User's Manual

MCW-D 50 – Control Unit
36
3.2.5 How to switch the Control Unit on/off
Switch on the MCW-D 50 with the On/Off-switch on the rear.
During the first 30 seconds the MCW-D 50 control unit is started, the Power LED and the Channel LEDs are flashing red and an
operation is not yet possible. If the MCW-D 50 control unit is connected to a network via the LAN connection , the MCW-D 50
control unit will be ready for operation after approx. 20 seconds.
The Power LED on the front will illuminate green, when the control unit is ready for operation.
CAUTION: Always turn off the power when making input or output connections.
Rear Front
3.2.6 Channel Indication
Depending on the configuration of the MCW-D 50 control unit 3 or more channel-LEDs will illuminate green (standard: 3 channels).
3.2.7 Rack Mounting
When mounting the MCW-D 50 control unit into a 19"-rack housing leave 1 HU for a ventilation panel above and under the
control unit.
Make sure that the mains switch, mains plug and all connection on the rear of the device are easily accessible.
3.2.8 Volume Control
The volume of the microphone units is controlled with the virtual volume control of the MCW-D 50 Conference Software.
Important:
If the MCW-D 50 control unit is equipped with more than one module, but there are not more than 3 LEDs illuminated, please
check if individual modules have been deactivated with the MCW-D 50 Conference Software.
16
1
1 4
7
4
16
1
4