OWNER’S MANUAL
CONTENTS pg 003 PRE-SETUP CHECK LIST pg 008 INSTALLATION pg 010 SET-UP INSTRUCTION IN WINTER pg 010 USING THE SPA pg 014 MAINTENANCE pg 018 DISASSEMBLY AND STORAGE pg 020 TROUBLESHOOTING pg 022 ERROR CODES pg 024 ycorp.com/s up twa po es .b help for rt Visit ww w IMPORTANT SAFETY INSTRUCTIONS WE SUGGEST NOT TO RETURN THE PRODUCT TO THE STORE QUESTIONS? PROBLEMS? MISSING PARTS? For FAQ, Manuals, Videos Or spare Parts, Please Visit bestwaycorp.
IMPORTANT SAFETY INSTRUCTIONS WARNING IMPORTANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS. To reduce the risk of injury, do not permit children to use this WARNING – product unless they are closely supervised at all times. A wire connector is provided on this unit to connect a minimum 8 AWG (8.
accurate thermometer since the tolerance of water temperature-regulating devices varies. d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning. e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa.
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
1. Take out the warning label from the accessory kit. 2. Carefully peel the warning label. 3. Affix the warning label. To order the warning label, please contact your local Bestway After Sales Service. SPA SUCTION FITTING INSTRUCTIONS When installing and using this equipment, basic safety precautions shall always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS READ, FOLLOW, AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS.
obstructions during installation of cover/grate and fasteners. • Remember to hand-check cover/grate for snugness to the sump/ frame after installation. 6. Before using the product, please check the integrity of the head of the suction fitting. If the product is broken, please do not use it. 7. All SOFAs shall be installed in accordance with the manufacturer’s installation instructions.
PRE-SETUP CHECK LIST PARTS CHECKS Please examine equipment before use. Notify Bestway® customer service of any damaged or missing parts at the time of purchase. Verify that the equipment components represent the model that you had intended to purchase. For reference please use the diagrams below. VANCOUVER AIRJET PLUS S100205 (60028) — 61" x 24" / 1.55 m x 60 cm 3-5 2-3ºF/h 1.0-1.5ºC/h 320 gal/h 1,211 L/h 0.48-0.
MILAN AIRJET PLUS S100205 (60029) — 77" x 28" / 1.96 m x 71 cm 4-6 2-3ºF/h 1-1.5ºC/h 320 gal/h 1,211 L/h 0.08Bar 1.2PSI 242 gal 916 L 2,103 Lb 954 kg 2 01 P05209 1 02 P05340 1 03 P05213 1 04 P03427 1 05 P05341 1 06 07 P05345 1 08 P05524 2 09 P00217 1 10 P05320 6 11 / 2 12 P61726ASS18 1 14 P05346 1 15 P6609ASS16 1 16 P05767 1 13 P61727ASS18 P05343 1 1 HAVANA AIRJET PLUS S100205 (60035) — 71" x 26" / 1.80 m x 66 cm 2-4 2-3ºF/h 1-1.
INSTALLATION < 50°F(10°C) SET-UP INSTRUCTION IN WINTER > 59°F(15°C) > 59°F(15°C) It is important to follow these suggestions if you are setting up the spa during the winter period. This will prevent damage to the PVC material and extend the life of your product drastically. • If the ambient temperature is below 50°F(10°C), we suggest keeping the package indoor where the temperature is above 59°F(15°C) for at least 2h before inflation. This will make the spa liner more flexible and easier to set up.
1 2 3 P6609ASS16 4 5 min VANCOUVER 0.48-0.
9 10 11 MAX. MIN. max min GFCI Test IMPORTANT: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE TURNING ON THE PUMP EACH TIME. 1. Plug the GFCI into a power outlet, the indicator turns red. 2. Press the test button, the indicator turns off. 3. Press the reset button, the indicator turns red and the spa is ready for use. WARNING: The GFCI plug must be tested before each use to avoid risk of electric shock.
