20121211 issue 3 For warranty service call 1300 373 199(Australia) or 0508 123108(New Zealand) to connect you to the nearest authorised service centre CGH6401 CGH6401-F CGH9501 CGH9501-F BG604X BG604X-F BG905X BG905X-F
Bellini – 60/90cm gas hob Installation and Operating Instructions Contents Page 1. INTRODUCTION AND SAFETY WARNINGS 1 2. OPERATING INSTRUCTIONS 2 3. CLEANING INSTRUCTIONS 3 4. TROUBLESHOOTING 4 5. INSTALLATION 5 6. WARRANTY SERVICING and PARTS 10 7.
Bellini – 60/90cm gas hob 1. INTRODUCTION AND SAFETY WARNINGS Congratulations on your investment in Bellini, quality stainless steel gas hotplates. Please carefully read the following installation and operating instructions to ensure you get the safest operation from this appliance. These instructions apply only to the models CGH9501 and BG905X – 5 burner models and the CGH6401 and BG604X – 4 burner models, for use with Natural Gas or Universal LPG.
Bellini – 60/90cm gas hob 2. OPERATING INSTRUCTIONS LIGHTING THE BURNER The hotplates are fitted with mains powered electronic spark ignitors, so must be connected to mains power supply (i.e. nominal 230 V ac) to operate. If power is not available, the hotplate will still work but the burners will have to be lit with a match or similar. Depressing the gas control knob of any burner will activate the spark ignition for all burners.
Bellini – 60/90cm gas hob 3. CLEANING INSTRUCTIONS GENERAL Cleaning and maintenance should be carried out with the appliance cold especially when cleaning the enameled parts. Avoid leaving alkaline or acid substances(lemon juice, vinegar etc.) on the surfaces. STAINLESS STEEL The stainless steel hob of the hotplate must be cleaned regularly (e.g. weekly) to ensure long life expectancy of the hotplate. Ensure hotplate has cooled. Wash down with warm soapy water and rinse with clean water.
Bellini – 60/90cm gas hob 4. TROUBLESHOOTING Servicing of the hotplates must only be done by an authorised service representative (see back of this booklet) and the hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted. Abnormal conditions include : Excessively yellow or sooting flame type. : Flame lifting off the burner ports. : Flame lighting back into the burner (normally associated with a popping sound).
Bellini – 60/90cm gas hob 5. INSTALLATION IMPORTANT NOTE: Refer to the Warnings in Section 1 of these Instructions. This hotplate must be installed in accordance with: • AS 5601 - Gas Installations (for Australia) • NZS 5261 – Code of Practice for the Installation of Gas Burning Appliances and Equipment (for New Zealand) • Local gas fitting regulations • AS/NZS 3000 – Electrical Installations (Wiring Rules) • Building codes • Any other relevant statutory regulations.
Bellini – 60/90cm gas hob Model CGH9501: Model BG604X: Rev: 8-9-2010 Bench cutout size, 830 mm wide x 473 mm deep. Bench top thickness, 30 – 40 mm (3 – 4 cm). Bench cutout size, 555 mm wide x 473 mm deep. Bench top thickness, 30 – 40 mm (3 – 4 cm).
Bellini – 60/90cm gas hob Model BG905X: Bench cutout size, 830 mm wide x 472 mm deep. Bench top thickness, 30 – 40 mm (3 – 4 cm). Once satisfied that minimum clearances to combustible can be achieved, cut out the bench top to the dimensions specified. Apply the adhesive sealing tape to the underside lip of the burner box. Shown at G opposite. Place burner box into cutout hole and fit clamping brackets to clamp the hotplate to the bench.
Bellini – 60/90cm gas hob Then a particle board or similar heat baffle must be installed under the hob to prevent accidental touching of the underside surface. Leave sufficient rear clearance to access gas and electrical connections. ELECTRICAL CONNECTION: Install a 10 amp general purpose outlet (GPO) in accordance with relevant electrical standards and/or codes of practice applicable.
Bellini – 60/90cm gas hob For the Models CGH9501, BG604X and BG905X, light the Triple Ring and Auxiliary burner and adjust test point pressure to 1.00 kPa. Turn the two burners off and on again and recheck the pressure is same as set previously or adjust as required. TEST FOR CORRECT OPERATION: After installation and test point setting, each burner ignition and operation must be tested individually and with all burners operating. This testing must be done by the installer before leaving.
WARRANTY 1.1 In this warranty: 1.1.1 Australian Consumer Law means the law as set out in Schedule 2 of the Competition and Consumer Act 2010; 1.1.2 Company means GSM Sales Pty Ltd ABN 53 007 682 475 of 142-144 Fullarton Road, Rose Park SA 5067. Telephone 08 8122 2390. Email admin@gsmsales.com.au; 1.1.3 Consumer means a “consumer” as that term is defined in Section 3 of the Australian Consumer Law as the original purchaser of a Bellini product; 1.1.
1.8 You must provide proof of your purchase of the Bellini product and the date of purchase in order to obtain the benefit of this warranty. 1.9 If you live outside the service area of the Company or one of its service agents, this warranty does not cover the cost of transport of the Bellini product for service nor the service agent’s traveling costs to and from your home. 1.