TDS

This information is provided “as is” and no representations or warranties, either expressed or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For MSDS or to consult with a Behr Certied Coatings Professional,
call 1-800-854-0133 Ext. 2 (U.S.A. only). ©2020 Behr Process Corporation Santa Ana, CA 92704 U.S.A.
TECHNICAL DATA SHEETTECHNICAL DATA SHEET
Revised 06/2020
MASONRY, STUCCO & BRICK FLAT PAINT
NO. 270 WHITE
1 of 2
PRODUCT INFORMATION
BEHR® Masonry, Stucco & Brick Flat paint is a high-quality, acrylic latex paint with excellent hiding properties.
This interior/exterior, self-priming, mildew resistant finish also provides excellent adhesion and water repellency on
properly prepared, smooth, rough and textured masonry, stucco and brick surfaces. It is alkali-resistant up to pH 12,
easy to apply, and cleans up with soap and water.
RECOMMENDED USES:
This product is ideal for use on properly prepared and primed above grade vertical surfaces such as:
• Concrete • Concrete Block/CMU • Fiber Cement • Stucco
• EIFS • Brick • Drywall
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 270 White 126  oz / 4  oz
No. 272 Deep Base 116  oz / 14  oz
Gloss: 0 – 6 @ 60°
Sheen: 0 – 6 @ 85°
Resin Type: Acrylic
Weight per Gallon: 10.7 lb
% Solids by Volume: 30% ± 2%
% Solids by Weight: 44% ± 2%
VOC: < 50 g/L
Flash Point: N/A
Viscosity: 95 – 105 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.0 mils @ 250 sq ft/gal
Wet: 4.0 mils / Dry: 1.2 mils @ 400 sq ft/gal
Coverage: 250 – 400 sq ft/gal depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: 3/8" – 3/4" nap roller cover, depending on
surface texture.
Airless Spray:
Tip: .015" – .021"
Filter: 60 mesh
Thinning: DO NOT THIN. Product is formulated for use at
package consistency only.
Dry Time: @ 77°F & 50% RH
To Touch: 2 – 3 hours
To Recoat: 4 hours
Full Cure: 2 weeks
Longer dry time may be required in cooler temperatures
and higher humidity.
SURFACE PREPARATION:
All surfaces must be clean, free of dust, chalk, oil, grease,
wax, polish, mold and mildew stains, loose and peeling
paint, rust, and all other foreign substances.
Drywall: All drywall surfaces should be suciently sanded
smooth. Remove any remaining drywall dust prior to
priming. Allow all drywall compounds to be completely dry
prior to coating.
Masonry: All masonry surfaces must be cured at least 30
days before painting. The pH must be 12 or lower prior to
coating. Smooth masonry may require an adequate prole
for adhesion. For all other smooth concrete, create a prole
using a product such as a muriatic acid etcher to achieve a
textured prole. Use a cleaner to remove loose aggregate
and debris.
Wood: Remove mill glaze with sandpaper or use a product
such as BEHR PREMIUM® All-In-One Wood Cleaner No. 63 to
open the pores of the wood and follow all label instructions.
For severe stains caused by mold, mildew, algae and fungus,
apply a mildew stain removing product. Set nails and ll
holes, scratches, and gouges with the appropriate wood
ller and let dry completely. Remove all dust with a wiping
cloth. Fill all gaps with a 100% acrylic, siliconized, paintable
caulking and allow to dry completely. Patched and lled
surfaces should be sanded smooth and dusted clean prior
to coating.
Steel: Minimum surface preparation is Hand Tool Cleaning
in accordance with SSPC-SP2. Remove all oil and grease from
the surface with a solvent in accordance with SSPC-SP1.
For optimal performance, use Commercial Blast Cleaning
in accordance with SSPC-SP6. Prime the area with a
rustinhibitive primer such as BEHR Interior/Exterior Metal
Primer No. 435 the same day as cleaned.
Galvanized Steel: Solvent clean new galvanized metal in
accordance with SSPC-SP1 to remove oil and grease from
the surface. Pre-treat with a phosphoric acid solution or
a commercially-available etching solution. Galvanized
metal that has been passivated with chromates or silicates
may require brush blasting in accordance with SSPC-SP16
to remove these treatments. Rusty galvanizing requires
a minimum of Hand Tool Cleaning in accordance with
SSPCSP2. Prime the area with BEHR® Interior/Exterior Metal
Primer No. 435 or BEHR® Interior/Exterior Multi-Surface
Stain-Blocking Primer/Sealer No. 436 the same day as cleaned.
Shop-Primed Steel: As there is potential for many forms
of contamination during storage and transport, a thorough
cleaning is always recommended for shop-primed surfaces.
Paint exposed areas, i.e., where shop primer is abraded,
with the same material as used for shop priming to comply
with SSPC-PA 1 for touching up shop-primed surfaces. Note:
Assess the integrity of the shop primer prior to application
of subsequent coatings. Review all coatings intended for the
project and conrm the compatibility between shop and
eld-applied coatings.
Aluminum: Remove all oil and grease from the surface
with a solvent in accordance with SSPC-SP1. Prime the area
with BEHR Interior/Exterior Metal Primer No. 435 or BEHR
Interior/Exterior Multi-Surface Stain-Blocking Primer/Sealer
No. 436 the same day as cleaned.
Stain-Blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before top-coating the entire area. If bleeding
continues, a longer dry time of the primer may be needed
before top-coating.
COMPLIES WITH THE BELOW AS OF 6/1/2020
SCAQMD YES AIM YES
CARB SCM 2007 YES GREENGUARD®
#
YES
OTC Phase II YES LEED® v.4
YES
OTC YES CHPS YES
LADCO YES NAHB/ICC NGBS YES
#
GREENGUARD is a registered trademark of UL Company.
Please visit www.usgbc.org/LEED for additional details.

Summary of content (2 pages)