Hydronic Heating and Plumbing Products A-50P
Service and support from the most trusted name in the industry – Bell & Gossett®. The Bell & Gossett name has always stood for uncompromising quality and dependability. That’s evident in the way our products are built and backed by our outstanding customer service and support team. Your local Bell & Gossett representative is available any time and is an experienced professional with a wealth of technical expertise.
The Most Complete Line of Hydronic Heating and Plumbing Products. All from a Single Source – Bell & Gossett. Table of Contents Page Number Pumps ecocirc Series Heating/Cooling Circulators ........................................ 4-5 ecocirc XL Series Heating/Cooling Circulators .................................... 6-8 ecocirc Series Potable Water Pumps ................................................... 9 ecocirc wireless Potable Water Kit .......................................................
CIRCULATORS ecocirc® auto Heating/Cooling Circulator Description HFRFLUF DXWR DUH GHVLJQHG ZLWK KLJKO\ HIŵFLHQW HOHFWURQLFDOO\ FRPPXWDWHG SHUPDQHQW PDJQHW PRWRU (&0 30 7HFKQRORJ\ VSHFLŵFDOO\ IRU K\GURQLF V\VWHPV Ideal for hydronic systems with zone or thermostatic valves, the ecocirc 19-14 auto can be used as replacements for existing circulators with induction motors as well as new construction as primary or zone circulators.
CIRCULATORS ecocirc® vario Heating/Cooling Circulator Description HFRFLUF YDULR FLUFXODWRUV DUH GHVLJQHG ZLWK KLJKO\ HIŵFLHQW HOHFWURQLFDOO\ commutated permanent magnet motor (ECM/PM technology), specially for hydronic systems. The ecocirc 19-14 vario has a constant curve control, which allows the pump to follow the natural hydraulic curve of a circulator. Basically acts the same as a VWDQGDUG VSHHG SXPS H[FHSW ZLWK D VWHS OHVV GLDO UHVXOWLQJ LQ LQŵQLWH speed control.
CIRCULATORS ecocirc® XL +LJK HIŵFLHQF\ ODUJH ZHW URWRU SXPS IRU KHDWLQJ cooling and potable water systems Description 7KH HFRFLUF ;/ LV D KLJK HIŵFLHQF\ YDULDEOH VSHHG ZHW URWRU SXPS ZLWK integrated drive. The circulator is available in cast iron or lead-free bronze and has a broad operating temperature range of 14°F to 230°F (-10°C to 110°C). The ecocirc XL is suitable for both hot and chilled water systems. 7KH HFRFLUF ;/ FLUFXODWRU LV GHVLJQHG ZLWK D KLJKO\ HIŵFLHQW HOHFWURQLFDOO\ commutated perman
CIRCULATORS ecocirc® XL +LJK HIŵFLHQF\ ODUJH ZHW URWRU SXPS IRU KHDWLQJ FRROLQJ DQG SRWDEOH ZDWHU V\VWHPV User-friendly interface With only four logically placed buttons on an intuitive interface, it’s easy to set and operate the new ecocirc XL. Advanced settings enable custom programming, accessible via a PC, smartphone or wireless enabled device. 6HOI ŶXVKLQJ PHPEUDQH Allows clean water to cool and lubricate the motor bearing. Restricts entry of abrasive particles. Economical operation $ KLJKO\ HIŵFLHQW
CIRCULATORS ecocirc® XL +LJK HIŵFLHQF\ ODUJH ZHW URWRU SXPS IRU KHDWLQJ FRROLQJ DQG SRWDEOH ZDWHU V\VWHPV STANDARD OPERATING MODES Constant Speed Night Time Setback 7KH SXPS PDLQWDLQV D FRQVWDQW VSHHG DW DQ\ ŶRZ UDWH 7KH GHVLUHG speed is set on the interface panel of the pump. The pump will automatically reduce speed when there is DQ DEUXSW FKDQJH LQ ŶXLG WHPSHUDWXUH 7KH FKDQJH LQ ŶXLG temperature is from a boiler operating in night time setback mode. The built-in temperature sensor is used.
CIRCULATORS ecocirc® Series Potable Hot Water Recirculation Pumps - Whole House Description e3 FLUFXODWRUV DUH HQHUJ\ HIŵFLHQW FLUFXODWRUV XVLQJ SHUPDQHQW PDJQHW (&0 HOHFWURQLFDOO\ commutated motor) technology. The e3 FLUFXODWRUV DUH GHVLJQHG VSHFLŵFDOO\ IRU SRWDEOH water applications. These circulators are lead-free* and come with a variety of options including a temperature sensor, various body styles, assembled with electrical cord and plug.
