Universal Distribution Antenna System RAM2241 User Manual Issue V0.
RAM2241 RU User Manual Copy Right @Telestone Technologies Co., Ltd, 2012. All right reversed. Printed in the P.R.C. About This Manual This publication provides a description of the WFDSTM Universal Distribution Antenna System(U-DAS) plus instructions for installing the main components. An overview of U-DAS and a complete description of the Main Unit (MU) are provided in the U-DAS system RS2200 User Manual.
RAM2241 RU User Manual 5 Trouble shooting 6 Specification 7 appendix Conventions Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury. Indicates a hazard with a medium of low level of risk, which if not avoided, could result in minor or moderate injury.
RAM2241 RU User Manual Version 0.2(2012-06-18) General safety precautions All safety attention to realize As the guarantee person and equipment safety, once operating the installation, operation and maintenance of the equipment, please follow the equipment identification and manual that all of the safety precautions. In the manual, "note", "warning" and "dangerous" matters, doesn't mean that all security matters should abide by, just as all safety precautions supplement.
RAM2241 RU User Manual Personal safety Banned in the thunderstorm weather to operate the equipment and cables. Open hole look straight into the optical fiber, in order to prevent the laser burn eyes. If fire, should be evacuated from the building or equipment area, and press the fire alarm, or dial the fire alarm call. In any case, it is strictly prohibited to once again into the burning building.
RAM2241 RU User Manual alternating current operation, and equipment installation , or you will have life risks. Big leakage current Before turn on the power, the equipment must grounding, otherwise you will endanger personal and equipment safety. Power supply cord Banned connected, disconnected the power cord when charging the equipment. The power cord in the moment of contact with conductor core will produce electric arc or edm, may lead to fire or eye injuries.
RAM2241 RU User Manual Before the light source has been shut down, banned to look directly into the end of any optical fiber. An optical power meter should be used to verify active fibers. A protective cap hood must be immediately placed over any fiber connector to avoid the potential of dangerous amounts of radiation exposure. Fiber operation Please follow the optical fiber operation requirements: Only properly trained personnel to do cutting and welding optical fiber operation.
RAM2241 RU User Manual When equipment installation, please clearly marked the number and name of fiber link to avoid the fiber connection error. Fiber link error will lead to U-DAS2200 system does not work normally. In U-DAS2200 system, up link and down link are independent optical transmissions. Wrong connection for UL and DL, or wrong connections for different ports from higher level can cause equipments do not work normally.
RAM2241 RU User Manual Inside MU and EU, lower power supply of AC/DC is assembled, MU and EU cannot offer of lower equipments remote power supply by themselves. But MU and EU both have the spreader plate which divides into 8 roads input DC power supply for RUs. Reboot equipment The ship type switch of MU front panel is for AC power input and backup battery hige switch. No DC power switches for MU. DC power hige control is controlled by PSU. If need to reboot MU, there are three options.
RAM2241 RU User Manual Content 1 Overview .......................................................................................................................1-1 1.1 U-DAS2200 system ....................................................................................................................... 1-1 1.1.1 System structure introduction ............................................................................................... 1-2 1.1.2 Remote distance............................................
RAM2241 RU User Manual 6.1.4 Environment ......................................................................................................................... 6-3 6.1.5 Power Consumption ............................................................................................................. 6-3 7 Appendix.......................................................................................................................7-1 7.1 Tools ..............................................................
RAM2241 RU User Manual 1 Overview 1.1 U-DAS2200 system U-DAS2200 system is a solution for transmission and distribution of wireless signals solutions, is a kind of intelligent and active integrated antenna distribution system. Working band can cover from 680 MHz to 2200 MHz for all of the cellular mobile communication frequency. Meet from simple to complex all kinds of indoor wireless access network requirements.
RAM2241 RU User Manual As shown in Figure 1-1 shows, U-DAS2200 system the basic equipments: the main unit (MU), expansion unit (EU), remote unit (RU) composition. When the system working in many business state, it needs to increase the wireless access unit (WAU). The wireless access unit (WAU) combines more signals from the base station, and apply the RF signal to master unit (MU). Master unit (MU) will convert the RF signals to light signals, and expanded to 8ways to lower equipment.
RAM2241 RU User Manual 2 RAM2241 Remote Unit 2.1 RAM2241 Remote Unite Exterior Figure 2-1 RAM2241 Remote Unite Exterior 2.2 RAM2241 Remote Unite Function RAM22XX series Remote Unite (RU) to realize the optical signals are converted to RF signal, and then amplify the multiple frequency RF signal and output by the antenna. At the same time, you can accept superior equipment management, to report devices work status information to the superior equipment.
