Table of Contents Device description................................................................................................ 6 Apperance ...................................................................................................................................... 6 Technical parameters...........................................................................................7 Main features ......................................................................................................
Open lock...................................................................................................................................................................... 25 Additional settings .................................................................................................................................................... 25 Server manage access ............................................................................................................................................
Recieving the RTSP stream from the panel's camera ..................................................
Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Device description(see page 6) Technical parameters(see page 7) Configuration through graphical interface(see page 8) Configuration trough web interface(see page 15) Installation and connection(see page 41) Device usage(see page 47) ĵ 5
Device description Modern design and well-thought out functionality of this panel makes it an ideal solution for business and elite buildings. AA-12ɬB is available in gold, silver, and black, and also it supports BAS-IP UKEY mobile access. There is a separate button to call concierge or emergency services.
Technical parameters Main features Panel type:bMulti apartment Screen:b4,3 TFT, color with backlight Camera:b1/4, camera direction adMustment Angle:b117r hori]ontal xb 62r vertical Camera resolution:b1 MP Output Video:b+D (1280x720), +.
Configuration through graphical interface Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Main screen(see page 8) Device settings(see page 9) Network settings(see page 11) Access settings(see page 12) Additional settings(see page 13) About system(see page 14) Main screen Call: to call the apartmentb required, you need to enter from 4 to 10 digits depending on the current mode of the panel.b Concierge: to call concierge you should enter 0000 bor press separate call button on the keypad.
Apartments are sorted by name. The address book is opened by clicking on the arrow buttons orb bandbcall is made by pressing the " ". The exit to the main screen is carried out by pressing " ʧ " or automatically, after 30 seconds of inactivity. By default, address book is disabled. The tips displayed on the main screen can be changed in the "Advanced Ĺ Custom Notifications2"bsection.
The "2" button moves the cursor up, the "8" button moves the cursor down. To confirm the values, press the " " button and the " ʧ " button to go back.b Mode: select operation mode of the panel.
Information about operation modes If you select the "Wall" mode, you must enter 4 digits of the building number, 2 digits of the unit number, 2 digits of the floor number, and 2 digits of the apartment number to call the desired monitor.b If you select the "Unit" mode, youbmust enter only 2 digits of the floor number andb2 digits of the apartment number to call the desired monitor.bb You shouldn't select individual opreration mode for these panels. It is used only for individual panels.
DHCP: Enable/disable mode to get network settings automatically. IP: IP address ofboutdoor panel. By default the outdoor panel can have a static IP address 192.168.68.90 or 192.168.1.90. Mask: Subnet mask. Gateway: Default gateway. DNS: Address of the DNS server. Server:bIP address of your PC or server, where Management Software or Link software is installed.
Timeout: Time when contacts of the panel relay will be closed or open. Delay: Time after which contacts of the panel relay will be closed or open (delay before unlocking). Elev Refer: Floor number where the panel is installed (using elevator control module EVRC-IP, optional). Password: Password to open the lock by entering the unlocking code on the panel keypad. To enter the password input mode, press the " " key, type the password and press " " again.
RoomNum: Apartment number to which access card must be linked. Adding cards through graphical interface: Enter the desired apartment number and wave the card in front of the area of the reader. A signal will sound from the panel, confirming that the card is registered, and a card number will be displayed in thebCard field. Reboot:bRestart outdoor panel. To restart outdoor panel, it is necessary to enterb" ", pressb"1", and then pressb " " again. Default: Reset panel settings to factory settings.
Configuration trough web interface Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Ŀ Login(see page 15) Dashboard(see page 16) Network(see page 17) Panel(see page 18) Apartments(see page 21) Access management(see page 23) Ŀ Identifiers(see page 26) Ŀ Access restrictions(see page 27) Forward(see page 30) Advanced(see page 32) Logs(see page 36) Security(see page 36) System(see page 37) Login To configure the outdoor panel remotely through the Web-interface, you need to connect to it via an internet browser on the PC.
Dashboard After successful authorization, the following interface will be displayed: Framework: Firmware version. Launcher: Launcher version. Hybrid Mode: The current connection mode of the hybrid adapter. Hybrid Version: Hybrid adapter version. Serial number:bSerial number of the device. Device name: Name of the device.
Network information DHCP: The current state of the DHCP connection. IP Address: The current IP address of the panel. Subnet Mask: Subnet Mask. Gateway Address: The address of the main gateway. DNS server: DNS server address. MAC address: MAC address of the panel. Network Network settings DHCP:bEnable/disable mode to get network settings automatically.b IP:bOutdoor panel IP address. Default values By default, the outdoor panel can have a static IP address 192.168.1.90 or 192.168.1.91. Mask: Subnet Mask.
DNS: DNS server address. Custom NTP NTP: Enable/disable the use of a custom NTP server. URL: The input field for the user NTP server address. Time Zone: Select the time zone. Management system Mode: Selects the operation mode of the panel control system. URL: Management server address. Password: Access password. Send realtime logs to server: Enable/disable panel logging to server. Send status to server: Enable/disable sending current panel status to server.
