PRODUCT INFORMATION
BEHR PREMIUM® Basement & Masonry Waterproofer with NANOGUARD® Technology, is a premium, interior/exterior
waterproong paint designed for porous concrete and masonry surfaces. This paint is formulated for waterproong above
and below grade basement walls, masonry walls, retaining walls, cinder & concrete blocks, stucco and brick. It uses NANOGUARD
Technology to form a strong waterproof barrier to stop water inltration.
RECOMMENDED USES:
Properly prepared, primed or previously painted interior or exterior, above or below grade:
•Masonry • Concrete Block/CMU • Cement Board Siding
• Concrete •Brick • Stucco
Not for use on oors and walls with active water leaks. Do not use over oil-or latex-based paint.
This product can be used as a water vapor barrier.
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 875 126 oz. / 4 oz.
Pre-Mixed Colors:
No. 876 Basement Gray
Gloss: <5 @ 60°
Sheen: <4 @85°
Resin Type: 100% Styrene Acrylic Latex
Weight per Gallon: 11.9 lbs.
% Solids by Volume: 45.0%
% Solids by Weight: 61.3%
VOC: <100 g/L
Flash Point: N/A
Viscosity: 100-110 KU
Recommended Film Thickness:
1st Coat: Wet: 21.3 Dry: 9.5 mils @ 75 Sq. Ft./Gal.
2nd Coat: Wet: 12.8 Dry: 5.7 mils @ 125 Sq. Ft./Gal.
Coverage: 75-125 Sq.Ft./Gal. depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: See label instruction.
Airless Spray: Fluid pressure, 2,400-3,200 psi
Tip: .023"- .027"
Filter: Remove
Thinning: Do Not Thin. Product is formulated for use at
package consistency only.
Dry Time: @ 77° & 50% RH
Longer dry time may be required in cooler temperatures and
higher humidity.
To Touch: 1 hour
To Recoat: 4 hours
Full Cure: 7-14 days
Need adequate ventilation
SURFACE PREPARATION:
New or Unpainted Surfaces: New concrete must cure for
a minimum of 30 days. Test for loose, aking concrete by
pressing a piece of masking or cellophane tape at various
places, then pull it o with an abrupt action. If the tape does
not pull the concrete from the surface, it can be painted.
If the existing concrete is removed, the loose concrete
should be removed down to a sound substrate.
For below grade application: All holes or cracks must be
properly patched with a fast setting hydraulic cement.
For above grade application: Remove mildew stains
with a mildew stain removing product. All surfaces must
be clean and free of dirt, dust, eorescence and oil. Clean
surface with a product such as a muriatic acid etcher or with
mechanical means. Follow all label instructions.
Previously Painted Surfaces: BEHR PREMIUM
Basement & Masonry Waterproofer provide best results
when applied to bare or untreated surfaces. PREVIOUSLY
PAINTED SURFACES IN GOOD, REPAINTABLE CONDITION MAY
BE PAINTED WITH A PRODUCT SUCH AS BEHR PREMIUM
BASEMENT & MASONRY WATERPROOFER No. 875, HOWEVER,
BEHR WILL NOT GUARANTEE THE RESULTS. Test for loose,
aking paint by pressing a piece of masking or cellophane
tape at various places, then pull it o with an abrupt action.
If the tape does not pull the paint from the surface, it can
be painted. If the existing paint is removed, the loose paint
should be removed down to a sound substrate by wire
brushing or sanding. For Interior or Exterior application;
remove deteriorated coating prior to application.
Follow all preparation instructions under "New or Unpainted
Surfaces" above.
WARNING! If you scrape, sand or remove old paint,
you may release lead dust. LEAD IS TOXIC. Contact the
National Lead Information Center at 1-800-424-LEAD or
visit www.epa.gov/lead.
RECOMMENDED PRIMER/SYSTEMS:
• BEHR PREMIUM Interior/Exterior Basement & Masonry
Waterproofer No. 875 (can also be used as a block ller.)
BEHR PREMIUM PLUS® Interior/Exterior Multi-Surface
Primer & Sealer No. 436
Masonry with pH Levels up to 13.0:
• BEHR PREMIUM Interior/Exterior Basement & Masonry
Waterproofer No. 875.
BEHR PREMIUM PLUS Interior/Exterior Multi-Surface
Primer & Sealer No. 436
PREVIOUSLY PAINTED SURFACES:
• Use a full coat or spot prime with BEHR PREMIUM
Basement & Masonry Waterproofer Paint No. 875
on properly prepared surfaces.
TEST SPECIFICATIONS:
Resistance Wind Driven Rain:
ASTM 6904/TTC55B- Pass
Resistance to Hydrostatic Pressure:
ASTM D 7088/ 12 Psi
Blistering: ASTM D 714/No Blisters
PERM: Water Vapor Permeability: Test Method: ASTM E-96/
ASTM D-1653 Result-<1 US PERMS
1 of 2
BASEMENT & MASONRY WATERPROOFER
NO. 875
COMPLIES WITH THE BELOW AS OF 5/1/2016
SCAQMD YES LADCO YES
CARB YES AIM YES
OTC YES LEED v.3 (2009)
YES