RAM2241 RU User Manual RAM22XX series Remote Unite (RU) the main Function includs: with 1 to superiors equipment connection, to realize the optical signals are converted to RF signal; superior equipment can BE MU or EU; can accept the equipment's management, in MU place, can through the PC remote the machine working status, query, configuration , set machine work parameters, etc.; support from higher level equipment place take electricity; 2.
RAM2241 RU User Manual 2.4 RAM2241 Remote Unite Panels Figure 2-3 RAM2241 Remote Unite Panels 2.
RAM2241 RU User Manual Number Interface Quantity 5 RF antenna port 1 Connector Type Application N Type Female RF output Note:the lights working status introduction is in Chapter 5 2-4
RAM2241 RU User Manuel 3 Remote Unit Installation 3.
RAM2241 RU User Manuel 1) Installation M8 Expansion bolt Figure 3-2 Expansion bolt Installation RU is install LED indicator on the wall Figure 3-3 RAM2241 RU Installation 2) The terminal box is install LED indicator next to the RU; 3-2
RAM2241 RU User Manuel 3.2 Equipment Connection 1)RF cable connection Figure 3-4 RAM2241 RU power supply connection 2)Fiber connection Figure 3-5 RAM2241 RU fiber connection Take down the dust cap of the equipment, and properly kept, has been used next time. On the positive direction, guarantee the connector center in the same axis, bolt and card slot in the same direction, such as shown in Figure 3-5.
RAM2241 RU User Manuel Figure 3-6 RU power line cable connection Sick the RJ45 connector to the internet socket, the key to the neck such as shown in Figure 3-6 ,nip the end of the plug and push slightly to the socket.When it clicks,they are con nected in place and the RJ45 connector wouldn't get loose.
RAM2241 RU User Manuel Note, RJ45 joint should adopt standard of T568A or T568B line sequence. If line sequence is wrong then may cause permanent damage to the device.
RAM2241 RU User Manuel 4 U-DAS2200 Opening 4.1 The preparing work before opening 4.1.1 The matching of the access power of signal Design principle: According to insertion loss of different wireless access unit and the output power of different base stations, we calculated the value of the attenuation, make after combine the all the signal together then the input power into the DL of main unit is 0 dBm.
RAM2241 RU User Manuel In the second step, according to the actual configuration business quantity, estimate power of every business need to infuse the MU. If it is 4-band system, the input power will be forced into each MU adjustment for-6 dBm as far as possible. 3-band system, each power will be forced into MU is adjustment for-5 dBm. 2-band system, each power will be forced into MU adjustment for-3 dBm. So the total power is easy to control requirements in range.
RAM2241 RU User Manuel In U-DAS,MU is in 0 level,no need to configured。The equipment under the MU is level-1 Expansion Unit,so that the first address is“1”for this EU。If a EU is under the level-1 EU, then this EU will be level-2, and the first address is configured to “2”。 Wrong coding the address of Expansion Unit will cause the higher equipment can not find it, can’t do the monitor control.
RAM2241 RU User Manuel Figure4-3 Address configuration As Figure4-3 shows EU01 is bellow MU,in level 1,so the left address is“1”,E01 is connected to the port1 of Main Unit, so the right address of EU01 is“2”。EU02 is bellow EU01,in lever-2,and EU02 is connected to the port 6 of EU01,so the address configure on EU02 is“2”,“6”。 U-DAS2200 support two levels of EU currently. 4.
RAM2241 RU User Manuel The most troubles in the opening U-DAS2200 are wrong connections in the link engineering, wrong address configuration of the equipments and big loss in fiber link engineering. Check the equipments based on the checking list before power up the equipments. Table 4-1 Main Unit Check List Table No. Check Items Check Requirement 1 MU Installation environment See 3.1 2 Grounding Line See 3.2 3 Fiber port connection See 3.2 4 CAT-5 Connection See 3.
RAM2241 RU User Manuel 4.2.1 Equipment Power up and Debug The power up flow is from lower level of equipments to higher level of equipments.(RU-EU-EU-MU) Before power up the equipments, we need to check the installation of every equipment, the fiber link labels, and the configuration of EUs by using the Design documents The restart the “reset” on MU can refresh the system topology.
