Wireless Weather Station Model No.YJ-5065 User Manual Get 24/7 Customer Service & Extended Warranty Use Camera or QR Scanner to Scan Or Visit: https://sparoma.afterservice.vip/ Email: sparoma@afterservice.
Contents UK............................................................................................................................................... 1 FR............................................................................................................................................... 1 GER............................................................................................................................................ 1 ITA..........................................................
Operation Instructions....................................................................................................... 3 1. Preparations before Use.............................................................................................. 2 2. First Use........................................................................................................................... 2 3. Assembly and Installation...........................................................................................
Before Use For safe and reliable operation and optimum performance, this appliance must be operated, installed and maintained in accordance with these instructions. Please read these instructions thoroughly and gain a full understanding of the requirements, features and operation of your new appliance before attempting installation and operation. Keep these instructions handy for future reference.
About the Product 1. Product Overview 1.
2. Product Specifications Description/Item sparoma Weather Station Model YJ5065 Station Dimension 130 ×130× 60 mm Outdoor Sensor Dimension 96 ×50× 24 mm Battery for Station 3×1.5V “AAA” (MAXELL) Battery for Outdoor Sensor 2×1.5V “AAA” (MAXELL) Indoor Working Temperature -9.9℃-+50℃(14℉-+122℉) Outdoor Working Temperature -40℃-+60℃ & -40℉~+140℉ Working Humidity 20-95% RH Atmospheric pressure display 600 hPa/mb-1100 hPa/mb (17.72 inHg~32.48 range inHg) LCD Viewing area 93.
Safety Precautions Please read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. 1. Only use the product as described in this manual and use it only for household purpose. 2.
voltage and current rating corresponds with the power supply details shown on the product rating label. 9. Do not leave the product alone when plugged in. Unplug it from the power outlet when not in use and before cleaning. 10. Do not use the product with a damaged cord or plug. If it is not working as it should, for example, it has been dropped, damaged, left outdoors, or dropped into water, please contact the service center and return it for repairs. 11.
Operation Instructions 1. Preparations before Use 1) Insert 2-AA batteries into your Outdoor Sensor. 2) Insert the 5 volt power cord into an outlet, then into your station. Optional: Insert 3-AA batteries for backup. 3) The LCD displays all for 3s, and emits 1 beep at the same time. After the backlight is on for 3 seconds, it switches to the standard display mode, displays the INDOOR ambient temperature, relative humidity, and atmospheric pressure.
9) 10) 11) 12) 13) Press SET to select the Minutes. The Minutes will show. Press the + or – button to adjust the minutes. Press SET to select the Year. The Year will show. Press the + or – button to adjust the year. Press SET to select the Month. The Month will show. Press the + or – button to adjust the month. Press SET to select the Date. The Date will show. Press the + or – button to adjust the date. Press SET to select Fahrenheit/Celsius. The °F will show. Press the + or – button to select Celsius.
3) In the mode of viewing the value of MAX or MIN, press and hold the [MEMERY] key for more than 2 seconds to clear the maximum and minimum values. After cleared, the MAX value or MIN value will be transferred to the current value. 4) When the temperature continues to increase to a value of more than 1℃ & 1.8℉, the symbol of the temperature trend will display " " 5) When the cumulative value of the temperature rise or fall within 1 hour of continuous temperature does not exceed 1°C & 1.
4) 5) 6) 7) 8) 9) predict the weather conditions in the next 12 hours. There are 6 types of weather displays, and the forecast is calculated once every 6 hours.
③MSF: Time System → Time Hour → Time Minutes → Date Format → Time Year → Time Month → Time Days → Exit 4) 5) 6) 7) 8) 9) ④NO-RCC: time format→time hour→time minute→date format→time year→time month→time days→week language→exit There are 2 options for the time system: 12HR & 24HR. When changing, the system display of time, alarm time, sunrise and sunset time will all be changed. Time zone selection can be selected: ①DCF: -12 ~ 0 ~ +12.
1) 2) 3) 4) 5) 6) 2.5 Alarm setting In the standard mode, press and hold the [ALARM] key for more than 2 seconds to enter the alarm time setting mode accordingly. After entering, the time bar will automatically switch to the alarm time display, and its setting items will be displayed and flashing. In the alarm time setting mode, press the [ALARM] key to confirm the result of the setting item and switch to the next setting item.
channel. The RF receiving mode is the same as the description, but it needs to receive 3 channels before turning off the RF receiving mode. After receiving the signal, the symbol 3) 4) 5) 6) 7) 8) " " is displayed.
the ID of the channel will be automatically cleared, and the displayed temperature and 11) 12) 13) 14) 15) 16) humidity values will be cleared together, and the display will be " --.-℃" or "--.-℉" and "--%RH", re-open the RF for 3 minutes long reception, and re-receive the signal. At this time, if the built-in channel does not receive the signal, it will re-receive Signal.
2) 3) 4) 5) 6) 7) 8) 9) frequency of 1 Hz. If the signal is suddenly interrupted during the effective reception process, the RCC signal wave symbol " " is not displayed. The triangular tower symbol "" changes to display and flashes until it receives a valid signal again, and then changes to the previous effective display mode. The long RCC reception is 7 minutes.
Maintenance Cleaning and Maintenance: Switch off and unplug from the power supply before cleaning. Using a soft, moist cloth, with or without a mild soap solution, carefully clean the exterior surface of the product. Do not allow water or other liquids to run into the interior of the product, as this could create a fire and/or electrical hazard. CAUTION: Allow the product to completely cool before handling or cleaning it.
Product Disposal Products and batteries marked with this symbol must not be disposed of with normal household waste, which contain materials that can be recovered or recycled reducing the demand for raw materials. Used products with batteries should be taken to a recycling station and not be disposed of with household waste . Hand it over to the applicable collection station for the recycling of electrical and electronic equipment.
a period of (1)ONE-YEAR from the date of original purchase.
but not limited to the loss of profits, income or data due to the violation of explicit or implied warranties or conditions mentioned in this user manual. Information in this user manual is for informational purposes only. It is subject to change without prior notice, due to the manufacturer ’s continuous development program. This document supersedes and replaces all information supplied prior to the publication hereof.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.