Air Valve Check (for spa with quick inflation/deflation valve) Always check the air valve carefully before inflation to ensure there is not an air leak. If the air valve is loose, use the provided wrench to fasten the air valve following these steps: With one hand, hold the backside of the air valve from the inner side of the spa wall and turn the wrench clockwise. NOTE: 1. Do not over tighten. 2. Do not adjust the air valve connector when the spa is in use.
USING THE SPA Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F(37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting.
NOTE: If the heating system is activated the filtration system will automatically start. NOTE: After turning off the heating system the filtration system will continue to operate. NOTE: If the spa heater is on when the water temperature is below 42.8°F(6ºC), the heating system will warm the water until 50°F(10ºC) automatically. D. MASSAGE SYSTEM BUTTON: Use this button to activate the massage system, which has a 30-minute auto-shutoff feature.
NOTE: To display the current water temperature, run the filter system for at least a minute. The water temperature as tested by an external thermometer may vary from the temperature as displayed on the spa panel by as much as approximately 35.6°F(2°C). WINTER USE INSTRUCTIONS • You can keep the spa on during winter when the temperature is lower than 42.8°F(6°C). The Freeze Shield™ system automatically keeps the water temperature between 42.
Bestway Smart HubTM Connection Guide Download Bestway Smart HubTM App from the Apple Store/Google Play Store. NOTE: The device can only be connected to one mobile phone at a time. If you need to connect to another mobile phone, press the Wi-Fi button for 3 seconds. When the indicator light flashes slowly, the device will clear the connection information from the previous mobile phone. Please follow the instructions to connect the new phone to the pump.
MAINTENANCE CAUTION: You must ensure the pump is unplugged before beginning spa maintenance to avoid risk of injury or death. Adding Air: Your spa will require additional air to be added from time to time. Changes in temperature from day to night will change the pressure in the spa and may cause a certain amount of deflation. Please follow the assembly instructions and inflate to the accurate pressure needed.
Water quality will be directly related to frequency of use, number of users and overall maintenance of the spa. The water should be changed every 3 days if there is no chemical treatment being performed with the water. It is highly recommended to use tap water for spa filling to minimize the influence of unwanted content, such as minerals. Barefoot areas and relaxing areas shall be cleaned as well. No cleaning water may flow into the spa or spa water cycle.
DISASSEMBLY AND STORAGE DRAINING THE SPA 1. 3. 2. NOTE: Dry the spa pool. 4. 5. Only for Drop stitch Spa 1. 2. 3. 4. 5. P00217 6. 8. NOTE: Lift up the spa when there is only a little water left. Damages to the handles are not covered under the warranty.
Make sure the spa and pump are completely dry. This is essential to extend the life of the spa. We recommend using the pump to blow dry the spa, pump and pipes. Remove the filter sets and discard the used filter cartridges. Re-attach the two stopper caps onto the spa’s inlet and outlet valves. It is recommended you store the spa in its original package in a warm dry place. CLEANING THE SPA Detergent residues and dissolved solids from bathing suits and chemicals may build up on the spa walls.
TROUBLESHOOTING Bestway strives to provide the most trouble-free spas on the market. If you experience any problems whatsoever, do not hesitate to contact Bestway or your authorized dealer. Here are some helpful tips to help you to diagnose and rectify some common sources of trouble. Problems Probable Causes Solutions Pump does not operate - Power failure - GFCI broken - Check power source - For assistance, please visit the support section on our website, www.bestwaycorp.com.
Problems Probable Causes Solutions The pump has been connected to the wrong band If the router your pump is connected to is dual-band and currently not connecting to a 2.4GHz network, please switch to another band of the same router (2.4GHz) and try to pair pump heater again. 5GHz networks are not supported. The spa pump location is too far from the router. Check with your cell phone to see if there is full Wi-Fi signal.
ERROR CODES CAUSES REASONS SOLUTIONS The water flow sensors work without pressing the filter or heat button. 1. The water flow sensor flags didn’t fall back into the correct position. 2. The water flow sensors are broken. 1. Unplug the plug, strike the side of the pump but not violently, and plug it back in. 2. For assistance, please visit the support section on our website, www.bestwaycorp.com.