Information about operation modes If you select the "Wall" mode, you must enter 4 digits of the building number, 2 digits of the unit number, 2 digits of the floor number, and 2 digits of the apartment number to call the desired monitor.b If you select the "Unit" mode, youbmust enter only 2 digits of the floor number andb2 digits of the apartment number to call the desired monitor.bb Building:bNumber of the building. Unit:bUnit number. Device number:bDevice number of the outdoor panel.
Example: stun.l.google.com. STUN port: The port of the STUN server. Example: For google STUN server 19302 port is used. Password: Password of SIP number. Call settings Concierge: Enable / disable the function to call the specified number in the "Number" line when pressing the concierge button. Number: The direction to which the call will be made when pressing the concierge button. If the function is not enabled, the concierge is called via an internal protocol.
Video quality: Select your preferred video resolution. RTP data profile: Select your preferred RTP data profile. Volume Level: Adjusts the speaker volume of the panel. RTSP username: Login to get access to RTSP stream. RTSP password:bPassword to get access to RTSP stream. Approximation sensor: Enable/disable the approximation sensor, which turns on the keyboard backlight when triggered. Apartments This menu displays a list of apartments.
New apartment After clicking on the "New apartment" button, the following interface will be displayed: Building: Building number 0001-9999 Unit:b Unit number: 00-99 Floor:b Floor number: 00-99 Apartment: Apartment number: 01-99 Apartment name: Apartment name. For example, "Smith's" Number of inhabitants: The conditional number of inhabitants who live in this apartment.
The table contains the following columns: Apartment name: Apartment name. Number of inhabitants: The conditional number of inhabitants in this apartment. Number of identifiers: The number of identifiers that are issued for this apartment. Identifiers can be created in the "Access management" menu, tab "Identifiers". Number of access codes: The number of access codes issued for this apartment. Number of redirects: The number of redirects configured for this apartment.
Common settings Master card: Master card number. Use master code: Enable/disable using master code to open the lock. Master code: The code entered on the keypad for opening the lock. When using the control module with two locks SH-42, when entering the master code on the panel, both locks will open.
Lock #1, Lock #2 Lock open time (s): Time for which the panel relay contacts are closed or open. Delay before opening: Time after which the contacts of the panel's relay will close or open. Open lock Lock #1, Lock #2 Open lock: The function of opening the selected lock from the panel WEB interface.
Server manage access Enabled: Turning on/off the panel operation mode, in which access cards and identifiers are not stored in the panel's memory and when placed to the reader, the panel will send a request to the server and wait for the answer - to give access or not. Use a custom server: Enable/disable the use of custom server to control the panel. Custom server server: The custom server URL address.
Apartment number: Select an apartment from the existing list of apartments. Name of the owner: Information about the owner of the identifier. Owner Type: Select the type of owner ID. The Owner and Guest types are available. Identifier Type: Select identifier Type. There are 3 types of identifiers available: Card - EM-Marin or Mifare card. In the next field "ID number" you must enter the ID number in decimal format, without comas. This ID usually is printed on the card.
New restriction After clicking on the "New restriction" button, the following interface will appear: Name: The name of the rule. All day: Enable/disable the time restriction interval per day.
If function is disabled, user can set time interval of this restriction. Start at - End at: Select the interval of action for this restriction. Repeat:bSpecify the duration of repetitions of this restriction.
Duration of repetitions: Select the number of repetitions of this restriction. If you select the "Infinitely" option, rule will always act. If you select the "Until" option, you can set the end date for the action of this restriction. Forward This section is used to substitute numbers by panel when making calls to internal monitors when there is no monitor or it is turned off, or to any given SIP number.
Mode: Mode of the forwarding. All at once - the call is made to all numbers simultaneously.b One by one - the call is made to the numbers in turn with a delay of 20 seconds. New forward queue After clicking on the "New Forward" button, the following interface will be displayed: Apartment number: Number dialed on the panel's keypad.
Forward Number: The direction in which the call will be made when you enter the corresponding number on the keypad. It can be used both for calls within the LAN via P2P, and for SIP calls. Input format for internal calls sip:1@192.168.1.65, where 1 is the desired number to be displayed by the called party, 192.168.1.65 is the IP address of the called SIP client (in the case of using a softphone, the IP address of the device where the softphone is installed). Call to SP-02: sip:192.168.1.99, where 192.168.1.
During a call, it is possible to switch between streams by pressing keys from 1 to 5 in the monitor menu. The key "1" corresponds to the stream of the outdoor panel, the keys from "2" to "5" - to additionally added streams (transmission is carried out by DTMF RFC2833). URL:bURL of the RTSP stream which could be displayed during a call. Example: rtsp://admin:123@192.168.1.189:8554/ch01 Custom notifications Window for editing user notifications for various actions.