CIRCULATORS ecocirc® wireless Potable Hot Water Recirculation Kit Description The ecocirc wireless is a potable hot water recirculation kit (a pump and valve combination) for instant supply of hot water supply throughout the entire house. The ecocirc pump is installed on the supply side of the hot water source and the mixing valve under the sink farthest away from the hot water source. The pump and valve are in constant wireless communication.
CIRCULATORS autocirc® Series Potable Hot Water Recirculation Pumps - Undersink Description autocirc® FLUFXODWRUV DUH HQHUJ\ HIŵFLHQW XVLQJ SHUPDQHQW PDJQHW (&0 (electronically commutated motor) technology. The autocirc circulators DUH GHVLJQHG VSHFLŵFDOO\ IRU VWDQGDUG ZDWHU KHDWHUV 7KHVH FLUFXODWRUV DUH lead-free* and are assembled with a timer, cord and plug. Materials of Construction e3-4_-/BDPRC Pump Body: Lead-Free* Brass 2 5LQJ (3'0 Bearing: Carbon/Ceramic ,PSHOOHU 1\ORQ 332 0RWRU +LJK (IŵFLHQ
CIRCULATORS LS Condensate Removal Pump For Condensing Boilers and Air Conditioning /Cooling Systems Description 7KH /6 FRQGHQVDWH UHPRYDO SXPSV DUH HQHUJ\ HIŵFLHQW OLIWLQJ VWDWLRQV WKDW use permanent magnet, ECM (electronically commutated motor) technology. 7KH /6 FRQGHQVDWH UHPRYDO SXPSV DUH GHVLJQHG VSHFLŵFDOO\ IRU XVH LQ DSSOLFDWLRQV ZKHUH WKH UHPRYDO RI FRQGHQVDWH ŶXLG LV QRW SRVVLEOH E\ JUDYLW\ Materials of Construction Pump Housing: ABS Material 2 5LQJ (3'0 RU 9LWRQ Bearing: Carbon/Alumina Ceramic
CIRCULATORS ecocirc® SC Solar Pump Spherical Motor Pump Application Ř 7KH HFRFLUF VRODU SXPS FDQ EH XVHG IRU PRVW FLUFXODWLRQ SXPS applications without connection to the power grid with direct connection to a photovoltaic panel. Ř 7KLV SXPS LV SHUIHFW IRU VLQJOH IDPLO\ KRPH WKHUPDO solar systems or any circulation pump application where conventional power is not available, on closed loop systems 2.
CIRCULATORS Bell & Gossett Cast Iron Wet Rotor Circulators / NRF Description Materials of Construction A residential or light commercial, maintenance free, axial flanged, in-line, cast iron, wet rotor circulation pump for hydronic heating systems. UL and cUL Listed.
CIRCULATORS Bell & Gossett Cast Iron Wet Rotor Circulators / NRF Reliable, maintenance-free, whisper quiet wet rotor circulators designed for residential and light commercial heating systems.
CIRCULATORS Lead-Free Wet Rotor Circulators for Potable Water / NBF & SSF Description A residential or light commercial, maintenance-free, in-line, lead-free* bronze or stainless steel, wet rotor circulator for potable water systems and other applications. Flanged, union or sweat models available. UL and cUL listed.
CIRCULATORS Lead-Free Wet Rotor Circulators for Potable Water / NBF & SSF – continued Single Speed–NBF/SSF 60 HZ Performance Curve Three Speed–NBF 60 HZ Performance Curve CIRCULATORS Series LR™ Maintenance-Free Circulators Materials of Construction Pump Body: LR-20WR: Cast Iron LR-15BWR: Lead-Free* Bronze Impeller: Noryl® Shaft: Ceramic Bearings: Carbon &6$ FHUWLŵHG WR 16) $16, WKDW SURGXFW FRQWDLQV OHVV WKDQ 0.25% lead content by weight on wetted surface.
CIRCULATORS Maintenance-Free Circulators a superior alternative to large wet rotor pumps Operating Data Maximum Working Pressure 150 PSI (10.
CIRCULATORS Oil Lubricated Circulators Three-Piece PD 40 PD 38 Operating Data PD 37 Maximum Working Pressure: 125 PSI (8.6 bar) 0D[LPXP 2SHUDWLQJ 7HPSHUDWXUH Standard Seal: 225°F (107°C) continuous Special Seals: 250°F (121°C) continuous PR PD 35 HD 3 2-1 /2” SE R1 D3 2” 00 &L HV Specifications Model No. Series 100 Series PR Series HV 2" 2-1/2" LD3 HD3 PD-35S PD-35T PD-37S PD-37T PD-38S PD-38T PD-40S PD-40T Cast Iron Model No. Part No.
