • When the digital sensor on the seat is activated, the operation LED window on the main unit will light “Occupied sensor” and simultaneously, the deodorizer fan will start to work. STOP • Press this button to stop all operation. TURBO WASH • Press “Turbo Wash,” the nozzle spray is more or focused to produce the effect of strong wash, to help stimulate bowel movement.
OPERATION (CONT.) TURBO WASH • Press “Turbo Wash” continuously for 3 to 5 seconds. Automatically, the water nozzle comes out and sprays a warm stream of water to the posterior center of the rectum. • If necessary, adjust “Position” of water stream with the • Press “Water Pressure High & Low button” pressure to your desired comfort. / / WARM WATER TEMPERATURE AND SEAT TEMPERATURE ADJUSTMENT • The temperature of water and seat are adjustable to the desired level by pressing the “WATER” and “SEAT” button.
OPERATION (CONT.) Auto-Setting of Oscillation Feature AUTO SETTING OF MASSAGE FEATURE You can set this function to automatically oscillate whenever the seat is occupied and the Posterior or Feminine washes are in operation. You can set this function to automatically pulsate whenever the seat is occupied and the Posterior or Feminine washes are in operation. • Do not sit on the product. • Do not sit on the product • Press the “MOVE” button for 3 seconds or until you hear a single chime.
OPERATION (CONT.) MAINTENANCE NOZZLE CLEANING (Automatically) CLEANING THE NOZZLE • This product has an automatic nozzle self-cleaning function that cleans the nozzle before and after each use. NOZZLE CLEANING (Manual) • Nozzle can be cleaned manually by pressing “Posterior Wash” button for 3 seconds without being occupied on the seat and the nozzle will come out without spraying water. After cleaning the nozzle, Press “Stop” button to return the nozzle to the stand-by mode.
MAINTENANCE CONT. WATER DRAINING CLEANING THE STRAINER If you do not intend to use this product for 14 days or longer, drain the water from the product’s warm water tank THIS PRODUCT WILL NOT OPERATE PROPERLY IF THE STRAINER IS CLOGGED. PLEASE CLEAN THE STRAINER REGULARLY. • Disconnect the power plug. • Close the water shut of valve • Press the drain lever until the water is completely drained from the water tank. • To re-supply water after draining, open the water shut off valve.
TROUBLESHOOTING GUIDE PROBLEM The washing water does not spray The unit is not operating. Water is leaking. 28 POSSIBLE CAUSE • The water tank is not filled. • The shutoff valve is closed. POSSIBLE SOLUTION • Wait about one minute. Press the desired washing button once again. • Turn the shutoff valve to open. • Freezing inside the main unit or the water supply pipe. • Heat the room (for about two hours). Operating the unit while parts are frozen will cause a malfunction.
SPECIFICATIONS SPECIFICATION BB-800 SPECIFICATION Power Rating Australia or Europe: 240-240V~, 50/60Hz, 600-700W Turbo Function Inlet water temperature 3°C~35°C (37.4°F ~ 95°F) America or Canada: 120Vac, 60Hz, 660W Ambient Temperature 3°C ~ 40°C (37.4°F ~ 104°F) Type Direct Inlet flow type Dimension 0.04 ~ 0.74MPa (04 ~ 7.5 kgf/cm) ELONGATED (Control) ROUND (Control) Water inlet pressure W:495mm (19.4in) W: 495mm (19.4in) L:525mm (20.6in) L: 493mm (19.4in) H: 185mm (7.
WARRANTY THREE YEAR LIMITED WARRANTY • 100% Coverage of all parts and labor for the entire product for the first year from original date of purchase • 75% Coverage of all parts for the entire product for the second year from the original date of purchase • 50% Coverage of all parts and labor for the entire product or the third year from original date of purchase.
WARRANTY INFORMATION TO THE USER (For America) WARNING This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Thank You Technical Support/Customer Service 7900 S Route 31 Crystal Lake, IL 60014 T: 847.458.2334 U.S. TOLL FREE: 877.339.5214 support@biobidet.com www.biobidet.