Audia® AudiaFUSION Manual Biamp Systems | 9300 S.W. Gemini Drive | Beaverton, OR | 97008 | USA | +1.503.641.7287 | www.biamp.
IMPORTANT SAFETY INSTRUCTIONS
table of contents audiafusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
audiafusion alarm activity signal 1 status signal 2 ais power AudiaFUSION is the newest member of the Audia® family, bringing together open-architecture DSP, Multi-Channel Amplifier technology, and device- and load-monitoring capabilities. AudiaFUSION features an 8-channel modular amplifier, 16x16 I/O via CobraNet® and DSP with support for channel-to-channel and device-to-device failover.
audiafusion front panel Setup and Use The Audia software provides the interface for configuring and programming AudiaFUSION. The information supplied by this manual relates to hardware installation, physical connections, and device and channel failover concerns. For more details on software setup, please consult the Audia software Help File. Figure 1.
audiafusion front panel Signal 1 is a tri-color LED that indicates audio signal presence on the channel. Green indicates that the audio signal level is between -50 dBFS and -3 dBFS, amber indicates a signal level between -3 dBFS and 0 dBFS, and red indicates clipping. Signal 2 has no function at this time and is in place for possible future use. Chassis Indicators Alarm is a two-color LED that illuminates when a chassis fault has occurred.
Audia FUSION chassis composite (Pantone Black) 6/30/09 BG audiafusion rear panel Figure 3.
audiafusion rear panel Please note that CobraNet limits network extensions to seven hops (one-way transmissions) within a network. The primary and secondary CobraNet ports are redundant. Each connector provides two LEDs that indicate Ethernet link and network activity (see table below). Table 1. CobraNet interface status LEDs Left LED Right LED Description None None No data connectivity. . Green None Link established.
audiafusion rear panel Amplifier-to-Amplifier Failover AudiaFUSION supports one-to-one automatic device failover in case of fault. Failover is triggered by one of the following conditions: • Chassis alarm • Channel alarm • Loss of power • Loss of CobraNet link • Loss of Logic I/O Only alarms (e.g., heat sink alarm and channel failure alarm) trigger the failover mechanism. Warnings indicate abnormal system conditions that do not immediately impair audio and do not trigger the failover mechanism.
audiafusion rear panel Channel-to-Channel Failover In addition to entire amplifier failover, AudiaFUSION supports channel-to-channel failover, which is triggered by one of the following conditions: • Heat Sink alarm • Short Circuit alarm* • Channel Failure alarm The wire failover link cable is not required when wiring channel-to-channel failover.
audiafusion specifications AudiaFUSION SPECIFICATIONS Inputs: 20 bits, 48 kHz, supported CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms software configurable Connection: RJ45 with shielded Ethernet cable (Cat5, Cat5e, Cat6, or Cat7) Overall Dimensions: Height: Width: Depth: Weight: Chassis: AM-600 card: Compliance: Environment: Ambient Operating Temperature Range: Ambient intake humidity: Altitude: 5.25 inches (133mm) 19 inches (483mm) 17.25 inches (438mm) 32-95 degrees F (0 – 35° C) 50 lbs. (22.
audiafusion specifications AudiaFUSION Block Diagram NETWORK MODULE AMPLIFIER CARD SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 DSP DSP CLASS D AMPLIFIER DC DETECTION TEMPERATURE IMPEDANCE MONITORING CobraNet Audio CobraNet Ethernet Control 10/100 ETHERNET Serial I/O RS-232 Logic I/O LOGIC uC Display FAN CONTROL FAN 1 FAN 2 11 I V
audiafusion specifications AudiaFUSION 115 VAC current draw and heat output To determine the AC line current draw and heat output for the configuration, start by finding the total power for the configured AudiaFUSION chassis. Then refer to the column that describes the type of audio levels the amplifier will be producing. If your configuration uses more amplifier modules than the number shown, add 0.1 amps and 37 BTU for each additional module in the chassis.
audiafusion warranty BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below.
DoC DSPA201003 EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. Any alterations to the product not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration.
compliance 15
IMPORTANT SAFETY INSTRUCTIONS 16
IMPORTANT SAFETY INSTRUCTIONS 17
IMPORTANT SAFETY INSTRUCTIONS 18