CIRCULATORS Series 60 In-Line Mounted Centrifugal Pump Description A maintenance-free, in-line, cast iron centrifugal pump for header pump applications. Designed for a variety of applications Materials of Construction Ř +\GURQLF KHDWLQJ FRROLQJ V\VWHPV Ř 'RPHVWLF ZDWHU Ř )OXLG WUDQVIHU Product Features Ř 0DLQWHQDQFH IUHH SXPS DQG PRWRU GHVLJQ Ř ,QWHUQDOO\ VHOI ŶXVKLQJ PHFKDQLFDO VHDO Ř ;/,,p OXEULFDWLRQ V\VWHP Ř )DFWRU\ WHVWHG 4XDOWL\ 3URGXFW Ř ,62 FHUWLŵHG Ř 1HRSUHQH FRXSOLQJ Ř &RPSDFW GHVLJQ Ř
CIRCULATORS Series 60 In-Line Mounted Centrifugal Pump 6SHFLŵFDWLRQV MODEL SUCTION AND DISCHARGE SIZE INCHES NPT 601,602 & 603 1 PUMP DIMENSION IN INCHES (MM) F G K L M N P R S T 6-7/16 (164) 3-7/16 (87) 3-5/8 (92) 1-3/8 (35) 2-1/2 (64) 7-1/2 (190) 3/4 (19) 5 (127) 6 (152) 11 (279) 604,605 & 606 1-1/4 6-7/16 (164) 3-7/16 (87) 3-5/8 (92) 1-3/8 (35) 2-1/2 (64) 7-1/2 (190) 3/4 (19) 5 (127) 6 (152) 11 (279) 607,608 & 609 1-1/2 6-9/16 (167) 3-5/8 (92) 3-3/4 (95) 1-3/8 (
FLANGES Check-Trol™ Isolation Flow Control Flange Description The Check-Trol flange is a combination isolation valve, flow control valve, and companion flange for circulators. The ball valve allows the circulator to be removed from the system without draining the system. The internal spring check prevents gravity circulation. Free floating companion flange makes pump installation a snap.
ISOLATION FLANGES Description The isolation flange is a combination of an isolation ball valve and a companion flange for circulators. The isolation flange allows easy service or replacement of the circulator without the need to drain the system. The isolation flange fits the Bell & Gossett NRF/NBF/SSF wet rotors, Series PL, Series 100, HV, PR and LR circulators.
3 CONTROLS ecocirc e SERIES TIMER ® Description To increase the overall efficiency of a domestic hot water recirculating system and to reduce water wasted while waiting for hot water, the e3 Timer can be installed on all e3 pumps. The timer is easily installed by removing the motor end cap, plugging in the timer and setting the timer schedule ZLWKRXW DQ\ ZLULQJ 7KH WLPHU FDQ EH XVHG LQ GLIIHUHQW VHOHFWLRQV 21 2)) DQG 7,0(5 7KH 21 VHOHFWLRQ RSHUDWHV WKH SXPS FRQWLQXRXVO\ WKH 2)) VHOHFWLRQ WXUQV WKH
RELAYS ZONETROL II AZ-1A™ Snap-On Pump Relay Description 7KH =21(752/ ,, $= $ VQDS RQ UHOD\ ER[ LV DQ HDV\ WR LQVWDOO VLQJOH ]RQH pump controller that mounts directly on any Bell & Gossett wet rotor circulator 15) 1%) RU 6HULHV 3/ ERRVWHU 7KH $= $ WXUQV WKH SXPS DQG ERLOHU 21 DV thermostat calls for heat. Using the wire nuts provided with the package, the AZ-1A is quickly assembled onto any NRF/NBF or 1/12 to 1/6 HP Series PL.
