TDS
This information is provided “as is” and no representations or warranties, either expressed or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For MSDS or to consult with a Behr Certied Coatings Professional,
call 1-800-854-0133 Ext. 2 (U.S.A. only). ©2020 Behr Process Corporation Santa Ana, CA 92704 U.S.A.
TECHNICAL DATA SHEETTECHNICAL DATA SHEET
Revised 06/2020
MASONRY, STUCCO & BRICK FLAT PAINT
NO. 270 WHITE
1 of 2
PRODUCT INFORMATION
BEHR® Masonry, Stucco & Brick Flat paint is a high-quality, acrylic latex paint with excellent hiding properties.
This interior/exterior, self-priming, mildew resistant finish also provides excellent adhesion and water repellency on
properly prepared, smooth, rough and textured masonry, stucco and brick surfaces. It is alkali-resistant up to pH 12,
easy to apply, and cleans up with soap and water.
RECOMMENDED USES:
This product is ideal for use on properly prepared and primed above grade vertical surfaces such as:
• Concrete • Concrete Block/CMU • Fiber Cement • Stucco
• EIFS • Brick • Drywall
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 270 White 126 oz / 4 oz
No. 272 Deep Base 116 oz / 14 oz
Gloss: 0 – 6 @ 60°
Sheen: 0 – 6 @ 85°
Resin Type: Acrylic
Weight per Gallon: 10.7 lb
% Solids by Volume: 30% ± 2%
% Solids by Weight: 44% ± 2%
VOC: < 50 g/L
Flash Point: N/A
Viscosity: 95 – 105 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.0 mils @ 250 sq ft/gal
Wet: 4.0 mils / Dry: 1.2 mils @ 400 sq ft/gal
Coverage: 250 – 400 sq ft/gal depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: 3/8" – 3/4" nap roller cover, depending on
surface texture.
Airless Spray:
Tip: .015" – .021"
Filter: 60 mesh
Thinning: DO NOT THIN. Product is formulated for use at
package consistency only.
Dry Time: @ 77°F & 50% RH
To Touch: 2 – 3 hours
To Recoat: 4 hours
Full Cure: 2 weeks
Longer dry time may be required in cooler temperatures
and higher humidity.
SURFACE PREPARATION:
All surfaces must be clean, free of dust, chalk, oil, grease,
wax, polish, mold and mildew stains, loose and peeling
paint, rust, and all other foreign substances.
Drywall: All drywall surfaces should be suciently sanded
smooth. Remove any remaining drywall dust prior to
priming. Allow all drywall compounds to be completely dry
prior to coating.
Masonry: All masonry surfaces must be cured at least 30
days before painting. The pH must be 12 or lower prior to
coating. Smooth masonry may require an adequate prole
for adhesion. For all other smooth concrete, create a prole
using a product such as a muriatic acid etcher to achieve a
textured prole. Use a cleaner to remove loose aggregate
and debris.
Wood: Remove mill glaze with sandpaper or use a product
such as BEHR PREMIUM® All-In-One Wood Cleaner No. 63 to
open the pores of the wood and follow all label instructions.
For severe stains caused by mold, mildew, algae and fungus,
apply a mildew stain removing product. Set nails and ll
holes, scratches, and gouges with the appropriate wood
ller and let dry completely. Remove all dust with a wiping
cloth. Fill all gaps with a 100% acrylic, siliconized, paintable
caulking and allow to dry completely. Patched and lled
surfaces should be sanded smooth and dusted clean prior
to coating.
Steel: Minimum surface preparation is Hand Tool Cleaning
in accordance with SSPC-SP2. Remove all oil and grease from
the surface with a solvent in accordance with SSPC-SP1.
For optimal performance, use Commercial Blast Cleaning
in accordance with SSPC-SP6. Prime the area with a
rustinhibitive primer such as BEHR Interior/Exterior Metal
Primer No. 435 the same day as cleaned.
Galvanized Steel: Solvent clean new galvanized metal in
accordance with SSPC-SP1 to remove oil and grease from
the surface. Pre-treat with a phosphoric acid solution or
a commercially-available etching solution. Galvanized
metal that has been passivated with chromates or silicates
may require brush blasting in accordance with SSPC-SP16
to remove these treatments. Rusty galvanizing requires
a minimum of Hand Tool Cleaning in accordance with
SSPCSP2. Prime the area with BEHR® Interior/Exterior Metal
Primer No. 435 or BEHR® Interior/Exterior Multi-Surface
Stain-Blocking Primer/Sealer No. 436 the same day as cleaned.
Shop-Primed Steel: As there is potential for many forms
of contamination during storage and transport, a thorough
cleaning is always recommended for shop-primed surfaces.
Paint exposed areas, i.e., where shop primer is abraded,
with the same material as used for shop priming to comply
with SSPC-PA 1 for touching up shop-primed surfaces. Note:
Assess the integrity of the shop primer prior to application
of subsequent coatings. Review all coatings intended for the
project and conrm the compatibility between shop and
eld-applied coatings.
Aluminum: Remove all oil and grease from the surface
with a solvent in accordance with SSPC-SP1. Prime the area
with BEHR Interior/Exterior Metal Primer No. 435 or BEHR
Interior/Exterior Multi-Surface Stain-Blocking Primer/Sealer
No. 436 the same day as cleaned.
Stain-Blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before top-coating the entire area. If bleeding
continues, a longer dry time of the primer may be needed
before top-coating.
COMPLIES WITH THE BELOW AS OF 6/1/2020
SCAQMD YES AIM YES
CARB SCM 2007 YES GREENGUARD®
#
YES
OTC Phase II YES LEED® v.4
†
YES
OTC YES CHPS YES
LADCO YES NAHB/ICC NGBS YES
#
GREENGUARD is a registered trademark of UL Company.
†
Please visit www.usgbc.org/LEED for additional details.