User's Manual

MCW-D 50 – Control Unit
34
3.2 Setting up
3.2.1 Where to place the Control Unit
If you do not use remote antennae*, place the MCW-D 50 control unit in the room where the meeting takes place. If you use remote
antennae*, place them in the conference room.
Do not place the MCW-D 50 control unit near digitally controlled equipment.
Do not use the control unit outside.
*Important note for the USA and Japan: At present only the use of the CA 2413 remote antenna is permitted.
RS 232 port for the connection of PC or media control system (9-pin Sub-D).
Use a null modem or crossover cable (female - female).
LAN network connection for PC
Control LED for antenna powering 5 V DC (green = normal DC ; flashing red rapidly = short circuit)
Switch -10 dB / +15 dB for unbalanced input (RCA)
Input, RCA, unbalanced, for the connection of external devices such as CD players (L + R)
Output - master output, RCA, unbalanced, for the connection of external devices such as mixing consoles,
sound contracting systems or recorders (L + R)
Level control for Output - master output, RCA
Switch -10 dB / +15 dB for balanced input (XLR)
Input, 3-pin XLR female, balanced, for the connection of external sound sources (+6 dBm)
Output - master output, 3-pin XLR male, balanced, for the connection of external devices such as mixing consoles,
or sound contracting systems
ON/OFF-switch
Fuse
Mains supply
Connection for receiving antennae
Connection for transmitting antenna
6
7
8
9
10
10
10
11
11
12
13
14
14
15
16
17
18
19
20
Rear
6 7
11 12 13 14 15 16 17 18
192019
98