RELAYS ZONETROL™ Switching Relays for Zoning with Valves Features Ř IDFWRU\ WHVWHG JXDUDQWHHV RSHUDWLRQ Ř )LYH \HDU OLPLWHG ZDUUDQW\ WKH EHVW LQ WKH EXVLQHVV Ř 5HSODFHDEOH VWDQGDUG œLFH FXEHŔ W\SH UHOD\V DOORZ XS WR DPSV 1/3 HP per individual zone Ř 6HOHFWDEOH SULRULW\ IRU GRPHVWLF KRW ZDWHU Ř PLQXWH EXLOW LQ SULRULW\ WLPHU KHOSV SUHYHQW KRXVH IUHH]H XS QR DGGLWLRQDO plug-in cards required Ř $XWRPDWLFDOO\ UHVHWDEOH IXVH SURWHFWV FRQWUROOHU IURP RYHUORDG HOLPLQDWHV “no he
VALVES Snap Zone™ Valve Description Snap Zone valves are precision engineered four wire thermoelectrically operated valves designed for heating and cooling systems. The valve opens and closes based upon the voltages applied to the actuator. Use the Bell & Gossett Snap Zone Valves to speed installation time and reduce callback times to customers. The actuator can be installed or removed at any angle on the adapter ring. The compact design and universality in the DFWXDWRU PRXQWLQJ SRVLWLRQ DOORZV IRU HDV\ LQV
BALANCE VALVES Lead-Free* Circuit Setter® Plus Description The Circuit Setter Plus and Circuit Setter Plus RF provide the perfect balance of adjustability and HIŵFLHQF\ IRU SRWDEOH ZDWHU DQG +9$& V\VWHPV They are precisely calibrated for use as a SUHVHWWDEOH EDODQFH YDOYH YDULDEOH RULŵFH ŶRZ meter and positive shut-off service valve. They DUH DOVR GHVLJQHG IRU RSWLPDO V\VWHP HIŵFLHQF\ and water conservation.
TM TM BALANCE VALVES Circuit Sentry Flo-Setter Description New GPM dial The Circuit Sentry Flo-Setter valve is a field adjustable pressure independent flow limiter that maintains set flow rates regardless of pressure fluctuations in the V\VWHP HOLPLQDWHV RYHUIORZ Circuit Sentry Flo-Setter A ' E Ř 7KH XQLTXH GPM dial is easy to set. Requires no instruments, charts or wheels Ř 6DYHV SXPS HQHUJ\ DQG LPSURYHV FRLO HIILFLHQF\ Ř 1R PLQLPXP VWUDLJKW SLSH OHQJWKV UHTXLUHG Ř ,QWHJUDWHG SUHVVXUH / tem
VALVES Flo-Control™ Valves Description Flo-Control valves prevent gravity flow in forced hot water systems, and permit summer/winter operation of indirect water heaters. Features Ř &RPELQDWLRQ VWUDLJKW DQJOH FRQILJXUDWLRQV LQ VL]HV 3/4” to 2” for ease of installation. Ř 5HPRYDEOH FDS DOORZV HDV\ FOHDQLQJ DQG VHUYLFH without removing pipe connections. Ř 0DQXDO RSHUDWLQJ SRVLWLRQ IRU YHUWLFDO OLIW GLVF WR permit gravity circulation.
VALVES Hydrotrol™ Flow Control Valves Description The Hydrotrol (HT) flow control valve is used to prevent overheating of zones due to gravity flow in hydronic heating systems and will permit summer-winter operation of indirect water heater. The HT valve allows fluid to pass when the system or zone pumps start. When the system or zone pumps are not operating, the HT valve remains closed, preventing gravity circulation.
VALVES Pressure Reducing Valves Description FB-38TU FB-38 Reducing valves fill the system to a preset pressure for optimum performance. F-3TU B-38TU B-38 Features Ř )DVW ILOO IHDWXUH UHGXFHV start-up time and labor. Ř /RZ LQOHW SUHVVXUH FKHFN YDOYH helps prevent loss of system pressure if the supply water drops below system pressure. Ř &RQYHQLHQW FOHDQDEOH VWUDLQHU is designed to prevent dirt and sediment from entering the system.
ACCESSORIES Copper Red Ring Monoflo® Fittings Description Copper Red Ring Monoflo Fittings let you use a single pipe to serve as both supply and return main. Features Ř &RQQHFW ULVHUV WR WKH PDLQ DVVXULQJ SURSHU GLYHUVLRQ RI ZDWHU to each heating unit regardless of type and its position in the system. Ř 5HFRPPHQGHG IRU PRVW LQVWDOODWLRQV LQFOXGLQJ FDVW LURQ non-ferrous base boards, free-standing radiation or convectors. Ř 2QO\ RQH ILWWLQJ LV QHHGHG IRU PRVW LQVWDOODWLRQV IRU DGHTXDWH diversion for up
AIR SEPARATORS EASB-Jr Enhanced Air Separator Description Dimensions & Weights Operating Data Bell & Gossett’s Model EASBMaximum Working Pressure 150 PSI (10 bar) JR Enhanced Air Separator 0D[LPXP 2SHUDWLQJ 7HPSHUDWXUH 250°F (121°C) automatically removes entrained air bubbles in hydronic systems. As Materials of Construction fluid enters the EASB-JR, the velocity is decreased creating a low pressure Body & Cap Brass area.