Required audio file options Ŀ Ŀ Ŀ Ŀ Format: wav Channels: mono Bit rates: 16 Sample Rate: 8000 Hz Key pressing: Sound when you press the panel keys. Message text: The text displayed on the main panel screen. In this field you can enter, for example, the number of the concierge for communication or the name of the residential complex.
Ring back:bSound and text messageb"Calling" when panel make an outgoing call. Door unlock: Sound and the text message "Welcome" when panel receive a signal to open the lock. Error:bbbSound and text messageb"Error"bwhen entering an unregistered subscriber number, the lock opening code and the presentation of an unregistered identifier.
Emergency: Sound and text alert "Alarm!" when switching the panel to emergency mode. Switching occurs programmatically through BAS-IP Link or through third-party software using API. In emergency mode, locks connected to the panel are also opened. If any of the functions is turned off, the standard sound and the standard text message will be used. Logs In this section all actions what happened with a panel are displayed. Security In this section you can can change admin and manager password.
Administrator - has full access to all panel settings. Manager - has access to the panel settings, but he has limited access to the access control menu. Typically, access to this account is provided to installers to install and configure the system. The manager can only change the manager's password. The administrator can change the manager password and the administrator password. Old password: The field to enter the current password. The default administrator password is 123456.
Settings Choose file:bSelecting the panel configuration file from the PC file system. Set default settings: Reset all panel settings to factory defaults. Backup all settings: Save and export configuration files.
Choose file: Choosing the path to the backup file in te PC's filesystem. When importing data into the panel, all data in the Apartments, Forward, Identifiers and Access restricitons tables will be deleted and replaced with new data without the possibility of restoring old data. Export data: Makes an export of time profiles, identifiers, forwards and apartments data.
Use custom server:bEnable/disable use of custom update server. Used in closed intercom networks. Custom server: The input field for the IP address or domain of the custom update server. Select file: Select software update file from PC file system. After selecting the file, you must click on the "Update Software" button. Check for update: Check for software update on BAS-IP server or user server. Update software: Start software update.
Installation and connection This page describes the process of installation and connection of the outdoor panel. Ŀ Ŀ Ŀ Ŀ Completeness check of the product(see page 41) Electrical connection(see page 41) Mechanical mounting(see page 45) Connection of additional modules(see page 46) Completeness check of the product Before installation of the outdoor panel, it is necessary to check that it is complete and all components are available.
1. Connection scheme of electromagnetic lock using uninterruptible power supply UPS-DP-S. 2.bConnection scheme of electromagnetic lock using third-party power supply for the lock.
3. Connection scheme of electromechanical lock using uninterruptible power supply UPS-DP-S.
3.bConnection scheme of electromechanical lock using third party power supply for the lock.
Mechanical mounting Before installation of the outdoor panel it is necessary to provide a hole or a recess into a wall with dimensions 141×359×58bmm (for flush mount) dimensions of the bracket (mounting box) 140×358×57bmm. It is also necessary to provide supply of a power cable, additional modules and the local network.
Installation height recommendations: The outdoor panel should be installed at a convenient height for you. Approximate height of installation is 160-165 cm of the camera level.
Device usage Ŀ UKEY mobile access(see page 47) Ŀ Recieving the RTSP stream from the panel's camera(see page 51) UKEY mobile access Description Ukey Mobile Access from BAS-IP is a universal technology for gaining access to the premises or to the territory of an object with the possibility to use in one reader simultaneously: EM-Marin cards and MIFARE/encrypted cards MIFARE Plus/MIFARE Classic, cell phone (Bluetooth and NFC).
For users' ease of operation with BAS-IP outdoor panels equipped with multi-format readers, the company BAS-IP has released a new mobile Ukey application which, after receiving the mobile ID, is used to open the doors/gates/parking gate arms.b For each outdoor panel equipped with a reader module with support for UKEY Mobile access, a different range of the mobile ID can be configured, in the range of 2 centimeters to 10 meters.
user gets the QR-code in the printed form or in electronic form (by e-mail, Viber, Telegram, etc.). Then the user scans the code received or imports it from the file system and thus gets the mobile ID.b Before the identifier is issued to the user as a QR-code, it is recorded by the administrator of the management company in the Management Software.
2. bInstall and launch the program on a PC with the Windows Family OS to write the identifiers "BAS-IP USB Reader Server";b 3. Connect the reader to PC; 4. Bring a master-card to the reader; 5. Bring a cell phone to the reader (make sure Bluetooth is on) and enter UKEY App, then press Obtain button or select Obtain BAS-IP TR-03 key.b 6. The reader will transmit a mobile ID to your cell phone, thus "Your key is ready" will appear in the app.
Recieving the RTSP stream from the panel's camera To get the RTSP stream from the camera of the call panel to the video surveillance system, you need to put in the add line of the camera rtsp://admin:123456@192.168.1.16:8554/ch01, where admin is the login, 123456 is the password to access the WEB interface, 192.168.1.16 is the IP address of the panel, 8554 is the port of access to the camera, ch01 is the channel number.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.