RAM2241 RU User Manuel The ship type switch of MU front panel is for AC power input and backup battery hige switch. No DC power switches for MU. DC power hige control is controlled by PSU. If need to reboot MU, there are three options. 1 Shut down AC, DC, power, and then open PSU, AC power. 2.Reset button on the panel.( only reboot the monitor module) 3.By OMT software to reboot. The ship type switch of EU front panel is for AC power input. No DC power switches for EU.
RAM2241 RU User Manuel Table 4-2 No.
RAM2241 RU User Manuel No.
RAM2241 RU User Manuel No.
RAM2241 RU User Manuel 4.2.2 Equipment operation status requiry After opening all equipments, use OMT to check the system status. It is best to check all the alarms, and check if the equipment is abnormal, at least to check if the output power of RU is meet the design.
RAM2241 RU User Manuel 5 U-DAS2200 T rouble shooting 5.1 MU trouble shooting stage Figure5-1 is MU indicator panel, HOST is for the MU self operation status, REMOTE is for the status of lower level equipments. ALL the indicator LED has 5 performance: Bright, quick flash, flash, slow flash, out. The instruction of the indicator is shown in Table 5-1。 Figure5-1 Table 5-1 No.
RAM2241 RU User Manuel No.
RAM2241 RU User Manuel No.
RAM2241 RU User Manuel No. Name port LED indicator ( DC supply) green light N … 7 … yellow RJ45 light N power port LED indicator ( only AC green supply) light N … … Function Note(status) out MU the Nth port,no Normal alarm。 bright MU the Nth port, work normal and has outputt out MU the Nth port,no output … … bright When booting, bright 3 Seconds. out Normal operation, light is OFF. bright When booting, bright 3Second. out Normal operation, light is OFF.
RAM2241 RU User Manuel Check if AC got power supply. Check if the switch bottom is on. PSU can’t be booted: Check the AC power supply connection; make sure the power resource is working. Check if the Output have short circuit. Check if the start bottom on the panel is pushed Check if the DC input connection is right(Positive to DC+, Negative to DC-) RED LINE CALE IS FOR POSITIVE; BLACK LINE CABLE IS FOR NEGATIVE;. 5.2.
RAM2241 RU User Manuel 1) Check if the DC power supply for MU is connected. 2) Check if the connection of CAT-5 cable for RU is ok. Make sure the two connectors on the CAT-5 cable have the same line- sequence. 3) If AC and DC both working, when we power up the RU(MU), fist, power up the DC, and then power up AC 5.2.3 RU Output Power is low If all the output power of RUs are low, check the input power to MU; Check if set DL ATT on the RU; Check the loss of optical link; 5.2.
RAM2241 RU User Manuel 6 U-DAS2200 Specifications 6.1 RAM2241 RU Specification 6.1.1 Performance Item Band Specification Received Range(MHz) Transferred Range(MHz) LTE 700MHz : 698-716 / 776-787 LTE 700MHz :728-746/746-757 Cellular 850: 824-849 Cellular 850: 869-894 PCS1900:1850-1910 PCS1900:1930-1990 AWS2100:1710-1755 AWS2100:2110-2155 MAX Gain 40 ±2 dB Delay Time 500ns Noise 7dB (typical) Frequency Error ≤ ±0.
RAM2241 RU User Manuel 6.1.
RAM2241 RU User Manuel 6.1.4 Environment Item Operation Temperature Specification -30~50 ℃ Ambient Temperature -20℃~70℃ ~70 Humidity RH≤85% Protection IP50,Indoor 6.1.
RAM2241 RU User Manuel 7 Appendix 7.1 Tools Philips screwdriver Flathead screwdriver diagonal pliers wire stripper RJ45 Ratcheting Crimp Tool M4, M6 75×2.
RAM2241 RU User Manuel Optical power meter Laser light source Oil pen Label 7-2
RAM2241 RU User Manuel Laptop USB-B convert USB-A cable 7-3
RAM2241 RU User Manuel 7.
RAM2241 RU User Manuel 7.3 RJ45 pins of DC power supply port of MU/EU RJ45 PIN SEQUENCE 7.
RAM2241 RU User Manuel PIN Definition line color of T568B 4 48V + blue 5 48V + blue white 6 G green 7 G white brown 8 G brown Note: if we need use 2-core DC to do the remote supply, For Positive: white orange, orange, blue, blue white For Negative: white green, green, white brown, brown FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.