HYDRONIC SPECIALTIES RV-125A Readout Valve and RP-250B Readout Probe TB– Thermoflo® Balancer The RV-125A is designed for use wherever pressure tappings are required to monitor flow or pressures. The Readout Valve is fitted with an EPT insert which incorporates a unique check valve feature designed RP-250 RV-125 to check flow when the Readout Valve is not being used to monitor flow. Use companion RP-250B Readout Probes with the RV-125A Readout Valve.
ACCESSORIES PSH - Primary/Secondary Header Description Operating Data The B&G low-loss header, Model PSH, is a combination air separator and manifold that creates independent primary and secondary circuits. The B&G Model PSH is equipped with a purge valve allowing the user to remove any debris deposited on the bottom of the vessel and an air vent releasing trapped air in the system.
TANKS +)7 'LDSKUDJP 7DQNV Ř ([SDQVLRQ 7DQNV for Hydronic Heating Description Specifications Bell & Gossett HFT expansion tanks are designed to absorb the force of thermal expansion in hydronic heating systems. Series HFT tanks for hydronic heating systems are available in sizes from 2—86 gallons. The Series HFT tank is designed to absorb the force of thermal expansion of heating water to maintain proper pressurization in a closed hydronic system.
TANKS PT Diaphragm Tanks Expansion Tanks for Potable Water Systems Description Bell & Gossett PT expansion tanks are designed to absorb the force of thermal expansion in domestic potable water systems. Tanks for potable water systems, Series PT and PTA (ASME construction) are available in sizes from 2—528 gallons.
VALVES TPV – Tank Purge Valves +RUL]RQWDO 7DQN Installation with Rolairtrol Air Separator Description Combination full port shut-off valve and drain valve used to connect an expansion tank to the system. It is important that the pre-charge in an expansion tank be maintained at the proper pressure at all times. This pressure is the lowest system operating pressure. When the tank’s pressure is adjusted, there should be no system liquid in it.
HEAT EXCHANGERS Brazed Plate Heat Exchangers Description Model BPX brazed plate heat exchangers offer the highest level of thermal efficiency and durability in a compact, low cost unit. The corrugated plate design provides very high heat transfer coefficients, resulting in a more compact design. The unit’s stainless steel plates are vacuum brazed together to form a durable, integral piece that can withstand high pressure and temperature.
HEAT EXCHANGERS Brazed Plate Heat Exchangers Quick Selection Tables Domestic Water Heating Domestic Water Heating - Double Wall Boiler Side: Water 180º F supply, 130º F return Domestic Water Side: Water 50º F supply, 140º F return Boiler Side: Water 180º F supply, 130º F return Domestic Water Side: Water 50º F supply, 140º F return Boiler Side Domestic Water Side B&G Heat Pipe Exchanged Flow Pressure Drop Flow Pressure Drop Pump †† BTU/Hr GPM Selection† Size PSI GPM PSI Model BP400-10 (¾" MPT) BP400-2
WASTEWATER Submersible Sump Pumps Description 6XPS SXPSV DUH VSHFLŵFDOO\ GHVLJQHG IRU EDVHPHQW GUDLQLQJ GHZDWHULQJ and water transfer. It has a range of capacities up to 70 GPM and maximum heads of 37 TDH ranging from 1/4 HP to 3/4 HP. The stainless steel or cast iron construction is available with 1-1/2” discharge connections. Battery back-up sump pumps also available for emergency back up service in the event of a power outage. SC 6.4” 6SHFLŵFDWLRQV Ř 0D[LPXP VROLGV Ŕ 9.
WASTEWATER Submersible Sump Pumps BSP0311 105/9” Cast Iron Sump Pump 75/9” 101/8” 31/4” Specifications Model Number Part Number HP Volts Amps BSP BSP0311 1/3 115 10 BSP BSP0311M 1/3 115 10 Min. Circuit Phase Breaker 15A 1 15A 1 Float Min. Min. Min. Cord Discharge Max.
Genuine Bell & Gossett Parts When replacing parts in your customers’ B&G booster or other hydronic specialties, don’t settle for anything other than genuine B&G parts. You owe it to your customers and to yourself to do it right the first time. Bell & Gossett parts are designed and engineered strictly for the Bell & Gossett boosters. Substitute parts may seem to cost less. But more often than not, they actually cost a lot more, when they do not hold up on the job.